Predictika · Programmable DC power supplies for test benches
An AI sales agent prepares an order for Sorensen SG Series programmable DC power supplies for a test bench. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the SG Series datasheet and returns a verdict, every reason and the figures it computed.
This validator models orders for the Sorensen SG Series as listed in the public SG Series datasheet, not just the scenarios shown below.
Any order for these products that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none are modeled, so there is no price build-up or line-item quote), the 800 V models, other AMETEK Programmable Power product lines, and any change AMETEK has made to the SG Series since the 2011 datasheet.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A 6U chassis ordered at a voltage where only paralleled 3U supplies reach that power | Only with care The single-chassis table has gaps at 10 to 50 V, so every voltage and power step needs its own availability row. | Voltage and power step are compared with the datasheet table on every call. |
| Options that depend on the chassis, the control type or the input voltage (dust filter, 400 Hz, shaft locks) | Only with care Each option has its own exclusion by chassis or control, so the rules multiply and are easy to miss. | Every option is compared with the chassis, control and input choice on every call. |
| Total power and current stated by the agent that do not equal units times the datasheet figures | Only with workarounds The stated figure is usually free text or a separate field, so it takes an extra rule that multiplies and compares. | The stated figures are part of the request and are compared with the computed figures on every call. |
| A test load the order cannot deliver at the site altitude | Only with workarounds Needs a derating calculation outside the product rules. | Voltage, current and power need are checked together with the altitude derating on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the order; approval findings need a person to sign off; everything else is computed.
| 1 | The datasheet gets this voltage and power in a 6U chassis only by paralleling 3U supplies, so it is not offered as a single unit. |
| 2 | 120 V is not a voltage rating this validator covers; SG ratings modeled are 10, 15, 20, 30, 40, 50, 60, 80, 100, 160, 200, 250, 330, 400 and 600 V. |
| 3 | The power size step 7 is not one of the six steps (one to six power modules) of the SG series. |
| 4 | 6 units in parallel; the datasheet allows up to 5 (contact the factory for more). |
| 5 | 3 units in parallel need one paralleling cable per unit, but the order has 2 cable(s). |
| 6 | The order has 1 paralleling cable(s) for a single unit. |
| 7 | 3 units in series; the datasheet allows up to 2. |
| 8 | The negative terminal would float 350 V from chassis potential; the datasheet allows within 300 V. |
| 9 | The output floats 200 V from chassis potential and the datasheet recommends the isolated analog interface (option 1D); the customer must confirm. |
| 10 | The shaft locks option (1E) is for the SGA series only. |
| 11 | The factory-installed front panel dust filter (AJ) is for 3U units only. |
| 12 | 400 Hz input is standard on 3U units; the CV modification applies to 6U units only. |
| 13 | The CV modification (400 Hz input) means the unit does not carry CE, CSA or UL marks; the customer must accept that. |
| 14 | The CV modification is 400 Hz AC input at 208 VAC, which needs input option C. |
| 15 | Passive power factor correction (PF) is for 40 V and 60 V to 600 V models; it is already included on 10 V to 30 V and 50 V models. |
| 16 | 3U rack slides (K550,212-01) fit the 5, 10 and 15 kW models, not the 6U chassis. |
| 17 | 6U rack slides (K550,213-01) fit the 20, 25 and 30 kW models, not the 3U chassis. |
| 18 | The test needs 120 V but the supply is rated 100 V. |
| 19 | The test needs 200 A but 1 unit(s) of this model give 150 A in total. |
| 20 | The test needs 14,000 W but the supply gives 12,000 W after a 20 percent altitude derating. |
| 21 | The datasheet lists operation at 0 to 50 degrees C; the site is at 55 degrees C. |
| 22 | The order states 20 kW in total, but 1 unit(s) of 15 kW give 15 kW. |
| 23 | The order states 160 A in total, but 1 unit(s) of 150 A give 150 A. |
| 24 | The output floats 100 V from chassis potential and the datasheet recommends the isolated analog interface (option 1D); the customer must confirm. |
| 25 | 0 units in parallel; the datasheet allows up to 5 (contact the factory for more). |
| 26 | The test needs 100 A but 0 unit(s) of this model give 0 A in total. |
| 27 | The test needs 8,000 W but the supply gives 0 W after a 0 percent altitude derating. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote two Sorensen SGI supplies, 330 V and 30 kW each, with input option E (396 to 528 VAC) and Ethernet and RS-232C, with the 400 Hz input modification, with 2 paralleling cables. The test needs 300 V and 170 A at a site of 3,000 feet. Together they give 60 kW and 182 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote two Sorensen SGI supplies, 330 V and 30 kW each, with input option E (396 to 528 VAC) and Ethernet and RS-232C, with 2 paralleling cables. The test needs 300 V and 170 A at a site of 3,000 feet. Together they give 60 kW and 182 A. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote one Sorensen SGI supply, 10 V and 16 kW each, with input option D (342 to 440 VAC) and no remote option. The test needs 8 V and 1,500 A at a site of 1,000 feet. Together they give 16 kW and 1,600 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote two Sorensen SGI supplies, 10 V and 8 kW each, with input option D (342 to 440 VAC) and no remote option, with 2 paralleling cables. The test needs 8 V and 1,500 A at a site of 1,000 feet. Together they give 16 kW and 1,600 A. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote one Sorensen SGA supply, 200 V and 15 kW each, with input option D (342 to 440 VAC) and no remote option, with the output floating 400 V from chassis. The test needs 150 V and 60 A at a site of 1,000 feet. Together they give 15 kW and 75 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote one Sorensen SGA supply, 200 V and 15 kW each, with input option D (342 to 440 VAC) and no remote option, with the output floating 250 V from chassis. The test needs 150 V and 60 A at a site of 1,000 feet. Together they give 15 kW and 75 A. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote one Sorensen SGI supply, 100 V and 15 kW each, with input option D (342 to 440 VAC) and no remote option. The test needs 100 V and 130 A at a site of 9,000 feet. Together they give 15 kW and 150 A. It is ready to send.
Verdict: Blocked.
The text of the narrated walkthrough, step by step.