Predictika · Industrial connector orders: miniature cylindrical connectors
An AI sales agent prepares an order for miniature cylindrical bayonet connectors with solder contacts: the series and shell style, service class, shell size, insert arrangement, pin or socket contacts, insert rotation, finish, strain relief, the operating voltage and the total contact count. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published catalog and returns a verdict, every reason and the figures it computed.
This validator models part numbers for one connector family, the Amphenol PT, SP and MS/PT (MIL-DTL-26482 Series 1) solder-contact connectors, using the Amphenol Industrial catalog 12-070-20, not just the scenarios shown below.
Any order for these connectors that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none are published, so this validator produces no price build-up or line-item quote), the hermetic, crimp (SE), printed circuit board and coax styles, the PG and J service classes, the PTG grounding plug, arrangements with letter codes or high-voltage ratings, other Amphenol connector families, stock and lead times.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Insert arrangements that differ by series and size | Only with workarounds Each of the PT, SP and MS/PT series lists a different set of insert arrangements per shell size, so the catalog table becomes a grid of combinations that has to be loaded and kept in step by hand. | Series, shell size and arrangement are in one request; the combination is checked against the offered set for that series on every call. |
| Rotations and contact types that depend on the arrangement | Only with workarounds Which insert rotations are offered, and whether an arrangement takes pins or sockets only, depend on the exact arrangement, so each needs its own lookup rule. | The rotation and the contact type are checked against the arrangement actually chosen, in the same call. |
| Styles, classes and strain relief that depend on the series | Only with care The styles, service classes and strain relief options differ by series, and the size 24 strain relief exception adds another dependency. | Series, style, class, strain relief and size are checked together, so a combination that is offered in one series and not in another is caught. |
| A stated contact count that disagrees with the order | Only with workarounds The count the agent states is a free-entry figure, so it takes an extra rule that multiplies the quantity by the contacts of the chosen arrangement and compares the total. | The stated count is part of the request and is compared with the computed total on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | Shell style cable connecting receptacle (01) is not offered in the SP series; the cable connecting receptacle (01) is not made in SP, and the 90 degree plug (08) and thru-bulkhead receptacle (TB) are not made in MS/PT. |
| 2 | Shell style 90 degree plug (08) is not offered in the MS/PT series; the cable connecting receptacle (01) is not made in SP, and the 90 degree plug (08) and thru-bulkhead receptacle (TB) are not made in MS/PT. |
| 3 | Shell style thru-bulkhead receptacle (TB) is not offered in the MS/PT series; the cable connecting receptacle (01) is not made in SP, and the 90 degree plug (08) and thru-bulkhead receptacle (TB) are not made in MS/PT. |
| 4 | Shell size 6 is not offered here; sizes are 6, 8, 10, 12, 14, 16, 18, 20, 22 and 24, except that MS/PT and the 90 degree plug start at size 8. |
| 5 | Service class C is not offered for shell style straight plug (06) in the PT series. |
| 6 | Service class C is not offered for shell style cable connecting receptacle (01) in the PT series. |
| 7 | Service class P is not offered for shell style jam nut receptacle (07) in the SP series. |
| 8 | Service class A is not offered for shell style straight plug (06) in the MS/PT series. |
| 9 | Service class F is not offered for shell style straight plug (06) in the PT series. |
| 10 | Service class E is not offered for shell style thru-bulkhead receptacle (TB) in the PT series. |
| 11 | Shell size 7 is not offered here; sizes are 6, 8, 10, 12, 14, 16, 18, 20, 22 and 24, except that MS/PT and the 90 degree plug start at size 8. |
| 12 | Insert arrangement 6-1 is not offered in the MS/PT series. |
| 13 | Shell size 26 is not offered here; sizes are 6, 8, 10, 12, 14, 16, 18, 20, 22 and 24, except that MS/PT and the 90 degree plug start at size 8. |
| 14 | Insert arrangement 20-99 is not offered in the PT series. |
| 15 | Insert arrangement 12-14 is not offered in the MS/PT series. |
| 16 | Insert arrangement 18-8 is not offered in the SP series. |
| 17 | Insert arrangement 14-4 is offered with socket contacts only; pin contacts were requested. |
| 18 | Contact configuration PS (pin and socket) is not valid for shell style straight plug (06); the thru-bulkhead receptacle is ordered with PS (pin and socket ends) and every other style with P (pins) or S (sockets). |
| 19 | Contact configuration Pin is not valid for shell style thru-bulkhead receptacle (TB); the thru-bulkhead receptacle is ordered with PS (pin and socket ends) and every other style with P (pins) or S (sockets). |
| 20 | Insert rotation Z is not offered for insert arrangement 20-41. |
| 21 | Insert rotation X is not offered for insert arrangement 12-3. |
| 22 | Insert rotation W is not offered for insert arrangement 12-14. |
| 23 | A strain relief clamp (SR) is not offered for the MS/PT series, shell style straight plug (06), class E. |
| 24 | A strain relief clamp (SR) is not offered for the PT series, shell style box mounting receptacle (02), class E. |
| 25 | The SP jam nut receptacle in class A is listed only with the strain relief clamp (SR); none was requested. |
| 26 | Size 24 strain relief is available in the PT series only; SP was requested. |
| 27 | Finish 23 is not offered for the MS/PT series; MS/PT is standard olive drab cadmium and the PT and SP finishes are 003, 005, 023, 025, 072, 424, 470 and 725. |
| 28 | Finish 999 is not offered for the PT series; MS/PT is standard olive drab cadmium and the PT and SP finishes are 003, 005, 023, 025, 072, 424, 470 and 725. |
| 29 | Finish 424 is a strain relief finish and needs the strain relief clamp (SR); none was requested. |
| 30 | An operating voltage of 700 V AC is above the 600 V AC recommended at sea level for the service rating of this insert arrangement. |
| 31 | An operating voltage of 1100 V AC is above the 1000 V AC recommended at sea level for the service rating of this insert arrangement. |
| 32 | The quantity is 0; at least one connector is needed. |
| 33 | The order states 450 contacts in total; the connectors ordered carry 410. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 25 Amphenol SP series cable connecting receptacle (01) connectors, service class E, shell size 20, insert arrangement 20-41 with socket contacts. Operating voltage is 500 V AC. The order is 1,025 contacts in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 25 Amphenol PT series cable connecting receptacle (01) connectors, service class E, shell size 20, insert arrangement 20-41 with socket contacts. Operating voltage is 500 V AC. The order is 1,025 contacts in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 40 Amphenol PT series straight plug (06) connectors, service class E, shell size 12, insert arrangement 12-3 with pin contacts, insert rotation X. Operating voltage is 1,100 V AC. The order is 120 contacts in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 40 Amphenol PT series straight plug (06) connectors, service class E, shell size 12, insert arrangement 12-3 with pin contacts, insert rotation Y. Operating voltage is 1,100 V AC. The order is 120 contacts in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 40 Amphenol PT series straight plug (06) connectors, service class E, shell size 12, insert arrangement 12-3 with pin contacts, insert rotation Y. Operating voltage is 1,000 V AC. The order is 120 contacts in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 12 Amphenol SP series straight plug (06) connectors, service class E, shell size 24, insert arrangement 24-61 with pin contacts, with the strain relief clamp, finish 424. Operating voltage is 500 V AC. The order is 732 contacts in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 12 Amphenol PT series straight plug (06) connectors, service class E, shell size 24, insert arrangement 24-61 with pin contacts, with the strain relief clamp, finish 424. Operating voltage is 500 V AC. The order is 732 contacts in total. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.