Predictika · Test and measurement power
An AI sales agent configures a Sequoia Series regenerative grid simulator for a test lab: the chassis model and how many are combined, the input voltage, output voltage range, frequency, interface, test and hardware options, the power, voltage, frequency and feeder the customer needs, the site conditions, and the total power it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures in the public data sheet and returns a verdict, every reason and the figures it computed.
This validator models one Sequoia Series configuration at a time, based on the public Sequoia Series data sheet (rev. 2024.06.18), not just the scenarios shown below.
Any Sequoia Series configuration that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (AMETEK does not publish list prices, so this page shows no price build-up), other AMETEK product lines, the full ordering part number, support terms, and real-world performance, which depends on the application.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Option availability that depends on the chassis model | Only with workarounds Input voltages, output ranges and the chill door are each available on some chassis models and not others, so a rules-based CPQ needs a compatibility table or one rule per option and model pair. | Model and options arrive in one request and every availability rule is checked on every call. |
| Power that adds up across chassis, with a model-specific limit | Only with care Total power is a per-chassis figure times a count, compared with the requirement and with a maximum that differs by model. | The total, the requirement and the limit are computed together on every call. |
| Voltage and frequency needs against the selected options | Only with care The highest voltage and frequency depend on which range and frequency options were chosen, and electronic load mode adds a lower limit. | The highest available value is derived from the selected options and compared with the need. |
| Feeder current from a model and input voltage table | Only with care The line current comes from a table with one row per model and one column per input voltage, some combinations being unavailable. | The table lookup and the comparison with the feeder happen in the same request. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the configuration is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The selected input voltage is not offered on this model; 208 V and 230 V are not available on the SQ90, and 380 V is not available on the SQ15. |
| 2 | The Sequoia 15 (SQ0015) is listed with 1 phase output only; the quote needs 3 phases. |
| 3 | The data sheet limits multi-chassis maximum power to 270 kVA with the SQ45 (6 chassis) and 1.08 MVA with the SQ90 (12 chassis); the quote has 7 chassis. |
| 4 | The data sheet limits multi-chassis maximum power to 270 kVA with the SQ45 (6 chassis) and 1.08 MVA with the SQ90 (12 chassis); the quote has 13 chassis. |
| 5 | The quote has 0 chassis; at least 1 is needed. |
| 6 | The quote needs 30,000 VA; the chassis give 0 VA in total. |
| 7 | The quote needs 31,000 VA; the chassis give 30,000 VA in total. |
| 8 | The XVC555 and XVC721 output ranges are available only on Sequoia 90 configurations. |
| 9 | The quote needs 400 V line to neutral; the highest range of the selected configuration is 333 V. |
| 10 | The quote needs 441 V line to neutral; the highest range of the selected configuration is 440 V. |
| 11 | The quote needs 400 Hz; the selected frequency option goes up to 100 Hz. |
| 12 | The quote needs 1000 Hz; the selected frequency option goes up to 905 Hz. |
| 13 | In electronic load mode the frequency range is limited to 550 Hz with the HF and EHF options; the quote needs 600 Hz. |
| 14 | The chill door option is available only on Sequoia 90 configurations. |
| 15 | Each chassis draws up to 50 A at the lowest input voltage; the feeder allows 49 A. |
| 16 | The room temperature of 41 degrees Celsius is above the 40 degree operating limit. |
| 17 | The data sheet specifies operation below 2000 meters; the site is at 2000 meters. |
| 18 | The quote states 60,000 VA in total; the chassis give 30,000 VA. |
| 19 | The data sheet lists separate multi-chassis (-MC) codes for the interface, regulatory test and power quality test options; a person should confirm which code applies to this multi-chassis quote. |
| 20 | The data sheet gives multi-chassis maximum power only for the SQ45 and SQ90; a person should confirm 2 chassis of this model with AMETEK. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 2 Sequoia SQ45 chassis with the XVC555 output range on a 480 V input for a lab that needs 90 kVA, 555 V line to neutral, 60 Hz and 3 phases. The feeder allows 70 A for each chassis, the room is at 25 degrees Celsius and the site is at 300 meters. The quote states 90,000 VA of power in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 Sequoia SQ90 chassis with the XVC555 output range on a 480 V input for a lab that needs 90 kVA, 555 V line to neutral, 60 Hz and 3 phases. The feeder allows 200 A for each chassis, the room is at 25 degrees Celsius and the site is at 300 meters. The quote states 90,000 VA of power in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 2 Sequoia SQ45 chassis with the AVSTD power quality test option on a 480 V input for a lab that needs 90 kVA, 277 V line to neutral, 400 Hz and 3 phases. The feeder allows 100 A for each chassis, the room is at 24 degrees Celsius and the site is at 120 meters. The quote states 90,000 VA of power in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 Sequoia SQ45 chassis with the HF frequency option, AVSTD power quality test option on a 480 V input for a lab that needs 90 kVA, 277 V line to neutral, 400 Hz and 3 phases. The feeder allows 100 A for each chassis, the room is at 24 degrees Celsius and the site is at 120 meters. The quote states 90,000 VA of power in total. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 1 Sequoia SQ90 chassis with the HF frequency option, AVSTD power quality test option on a 480 V input for a lab that needs 90 kVA, 277 V line to neutral, 400 Hz and 3 phases. The feeder allows 200 A for each chassis, the room is at 24 degrees Celsius and the site is at 120 meters. The quote states 90,000 VA of power in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 Sequoia SQ90 chassis on a 230 V input for a lab that needs 90 kVA, 277 V line to neutral, 60 Hz and 3 phases. The feeder allows 200 A for each chassis, the room is at 25 degrees Celsius and the site is at 300 meters. The quote states 90,000 VA of power in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 Sequoia SQ90 chassis on a 480 V input for a lab that needs 90 kVA, 277 V line to neutral, 60 Hz and 3 phases. The feeder allows 200 A for each chassis, the room is at 25 degrees Celsius and the site is at 300 meters. The quote states 90,000 VA of power in total. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.