An AI sales agent prepares an order for compact peristaltic pump systems: the pump system, how many channels each needs, the tubing size, the speed it runs at, the flow the lab needs on each channel, and the pressure, vacuum and room it will work in. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures the manufacturer publishes and returns a verdict, every reason and the figures it computed.
This validator models orders for the Masterflex L/S Miniflex pump systems listed in the public L/S OEM Miniflex Pump Heads technical data sheet, not just the scenarios shown below.
Any order for these Miniflex pump systems that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the data sheet lists none, so this page shows no price build-up), stand-alone pump heads, other Masterflex pumps and tubing families, tubing material and formulation (the data sheet says actual performance varies with formulation), fittings, and real-world flow, which depends on tubing condition and the fluid.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Flow on each channel from tubing size and speed, against what the lab needs | Only with care Each tubing size pumps a different volume per turn, and the speed range depends on which system was chosen. A rules-based CPQ can hold this in lookup tables and a formula, but they are separate pieces to keep in step with the data sheet. | Size, speed, channels and quantity are in one request and the flow is computed and compared on every call. |
| Tubing that only some heads accept (L/S 25 on single-channel systems only) | Only with care A product rule between tubing and system works, but it is one more rule to keep for every system family and size. | Every system and tubing choice is checked together, in any order. |
| A control signal tied to the exact system SKU (4 to 20 mA or 0 to 10 V) | Only with workarounds The right signal depends on a suffix of the system part number on another line, so it needs a cross-line rule that has to be edited whenever a new system is added. | The system and the signal are in one request and matched on every call. |
| Pressure ratings that differ by tubing size, and one the data sheet prints two ways | Only with workarounds A hard stop is easy, but a rule that stops for one size, asks a person for another, and stops everywhere above 40 psi needs several rules that interact. | Blocks and approvals are separate findings, so the quote stops or goes to a person depending on what is found. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote has 0 pump systems; at least 1 is needed. |
| 2 | L/S size 15 tubing is not accepted by the Miniflex pump head; it takes L/S 13, 14, 16 and 25. |
| 3 | The data sheet says to use only Masterflex L/S pump tubing; the quote uses other tubing. |
| 4 | The customer needs 2 channels on each pump system; the selected system has 1 channel. |
| 5 | L/S 25 tubing fits the single-channel head only; the dual-channel head takes L/S 13, 14 and 16. |
| 6 | The quote sets 250 revolutions per minute; the selected system runs from 35 to 200 revolutions per minute. |
| 7 | The quote sets 30 revolutions per minute; the selected system runs from 35 to 200 revolutions per minute. |
| 8 | The quote sets 310 revolutions per minute; the selected system runs from 0.1 to 300 revolutions per minute. |
| 9 | The customer needs 75,001 microliters a minute on each channel; the quoted tubing at the quoted speed gives 75000. |
| 10 | The application runs at 41 psi; the data sheet lists a maximum of 40 psi. |
| 11 | The data sheet gives the L/S 25 pressure rating as 2.4 bar (20 psi), and the application runs at 25 psi; a person should confirm the rating. |
| 12 | The application needs 27 inches of mercury of vacuum; the data sheet lists a maximum of 26. |
| 13 | The room temperature of 41 degrees Celsius is outside the 0 to 40 degree operating range. |
| 14 | The room temperature of -2 degrees Celsius is outside the 0 to 40 degree operating range. |
| 15 | This panel-mount system is controlled by one specific signal (4 to 20 mA for -10, 0 to 10 V for -12); the quote selects a different one. |
| 16 | The data sheet lists an analog control signal only for the OEM panel-mount systems; a person should confirm the control for this system. |
| 17 | The quote states 140,000 microliters a minute of total flow; the quoted systems give 150000. |
| 18 | The quote states 160,000 microliters a minute of total flow; the quoted systems give 150000. |
| 19 | The customer needs 3 channels on each pump system; the selected system has 2 channels. |
| 20 | The quote sets 350 revolutions per minute; the selected system runs from 0.1 to 300 revolutions per minute. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 6 MFLX07525-40 L/S digital Miniflex pump systems, each with 2 channels, fitted with L/S 25 tubing and run at 250 revolutions per minute, for a customer that needs 250,000 microliters a minute on each channel at 18 psi in a room at 22 degrees Celsius. The quote states 3,300,000 microliters a minute of total flow. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 12 MFLX07525-20 L/S digital Miniflex pump systems, each with 1 channel, fitted with L/S 25 tubing and run at 230 revolutions per minute, for a customer that needs 250,000 microliters a minute on each channel at 18 psi in a room at 22 degrees Celsius. The quote states 3,036,000 microliters a minute of total flow. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 5 MFLX77240-20 analog compact pump systems, each with 1 channel, fitted with L/S 16 tubing and run at 250 revolutions per minute, for a customer that needs 120,000 microliters a minute on each channel at 20 psi in a room at 24 degrees Celsius. The quote states 625,000 microliters a minute of total flow. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 5 MFLX07525-20 L/S digital Miniflex pump systems, each with 1 channel, fitted with L/S 16 tubing and run at 250 revolutions per minute, for a customer that needs 120,000 microliters a minute on each channel at 20 psi in a room at 24 degrees Celsius. The quote states 625,000 microliters a minute of total flow. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 8 MFLX77222-12 OEM panel-mount pump systems, each with 1 channel, fitted with L/S 16 tubing and run at 150 revolutions per minute, for a customer that needs 90,000 microliters a minute on each channel at 25 psi in a room at 26 degrees Celsius. The pumps are driven by a 4 to 20 mA control signal. The quote states 600,000 microliters a minute of total flow. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 8 MFLX77222-12 OEM panel-mount pump systems, each with 1 channel, fitted with L/S 25 tubing and run at 150 revolutions per minute, for a customer that needs 90,000 microliters a minute on each channel at 25 psi in a room at 26 degrees Celsius. The pumps are driven by a 0 to 10 V control signal. The quote states 1,320,000 microliters a minute of total flow. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 8 MFLX77222-12 OEM panel-mount pump systems, each with 1 channel, fitted with L/S 16 tubing and run at 200 revolutions per minute, for a customer that needs 90,000 microliters a minute on each channel at 25 psi in a room at 26 degrees Celsius. The pumps are driven by a 0 to 10 V control signal. The quote states 800,000 microliters a minute of total flow. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.