An AI sales agent prepares a suspension grid order for a commercial ceiling: Prelude XL 15/16 inch exposed tee main beams, cross tees and wall or shadow molding, in a finish, with piece counts, the ceiling load, any Fire Guard or seismic requirement, and the total cartons it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the item, finish, load and carton figures in Armstrong's public data sheet and returns a verdict, every reason and the cartons it computed.
This validator models one Prelude XL grid order at a time, based on the items and tables in the public Armstrong Prelude XL and Prelude XL High Recycled Content data sheet, not just the scenarios shown below.
Any Prelude XL grid order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the data sheet publishes none, so this page shows no price build-up), other Armstrong suspension systems and ceiling panels, made-to-order sizes and rout spacing, hanger wire and accessories other than BERC2, and engineering sign-off of a real ceiling.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Items that exist only in some finishes | Only with workarounds Each item has its own list of finishes, and moldings follow a different list. A rules-based CPQ needs an item-by-finish table or a rule per footnote, and each data sheet update means editing them. | Item and finish arrive in one request and are checked against the published footnotes on every call. |
| Fire Guard and seismic options that depend on other items | Only with care Whether an item has a Fire Guard version, and whether a molding needs clips in seismic design category D, E or F, depends on the main beam, cross tee and molding chosen elsewhere in the order. | The main beam, cross tee, molding, finish, clips and the two options are compared together, in any order. |
| Load rating against ceiling weight | Only with care The rating depends on the main beam and the hanger spacing, and the load depends on weight and beam spacing, so the rule needs a lookup and a calculation at once. | The rating lookup and the load are computed on every call and compared, including at the exact limit. |
| Cartons rounded up per line | Only with care Each line rounds up to whole cartons at a different pieces-per-carton figure, and the stated total has to be recomputed and compared. | Every line is rounded and totaled on every call, and the stated total is a field compared with the computed one. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The order needs at least 1 main beam and 1 cross tee piece, and no negative counts; it has 0 main beams and 300 cross tees. |
| 2 | The data sheet publishes main beam load ratings only for 4 foot and 5 foot hanger wire spacing; the order uses 6 feet. |
| 3 | The ceiling load on a main beam is 16.76 pounds per linear foot; the selected main beam is rated 16.73 pounds per linear foot at that hanger spacing (L/360 test load). |
| 4 | The ceiling load on a main beam is 13.52 pounds per linear foot; the selected main beam is rated 13.50 pounds per linear foot at that hanger spacing (L/360 test load). |
| 5 | The ceiling load on a main beam is 8.75 pounds per linear foot; the selected main beam is rated 8.73 pounds per linear foot at that hanger spacing (L/360 test load). |
| 6 | A fixture of 57 pounds is over 56 pounds; the data sheet says fixtures weighing more than 56 pounds should be independently supported. |
| 7 | The selected main beam is listed only in White, Blizzard White and Charcoal Black finishes; the order asks for another finish. |
| 8 | The selected cross tee is listed only in White, Blizzard White and Charcoal Black finishes; the order asks for another finish. |
| 9 | The selected molding is not offered in the requested finish; the data sheet lists it only in White, Blizzard White and Charcoal Black, or not in Silver Grey, Gun Metal Grey and Silver Satin. |
| 10 | The data sheet lists the Fire Guard items 8301 and XL8341 without a finish note; a person should confirm the finish with Armstrong TechLine. |
| 11 | The Fire Guard items 8300, XL8340 and XL8323 are listed in Black and White only; the order asks for another finish. |
| 12 | Fire Guard items are listed only for the 12 foot main beams 7301 and 7300 and the 4 foot cross tees XL7341 and XL7340 and the 2 foot cross tee XL7328; the selected main beam or cross tee has no Fire Guard item. |
| 13 | The 7/8 inch wall molding in seismic design category D, E or F needs BERC2 beam end retaining clips or a 2 inch wall molding; the order has 0 clips. |
| 14 | The selected intermediate-duty main beam has no seismic category listing in the data sheet; use a heavy-duty main beam for seismic design category D, E or F. |
