Predictika · Plate handoffs between lab instruments by an AI lab-automation agent

An AI lab agent's plate handoff between instruments, checked before the arm moves

An AI lab-automation agent moves a microplate from one instrument to the next with the cell's robot arm, using what the lab's instruments report: the liquid handler head, the doors, whether the reader is ready, the plate's lid, seal and format, and the incubation clock. Before the arm moves, the agent sends the handoff to Predictika, which checks it against a declarative model of what those records say and returns a verdict, every reason and the figures it computed.

Scope: Moving one microplate between a liquid handler, an incubator, a plate reader and a centrifuge with one robot arm: the state of both instruments, the plate, the assay timing and the biosafety approvals. See everything this validator covers

This validator models one plate handoff in a fictional automated assay lab, not just the scenarios shown below. The lab, its instruments and its rules are fictional stand-ins for what a real lab keeps in its instrument manuals, assay protocols and biosafety procedures. Each instrument keeps its own limits; this checks what no single instrument knows. It is an example policy, not a safety certification.

  • Both instruments, together — the liquid handler head must be parked before the arm reaches in; the destination door must be open and the plate reader ready; a handoff from an instrument to itself is refused.
  • The plate for this destination — the reader needs the lid off; the centrifuge takes 96-well plates only, sealed, with a balance plate loaded opposite.
  • Assay timing at the reader — a BCA plate needs 30 minutes of incubation and a read within 10; a viability plate needs 60 and a read within 15. The reader stacker holds four plates; a handoff into a stacker that already holds three goes to a lab technician.
  • Biosafety and exposure — an open plate of human-derived sample moving by arm goes to the biosafety officer; a plate open past 15 minutes goes to the lab supervisor; a plate open past 30 minutes is blocked because the samples evaporate. The wait the agent states is compared with the lab clock.

Any handoff of one plate between these four instruments is in scope — not only the scenarios pictured here. Not covered: scheduling across plates, protocol design, other instruments, and each instrument's own safety interlocks, which stay with the instrument. All instruments, limits and rules are fictional.

The AI lab-automation agentDecides the next handoff and asks the arm to move the plate from the instruments' reports, and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

6 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI lab-automation agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI lab-automation agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where a per-instrument check gets it wrong

Click to expand

Our assessment of what each instrument's own limit check, plus the lab scheduler's validation rules, does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical per-instrument checkPredictika
The other instrument's stateOnly with workarounds
The handler knows its head is over the deck and the reader knows it is not ready, but neither knows the other is waiting on it. The check has to live in the scheduler, which reads both.
Source, destination and arm are checked together on every call.
What the plate needs for this destinationOnly with workarounds
Lid off for the reader; sealed, 96-well and a balance plate for the centrifuge. The needs change with the destination, so each is a separate rule keyed on it.
The plate's lid, seal, format and balance are checked against the destination in one pass.
Timing that depends on the assayOnly with workarounds
A BCA plate needs 30 minutes and a read within 10; a viability plate needs 60 and 15. A fixed limit per instrument cannot say that; it takes a rule per assay.
The incubation and read window are looked up for this assay and compared with the lab clock.
The wait the agent statesOnly with workarounds
The figure an agent writes in a handoff never reaches a check in the scheduler; nothing compares it with the lab clock.
The stated wait is a field the validator receives and compares with its own.
A fix that opens the next problemOnly with workarounds
Sealing an open plate clears the centrifuge finding and the open-plate approvals, but a 384-well plate still has to be re-plated and a balance plate loaded. A check that runs as the step is saved shows one at a time.
The corrected handoff is checked as a whole, so the fix is checked, not just the last error.
Approvals that go to different peopleOnly with care
An open plate of human-derived sample goes to the biosafety officer, a plate open too long to the lab supervisor, a nearly full stacker to a technician. Someone has to route each.
Each approval is its own finding, with the reason, and a person must approve before the arm moves.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the step is saved, so the agent fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the handoff; approval findings need a person to sign off; everything else is computed.

1The plate is being moved from an instrument to itself.
2The liquid handler head is still over the deck; the arm cannot reach in without a collision.
3The destination door is closed; the arm cannot place the plate until it is open.
4The plate reader is not ready (still warming up or not calibrated); it cannot accept a plate yet.
5The centrifuge rotor takes 96-well plates only; this is a 384-well plate.
6The plate reader needs the lid removed; this plate still has its lid on.
7A plate must be sealed before it goes into the centrifuge; this one is open.
8The centrifuge needs a balance plate loaded opposite; none is present.
9The plate has incubated 29 minutes; this assay needs 30 before it can be read.
10The plate has waited 11 minutes since incubation ended; this assay must be read within 10 minutes.
11The plate has been open for 31 minutes; past 30 minutes the samples evaporate.
12The plate has been open for 31 minutes, past the 15 minutes a technician may leave it; the lab supervisor approves moving it.
13The arm would carry an open plate of human-derived sample; the biosafety officer approves.
143 plates are already waiting at the reader, which holds 4; the lab technician confirms there is room.
15The reader stacker already holds 4 plates, which is its limit of 4.
16The request states the plate has waited 3 minutes since incubation ended, but the lab clock gives 5 minutes.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Centrifuge: Human-derived 384-well plate from the incubator to the centrifuge

The agent's request. Please move a BCA protein assay 384-well plate of human-derived sample from the incubator to the centrifuge. The plate is delidded and unsealed, open for 20 minutes. The centrifuge door is open. No balance plate is loaded. Incubation ran from minute 0 to minute 35 and the lab clock reads minute 40. The handoff states the plate has waited 5 minutes since incubation ended. It is ready to go.

Verdict: Blocked.

