Predictika · Liquid chromatography system quotes
An AI sales agent drafts a quote for a liquid chromatography (LC) system: the pump, sampler, thermostat, detector, column and data software, the service plan, the destination and the discount. Before the quote goes out, the agent sends it to Predictika, which checks it against a declarative model of the module, column and pressure limits, the compliance and service rules and the discount authority, compares the net total the agent states with the one it computes, and reports every problem it finds in one pass.
This validator models 1290 and 1260 Infinity II style LC system quotes, including LC/MS, regulated-lab software and service. It handles any quote made of these modules, columns and terms, not just the scenarios shown below.
Any LC system quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: GC, ICP-MS and other instrument families, consumables other than the quoted column lines, method validation, real list prices and contract pricing, or module generations beyond the catalog.
6 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Expected pressure from the method against the weakest module or column | Only with workarounds Needs a formula from flow, column geometry and particle size, a minimum across four components and a comparison with a review band; this is calculation, not selection, and CPQ rules handle it awkwardly. | Computed from the choices and compared with every limit on every call. |
| Detector flow cell against column diameter, and mass spectrometer flow and buffer limits | Only with care Compatibility rules across three fields; they work, but each new detector adds rows. | Limits are catalog data; the checks follow from the choices. |
| Compliance software, instrument count and qualification for a regulated lab | Only with care Dependency rules keyed on a customer flag; reliable only if the flag is always set. | Checked together with everything else. |
| The total the agent states | Only with workarounds Comparing a stated total with a computed one means a separate rule per quote layout, and price rules rarely run on stated figures. | The stated net total is a field in the request and is checked against the computed total. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | Expected pressure of 1,087 bar is within 10 percent of the 1,200 bar limit; applications support must review the method robustness. |
| 2 | A mass spectrometer to China needs an export compliance review before the order is accepted. |
| 3 | 10 percent discount is above the 5 percent a rep can give; approvable up to 15 percent for a Direct order. |
| 4 | Net order value of $495,168 is above $250,000 and needs a sales director review. |
| 5 | Expected system pressure of 677 bar (column 597 plus overhead) exceeds the 600 bar limit of the weakest module or column. |
| 6 | Flow of 600 (mL/min x 100) exceeds the 500 that 1290 Infinity II High-Speed Pump (binary) can deliver. |
| 7 | The method uses 4 solvents but 1290 Infinity II High-Speed Pump (binary) supports 2. |
| 8 | Injection of 50 uL exceeds the 20 uL maximum of 1290 Infinity II Vialsampler. |
| 9 | Column temperature of 90 C exceeds the 80 C maximum of 1260 Infinity II Multicolumn Thermostat. |
| 10 | The mass spectrometer accepts at most 1 mL/min; a flow split must be added for this flow. |
| 11 | A mass spectrometer needs a volatile mobile phase; nonvolatile buffer would contaminate the source. |
| 12 | The 1260 Infinity II Diode Array Detector (13 uL cell) flow cell volume would broaden peaks on a narrow bore column. |
| 13 | A regulated lab needs electronic records compliance and OpenLab CDS Workstation Lite does not provide it. |
| 14 | OpenLab CDS Workstation Lite supports up to 2 instruments and 3 systems are quoted. |
| 15 | A regulated lab needs installation and operational qualification and it is not included. |
| 16 | Premium service is not available in India. |
| 17 | Expected lead time is 11 weeks to Brazil but the customer needs it in 8. |
| 18 | 20 percent discount exceeds the 15 percent limit for a Direct order. |
| 19 | The quoted net total of $172,632.48 does not match the $187,644 the validator computed. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. This is for a regulated quality control lab in India that needs the system within 12 weeks. A 1290 Infinity II system with the High-Speed Pump, Multisampler, Multicolumn Thermostat and Diode Array Detector, the ZORBAX RRHD 2.1 x 100 mm 1.8 um column, OpenLab compliance software and 3 years of premium service, shipped to India. Net total $168,840. It is ready to send.
Verdict: Blocked.
The agent's request. This is for a regulated quality control lab in India that needs the system within 12 weeks. A 1290 Infinity II system with the High-Speed Pump, Multisampler, Multicolumn Thermostat and Diode Array Detector, the ZORBAX RRHD 2.1 x 100 mm 1.8 um column, OpenLab compliance software, IQ/OQ qualification and 3 years of standard service, shipped to India. Net total $158,940. It is ready to send.
Verdict: Allowed.
The agent's request. This is for a contract lab in the United States setting up a routine method on a 2.1 mm column with fast run times. A 1290 Infinity II system with the High-Speed Pump, Multisampler, Multicolumn Thermostat and Diode Array Detector, a Poroshell 120 2.1 x 100 mm 2.7 um column run at 1.2 mL/min, OpenLab compliance software and 3 years of standard service. Direct order for the United States. Net total $154,460. It is ready to send.
Verdict: Blocked.
The agent's request. This is for a contract lab in the United States setting up a routine method on a 2.1 mm column with fast run times. A 1290 Infinity II system with the High-Speed Pump, Multisampler, Multicolumn Thermostat and Diode Array Detector, a Poroshell 120 2.1 x 100 mm 2.7 um column run at 0.6 mL/min, OpenLab compliance software and 3 years of standard service. Direct order for the United States. Net total $154,460. It is ready to send.
Verdict: Allowed.
The agent's request. This is for a regulated contract lab in the United States adding two routine HPLC systems. Two 1260 Infinity II systems, each with the Binary Pump, Vialsampler, Multicolumn Thermostat and Diode Array Detector, three Poroshell 120 4.6 x 150 mm columns per system, OpenLab compliance software, IQ/OQ qualification and 3 years of standard service. Direct order for the United States. Net total $172,632.48. It is ready to send.
Verdict: Blocked.
The agent's request. This is for a regulated contract lab in the United States adding two routine HPLC systems. Two 1260 Infinity II systems, each with the Binary Pump, Vialsampler, Multicolumn Thermostat and Diode Array Detector, three Poroshell 120 4.6 x 150 mm columns per system, OpenLab compliance software, IQ/OQ qualification and 3 years of standard service. Direct order for the United States. Net total $187,644. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.