| 15 | The 7877, 7878 and 7897 shadow moldings are suitable for seismic design category D, E or F only with the Seismic Rx suspension system and the BERC2 clip; the order has 0 clips. |
| 16 | The 7875 shadow molding is not among the shadow moldings the data sheet lists as suitable for seismic design category D, E or F; a person should confirm it. |
| 17 | A custom color is made to order and the data sheet says lead time increases and sustainability criteria must be evaluated; a person should confirm it. |
| 18 | The order states 11 cartons in total; the pieces per carton in the data sheet give 12 cartons. |
| 19 | The order states 13 cartons in total; the pieces per carton in the data sheet give 12 cartons. |
| 20 | The order states 1 carton in total; the pieces per carton in the data sheet give 12 cartons. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please prepare a Prelude XL grid order of 7301 heavy-duty 12 foot main beams (160 pieces), XL7341 4 foot cross tees (600 pieces) and 7808 hemmed angle molding, 2 inch (120 pieces) in white, with no BERC2 clips, for a ceiling with a load of 4.50 pounds per square foot on main beams 4 feet apart and hanger wires 4 feet apart. Fire Guard is not required and seismic design category D, E or F is not required. The heaviest light fixture is 62 pounds. The order states 27 cartons in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a Prelude XL grid order of 7301 heavy-duty 12 foot main beams (160 pieces), XL7341 4 foot cross tees (600 pieces) and 7808 hemmed angle molding, 2 inch (120 pieces) in white, with no BERC2 clips, for a ceiling with a load of 4.00 pounds per square foot on main beams 4 feet apart and hanger wires 4 feet apart. Fire Guard is not required and seismic design category D, E or F is not required. The heaviest light fixture is 50 pounds. The order states 30 cartons in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare a Prelude XL grid order of 7300 intermediate-duty 12 foot main beams (240 pieces), XL7340 4 foot cross tees (960 pieces) and 7808 hemmed angle molding, 2 inch (150 pieces) in light grey, with no BERC2 clips, for a ceiling with a load of 1.10 pounds per square foot on main beams 4 feet apart and hanger wires 4 feet apart. Fire Guard is required and seismic design category D, E or F is not required. The heaviest light fixture is 0 pounds. The order states 43 cartons in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a Prelude XL grid order of 7300 intermediate-duty 12 foot main beams (240 pieces), XL7340 4 foot cross tees (960 pieces) and 7808 hemmed angle molding, 2 inch (150 pieces) in white, with no BERC2 clips, for a ceiling with a load of 1.10 pounds per square foot on main beams 4 feet apart and hanger wires 4 feet apart. Fire Guard is required and seismic design category D, E or F is not required. The heaviest light fixture is 0 pounds. The order states 43 cartons in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare a Prelude XL grid order of 7300 intermediate-duty 12 foot main beams (400 pieces), XL7342 4 foot (1-1/2 inch) cross tees (1,200 pieces) and 7800 hemmed angle molding, 7/8 inch (300 pieces) in white, with no BERC2 clips, for a ceiling with a load of 0.95 pounds per square foot on main beams 4 feet apart and hanger wires 4 feet apart. Fire Guard is not required and seismic design category D, E or F is required. The heaviest light fixture is 0 pounds. The order states 50 cartons in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a Prelude XL grid order of 7301 heavy-duty 12 foot main beams (400 pieces), XL7342 4 foot (1-1/2 inch) cross tees (1,200 pieces) and 7875 shadow molding (300 pieces) in white, with 400 clips, for a ceiling with a load of 0.95 pounds per square foot on main beams 4 feet apart and hanger wires 4 feet apart. Fire Guard is not required and seismic design category D, E or F is required. The heaviest light fixture is 0 pounds. The order states 52 cartons in total. It is ready to send.
Verdict: Needs approval.
The agent's request. Please prepare a Prelude XL grid order of 7301 heavy-duty 12 foot main beams (400 pieces), XL7342 4 foot (1-1/2 inch) cross tees (1,200 pieces) and 7877 shadow molding (300 pieces) in white, with 400 clips, for a ceiling with a load of 0.95 pounds per square foot on main beams 4 feet apart and hanger wires 4 feet apart. Fire Guard is not required and seismic design category D, E or F is required. The heaviest light fixture is 0 pounds. The order states 52 cartons in total. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.