  • 384-well plate into the centrifuge. The centrifuge rotor takes 96-well plates only; this is a 384-well plate.
  • Unsealed plate into the centrifuge. A plate must be sealed before it goes into the centrifuge; this one is open.
  • No balance plate for the centrifuge. The centrifuge needs a balance plate loaded opposite; none is present.
  • Open plate of human-derived sample. The arm would carry an open plate of human-derived sample; the biosafety officer approves.
  • Plate open longer than a technician may leave it. The plate has been open for 20 minutes, past the 15 minutes a technician may leave it; the lab supervisor approves moving it.

2. Centrifuge: The agent resubmits after fixing the errors

The agent's request. Please move a BCA protein assay 96-well plate of human-derived sample from the incubator to the centrifuge. The plate is delidded and sealed. The centrifuge door is open. A balance plate is loaded. Incubation ran from minute 0 to minute 35 and the lab clock reads minute 40. The handoff states the plate has waited 5 minutes since incubation ended. It is ready to go.

Verdict: Allowed.

  • Run summary. 35 minutes of incubation against 30 required; 5 minutes since incubation ended against a 10 minute read window.

3. Plate reader: BCA protein assay plate from the liquid handler to the plate reader

The agent's request. Please move a BCA protein assay 96-well plate of reagent-only sample from the liquid handler to the plate reader. The plate is lidded and unsealed, open for 10 minutes. The liquid handler head is over the deck. The plate reader door is closed. The plate reader is not ready. Incubation ran from minute 0 to minute 18 and the lab clock reads minute 24. The reader stacker holds 1 plate. The handoff states the plate has waited 6 minutes since incubation ended. It is ready to go.

Verdict: Blocked.

  • Liquid handler head still over the deck. The liquid handler head is still over the deck; the arm cannot reach in without a collision.
  • Destination door closed. The destination door is closed; the arm cannot place the plate until it is open.
  • Plate reader not ready. The plate reader is not ready (still warming up or not calibrated); it cannot accept a plate yet.
  • Lid still on for the plate reader. The plate reader needs the lid removed; this plate still has its lid on.
  • Read before incubation is complete. The plate has incubated 18 minutes; this assay needs 30 before it can be read.

4. Plate reader: The agent resubmits after fixing the errors

The agent's request. Please move a BCA protein assay 96-well plate of reagent-only sample from the liquid handler to the plate reader. The plate is delidded and unsealed, open for 10 minutes. The liquid handler head is parked. The plate reader door is open. The plate reader is ready. Incubation ran from minute 0 to minute 34 and the lab clock reads minute 40. The reader stacker holds 1 plate. The handoff states the plate has waited 6 minutes since incubation ended. It is ready to go.

Verdict: Allowed.

  • Run summary. 34 minutes of incubation against 30 required; 6 minutes since incubation ended against a 10 minute read window.

5. Late read: Viability plate from the incubator to a full plate reader

The agent's request. Please move a cell viability assay 96-well plate of reagent-only sample from the incubator to the plate reader. The plate is delidded and unsealed, open for 8 minutes. The plate reader door is open. The plate reader is ready. Incubation ran from minute 0 to minute 65 and the lab clock reads minute 90. The reader stacker holds 4 plates. The handoff states the plate has waited 10 minutes since incubation ended. It is ready to go.

Verdict: Blocked.

  • Read window already missed. The plate has waited 25 minutes since incubation ended; this assay must be read within 15 minutes.
  • Reader stacker is full. The reader stacker already holds 4 plates, which is its limit of 4.
  • Stated wait differs from the lab clock. The request states the plate has waited 10 minutes since incubation ended, but the lab clock gives 25 minutes.

6. Late read: The agent resubmits after fixing the errors

The agent's request. Please move a cell viability assay 96-well plate of reagent-only sample from the incubator to the plate reader. The plate is delidded and unsealed, open for 8 minutes. The plate reader door is open. The plate reader is ready. Incubation ran from minute 0 to minute 65 and the lab clock reads minute 77. The reader stacker holds 3 plates. The handoff states the plate has waited 12 minutes since incubation ended. It is ready to go.

Verdict: Needs approval.

  • Reader stacker nearly full. 3 plates are already waiting at the reader, which holds 4; the lab technician confirms there is room.
  • Run summary. 65 minutes of incubation against 60 required; 12 minutes since incubation ended against a 15 minute read window.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI lab-automation agent moves a microplate from one instrument to the next with the cell's robot arm, using what the lab's instruments report: the liquid handler head, the doors, whether the reader is ready, and more. Before the arm moves, the agent sends the handoff to Predictika, which checks it against a declarative model of what those records say and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please move a BCA protein assay 384-well plate of human-derived sample from the incubator to the centrifuge. The plate is delidded and unsealed, open for 20 minutes. The rest of the request is on screen. The handoff states the plate has waited 5 minutes since incubation ended.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with three findings and two approvals, all in one answer. The centrifuge rotor takes 96-well plates only; this is a 384-well plate. A plate must be sealed before it goes into the centrifuge; this one is open. The centrifuge needs a balance plate loaded opposite; none is present.
  6. The validator returned three blocking findings and two approvals in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the handoff are checked against each other.
  7. What this shows: for what the plate needs for this destination, a per-instrument check can do this only with workarounds.
  8. Now the agent resubmits.
  9. The corrected request. It changes the plate format to 96-well, the seal to sealed and the balance plate to present.
  10. It calls the validator again.
  11. This time the validator clears it.
  12. All five earlier findings are cleared, and the validator's figure matches the handoff.
  13. Five problems caught in one call, fixed in one pass, and a clean handoff. That is the value of Predictika's validator: catching mistakes before the arm moves. Now you can try the other scenarios yourself.