Predictika · Pressure instrumentation
An AI sales agent prepares an order for an Ashcroft 1009 stainless steel case pressure gauge for a process line: the system material, the pressure range, the process connection, dry or liquid-filled case, the operating temperatures, the options, and the maximum pressure and temperature it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the public Ashcroft data sheet and returns a verdict, every reason and the figures it computed.
This validator models an order for an Ashcroft model 1009 gauge (304 stainless steel case, open front) in the bronze, 316L stainless steel or Monel system, with a psi range, based on the public Ashcroft 1009 data sheet (Rev. C, June 2020), not just the scenarios shown below.
Any 1009 gauge order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the data sheet has none, so this page shows no price build-up), other Ashcroft gauges, transducers, transmitters and diaphragm seals, bar, kPa, MPa and kg/cm2 ranges, dial size and dimensions, window material, and the options that the data sheet describes without limits (calibration chart, oxygen service, safety glass, maximum pointer, tag, stainless steel movement, 0.5% accuracy), which are accepted without rules.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Maximum pressure that depends on the system material | Only with workarounds The bronze, stainless steel and Monel systems have different maximum pressures, and two ranges exist for one system only. A rules-based CPQ needs a compatibility table or a rule per range and system, and a data sheet revision means editing them. | The system, the range and the connection arrive in one request and are checked against each other on every call. |
| Temperature limits that depend on the case fill | Only with care Dry, PLUS!, glycerin, silicone and Halocarbon versions each have their own ambient and process limits. It needs a lookup by version, and a second check against the temperatures the order states. | The limits are computed from the version on every call and compared with both the operating temperatures and the maximum the order states. |
| Options that depend on the case fill | Only with workarounds The red set hand is not available with liquid fill, and silicone and Halocarbon fill exist only on a liquid-filled case. Each is a separate exclusion rule, usually spread across option groups. | Every combination is checked together, and each failure is named. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | A range of 1,500 psi is above the 1,000 psi maximum for this system. |
| 2 | A range of 30,000 psi is above the 20,000 psi maximum for this system. |
| 3 | The 30,000 psi range is for Monel systems only. |
| 4 | The 20,000 psi range is for stainless steel systems only. |
| 5 | A range of 20,000 psi is above the 1,000 psi maximum for this system. |
| 6 | Ranges over 20,000 psi need the 9/16-18 UNF-2B high-pressure connection; the 1/4 NPT and 1/2 NPT connections are limited to 20,000 psi. |
| 7 | The catalog lists no standard compound range with a full scale of 200 psi. |
| 8 | The catalog lists no standard positive-pressure range with a full scale of 250 psi. |
| 9 | The catalog lists no standard positive-pressure range with a full scale of 500 psi. |
| 10 | The process temperature of 251 degrees F is above the 250 degrees F maximum for this version. |
| 11 | The process temperature of -21 degrees F is below the -20 degrees F minimum for this version. |
| 12 | The ambient temperature of 201 degrees F is above the 200 degrees F maximum for this version. |
| 13 | The ambient temperature of 19 degrees F is below the 20 degrees F minimum for this version. |
| 14 | The process temperature of 201 degrees F is above the 200 degrees F maximum for this version. |
| 15 | The ambient temperature of 151 degrees F is above the 150 degrees F maximum for this version. |
| 16 | Silicone and Halocarbon case fill apply to a liquid-filled case; this gauge is dry. |
| 17 | Only one case fill can be chosen; silicone fill and Halocarbon fill were both selected. |
| 18 | The adjustable red set hand is not available with a liquid-filled case. |
| 19 | 2 mounting options (front flange, back flange, U-clamp) were selected; the data sheet lists each as a separate option and does not say they can be combined, so a person should confirm. |
| 20 | The gauge is dry and not hermetically sealed, and its case is not sealed; the catalog recommends it for weather-protected environments only, so a person should confirm outdoor use. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a 1009 pressure gauge in the 316L stainless steel system with a liquid-filled (glycerin) case, a 1/4 NPT male connection (lower location) and a range of 15,000 psi. The process runs at 220 degrees F and the ambient temperature is 70 degrees F. The quote states a maximum system pressure of 20,000 psi. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a 1009 pressure gauge in the 316L stainless steel system with a dry case, a 9/16-18 UNF-2B high-pressure fitting connection (lower location) and a range of 15,000 psi. The process runs at 220 degrees F and the ambient temperature is 70 degrees F. The quote states a maximum system pressure of 20,000 psi and a maximum process temperature of 250 degrees F. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a 1009 pressure gauge in the bronze system (phosphor bronze tube, brass connection) with a dry case, a 1/4 NPT male connection (lower location) and a range of 1,500 psi. The process runs at 70 degrees F and the ambient temperature is 70 degrees F. The gauge will be installed outdoors. The quote states a maximum process temperature of 250 degrees F. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a 1009 pressure gauge in the bronze system (phosphor bronze tube, brass connection) with a dry case, a 1/4 NPT male connection (lower location) and a range of 1,000 psi. The process runs at 70 degrees F and the ambient temperature is 70 degrees F. The gauge will be installed outdoors. The quote states a maximum system pressure of 1,000 psi and a maximum process temperature of 250 degrees F. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a 1009 pressure gauge in the bronze system (phosphor bronze tube, brass connection) with a dry case, a 1/4 NPT male connection (lower location) and a range of 1,000 psi. The process runs at 70 degrees F and the ambient temperature is 70 degrees F. Add hermetic sealing. The gauge will be installed outdoors. The quote states a maximum system pressure of 1,000 psi and a maximum process temperature of 250 degrees F. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a 1009 pressure gauge in the 316L stainless steel system with a silicone-filled case, a 1/4 NPT male connection (lower location) and a range of 100 psi. The process runs at -30 degrees F and the ambient temperature is -30 degrees F. Add an adjustable red set hand. The quote states a maximum system pressure of 20,000 psi and a maximum process temperature of 200 degrees F. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a 1009 pressure gauge in the 316L stainless steel system with a silicone-filled case, a 1/4 NPT male connection (lower location) and a range of 100 psi. The process runs at -30 degrees F and the ambient temperature is -30 degrees F. The quote states a maximum system pressure of 20,000 psi and a maximum process temperature of 200 degrees F. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.