Predictika · Analytical instrument system quotes
An AI sales agent prepares a quote for a liquid chromatography / mass spectrometry system: LC module, mass spectrometer, column, acquisition software, service plan, region and discount. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the compatibility, service and approval rules and returns a verdict, every reason and the system figures it computed.
This validator models quotes for LC/MS analytical instrument systems built from an LC module, a mass spectrometer, a column and acquisition software — not just the scenarios shown below.
Any LC/MS system quote touching these choices is in scope — not only the scenarios pictured here. Not covered: prices (Agilent publishes no list prices for these systems, so this validator produces no price build-up or line-item quote), GC and other instrument families, consumables, and any vendor CPQ platform. Assumptions: software support per instrument, minimum service levels, regional discount limits, regional plan availability and export-review flags are invented illustrative values.
6 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A column with sub-2 micron particles on an LC that cannot run UHPLC pressures | Only with care Doable as a product rule linking column to LC, but the pressure limits and particle sizes must be copied onto every column and LC record and kept in step. | Pressure limits and the UHPLC flag sit on the product records and are compared with the method on every call. |
| Acquisition software that does not control the chosen mass spectrometer | Only with care One product rule per software and instrument pair. It works, but every new instrument or software release adds rules to maintain. | Support comes from the instrument record, so a new instrument is a new row, not a new rule. |
| Minimum service plan by instrument, and plans not offered in a region | Only with workarounds Service attach is usually a separate bundle or line. Checking it against the instrument and the region needs custom validation or a manual review step. | The minimum service level and regional availability are checked together with the rest of the system on every call. |
| A quote that states a system pressure limit different from what the LC and column allow | Only with workarounds A validation rule can compare a stated figure only if the stated figure is a field on the quote, and the lower of two product limits is computed first. | The stated figure travels with the quote and is compared with the computed limit on every call. |
| Regional discount authority plus an export-compliance review, all reported together | Only with care Approval rules are easy one at a time. Several reasons at once usually mean several approval rules firing separately, each with its own message. | Every approval reason is listed together with the block reasons, in order of severity. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | a method pressure of 900 bar is above the 600 bar limit of the InfinityLab 1260 Infinity II LC. |
| 2 | the 6546 LC/Q-TOF must be paired with a UHPLC-class LC; the InfinityLab 1260 Infinity II LC is not one. |
| 3 | the ZORBAX RRHD Eclipse Plus C18 1.8 micron uses sub-2 micron particles and needs a UHPLC-class pump; the InfinityLab 1260 Infinity II LC is not one. |
| 4 | the method mobile phase pH is outside the pH 2.0 to 8.0 operating range of the InfinityLab Poroshell 120 EC-C18 2.7 micron. |
| 5 | the selected acquisition software does not control the Ultivo LC/TQ (triple quadrupole). |
| 6 | the 6470C LC/TQ (triple quadrupole) requires at least service level 2 (0 none, 1 warranty, 2 bronze, 3 silver, 4 gold); the quote has Extended Warranty. |
| 7 | CrossLab Gold is not offered in India. |
| 8 | a service term of 6 years is above the 5 year maximum. |
| 9 | a discount of 21 percent is above the 20 percent limit that anyone can approve in Japan. |
| 10 | the quote states a system pressure limit of 1200 bar, but this LC and column pair is limited to 600 bar. |
| 11 | a discount of 18 percent is above the 10 percent a sales rep can give in China; it needs sales management approval. |
| 12 | the 6546 LC/Q-TOF shipping to China needs an export-compliance review before the quote is released. |
| 13 | the system has no service contract attached; confirm the customer has declined service. |
| 14 | a method pressure of 540 bar leaves under 10 percent headroom below the 600 bar system limit; confirm the method with the customer. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a system for a customer in United States: the InfinityLab 1260 Infinity II LC, the 6470C LC/TQ (triple quadrupole), the ZORBAX RRHD Eclipse Plus C18 1.8 micron column, controlled by MassHunter software. The method runs at 900 bar and pH 3.0. Service: CrossLab Silver for 3 years. Requested discount: 0 percent. The quote states a system pressure limit of 1200 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a system for a customer in United States: the InfinityLab 1290 Infinity II LC, the 6470C LC/TQ (triple quadrupole), the ZORBAX RRHD Eclipse Plus C18 1.8 micron column, controlled by MassHunter software. The method runs at 900 bar and pH 3.0. Service: CrossLab Silver for 3 years. Requested discount: 0 percent. The quote states a system pressure limit of 1200 bar. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a system for a customer in United States: the InfinityLab 1290 Infinity II LC, the 6495D LC/TQ (triple quadrupole), the ZORBAX RRHD Eclipse Plus C18 1.8 micron column, controlled by OpenLab CDS software. The method runs at 800 bar and pH 3.0. Service: CrossLab Bronze for 3 years. Requested discount: 0 percent. The quote states a system pressure limit of 1200 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a system for a customer in United States: the InfinityLab 1290 Infinity II LC, the 6495D LC/TQ (triple quadrupole), the ZORBAX RRHD Eclipse Plus C18 1.8 micron column, controlled by MassHunter software. The method runs at 800 bar and pH 3.0. Service: CrossLab Silver for 3 years. Requested discount: 0 percent. The quote states a system pressure limit of 1200 bar. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a system for a customer in China: the InfinityLab 1290 Infinity II LC, the 6546 LC/Q-TOF, the InfinityLab Poroshell HPH-C18 2.7 micron column, controlled by MassHunter software. The method runs at 450 bar and pH 11.0. Service: CrossLab Gold for 3 years. Requested discount: 25 percent. The quote states a system pressure limit of 600 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a system for a customer in China: the InfinityLab 1290 Infinity II LC, the 6546 LC/Q-TOF, the InfinityLab Poroshell HPH-C18 2.7 micron column, controlled by MassHunter software. The method runs at 450 bar and pH 11.0. Service: CrossLab Silver for 3 years. Requested discount: 18 percent. The quote states a system pressure limit of 600 bar. It is ready to send.
Verdict: Needs approval.
The text of the narrated walkthrough, step by step.