Predictika · Industrial compressed air orders
An AI sales agent prepares an order for a BOGE S-4 series oil-lubricated screw compressor: a model, an operating pressure, whether it has the integrated dryer, the sound insulation, the plant's air demand, the piping and the room it has to fit in. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the S-4 series data sheet and returns a verdict, every reason and the figures it computed.
This validator models orders for this one series, not just the scenarios shown below.
Any S-4 order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (BOGE publishes none, so this validator produces no price build-up or line-item quote), supply voltage, mounting (base or tank), controller options, air-cooled versus water-cooled and other series, none of which the one-page data sheet specifies.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A delivery range that depends on model and pressure | Only with workarounds 13 model and pressure rows, each with its own delivery range; in a rules-based CPQ that becomes a lookup table kept in step with the data sheet. | The model, the pressure and the plant demand are checked together and the range for that row is returned. |
| A model that is not offered at a pressure | Only with care The fixed-speed S 55-4 L(D) exists at 7.5 bar only; a dependent picklist can hide it but only if someone maintains the list. | Any combination outside the offered set is reported in the same answer as every other problem. |
| A weight that depends on dryer and sound insulation | Only with workarounds Four weights per model; the figure typed into the quote has to be compared with the right one by hand. | The stated weight is a field in the request and is compared with the data sheet figure for the chosen version. |
| A width that grows by about 470 mm with the dryer | Only with care The room check needs the dryer choice and the model; each is another rule to keep. | Width, depth and height are checked against the room in the same call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The data sheet lists no unit for this model at this pressure; the fixed-speed S 55-4 L(D) is listed at 7.5 bar only. |
| 2 | The plant needs 8,701 L/min of free air; this unit at this pressure delivers at most 8,700 L/min. |
| 3 | The plant needs 5,500 L/min of free air; this unit at this pressure delivers at most 4,600 L/min. |
| 4 | The plant needs 2,000 L/min, below the 2,440 L/min where the effective delivery range of this unit starts; a person should confirm the unit is not oversized. |
| 5 | The quote states a maximum delivery of 9,000 L/min, but the data sheet gives 8,700 L/min for this model and pressure. |
| 6 | The quote states a weight of 1,950 kg, but the data sheet gives 1,770 kg for this version and sound insulation. |
| 7 | The quote states a weight of 1,770 kg, but the data sheet gives 1,950 kg for this version and sound insulation. |
| 8 | The piping on the quote does not match the compressed-air outlet of this model, which is G 1 1/2 on the S 38-4 and S 45-4 and DN 65 on the S 55-4 and S 75-4. |
| 9 | The unit is 2,570 mm wide; the installation space is 2,550 mm wide. |
| 10 | The unit is 1,200 mm deep; the installation space is 1,100 mm deep. |
| 11 | The unit is 1,720 mm high; the installation space is 1,700 mm high. |
| 12 | The quote states a maximum delivery of 6,010 L/min, but the data sheet gives 4,600 L/min for this model and pressure. |
| 13 | The quote states a weight of 1,345 kg, but the data sheet gives 1,555 kg for this version and sound insulation. |
| 14 | The unit is 2,550 mm wide; the installation space is 2,100 mm wide. |
| 15 | The unit is 1,200 mm deep; the installation space is 1,000 mm deep. |
| 16 | The unit is 1,720 mm high; the installation space is 1,600 mm high. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a BOGE S 38-4 LF compressor at 13 bar for a plant that needs 5,500 L/min of free air. The compressed-air piping is G 1 1/2. The installation space is 3,000 mm wide, 1,500 mm deep and 2,200 mm high. The quote states a maximum delivery of 5,500 L/min and a weight of 1,345 kg. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a BOGE S 45-4 LF compressor at 13 bar for a plant that needs 5,500 L/min of free air. The compressed-air piping is G 1 1/2. The installation space is 3,000 mm wide, 1,500 mm deep and 2,200 mm high. The quote states a maximum delivery of 6,040 L/min and a weight of 1,365 kg. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a BOGE S 55-4 LFD compressor at 10 bar for a plant that needs 4,500 L/min of free air. The compressed-air piping is G 1 1/2. The installation space is 2,550 mm wide, 1,400 mm deep and 2,100 mm high. The order includes the integrated dryer. The quote states a maximum delivery of 8,700 L/min and a weight of 1,950 kg. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a BOGE S 38-4 LFD compressor at 10 bar for a plant that needs 4,500 L/min of free air. The compressed-air piping is G 1 1/2. The installation space is 2,550 mm wide, 1,400 mm deep and 2,100 mm high. The order includes the integrated dryer. The quote states a maximum delivery of 6,010 L/min and a weight of 1,555 kg. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a BOGE S 55-4 LD compressor at 10 bar for a plant that needs 9,500 L/min of free air. The compressed-air piping is DN 65. The installation space is 3,000 mm wide, 1,500 mm deep and 2,200 mm high. The order includes super sound insulation and the integrated dryer. The quote states a maximum delivery of 10,010 L/min and a weight of 2,250 kg. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a BOGE S 75-4 LFD compressor at 10 bar for a plant that needs 9,500 L/min of free air. The compressed-air piping is DN 65. The installation space is 3,000 mm wide, 1,500 mm deep and 2,200 mm high. The order includes super sound insulation and the integrated dryer. The quote states a maximum delivery of 11,710 L/min and a weight of 1,990 kg. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a BOGE S 75-4 LF compressor at 13 bar for a plant that needs 10,000 L/min of free air. The compressed-air piping is DN 65. The installation space is 3,000 mm wide, 1,500 mm deep and 2,200 mm high. The quote states a maximum delivery of 10,000 L/min and a weight of 1,770 kg. It is ready to send.
Verdict: Blocked.
The text of the narrated walkthrough, step by step.