Predictika · Water meter sizing and fit checks
An AI sales agent prepares a water utility's quote for Recordall Disc meters: the model, the flows the meter must handle, water temperature and pressure, the connection, the line size and the space in the meter pit. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the public Recordall Disc data sheets and returns a verdict, every reason and the figures it computed.
This validator models sizing and fit for Recordall Disc meters, not just the scenarios shown below.
Any Recordall Disc quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Badger Meter does not publish meter prices, so no price build-up or line-item quote is produced), other Badger Meter product lines, registers, AMI endpoints and options. Assumptions: the shortest laying length listed for each model is used for the space check, and where data sheets give no separate low-flow limit the start of the operating range is used.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Flow limits that differ for each of six models | Only with care Each model has its own operating range and continuous rating, so every limit has to be set per model and kept in step with the data sheets. | The model and the flows are in one request and compared together on every call. |
| A stated capacity that disagrees with the model | Only with workarounds Checking a figure typed on the quote against the rating of the chosen model takes extra formulas. | The stated figure is one more field in the request and is compared with the model's rating on every call. |
| A low flow that is acceptable only with a person's sign-off | Only with care Three outcomes for one number (fine, review, block) depending on the model. | The lowest flow is checked against both limits and returns the right outcome with the other findings. |
| Connection type that depends on the model | Easy A compatibility rule between model and connection; routine in a product-rules CPQ. | The same rule, checked together with all the others on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The peak flow is 71 gpm; this model measures up to 70 gpm. |
| 2 | The continuous flow is 26 gpm; this model is rated for 25 gpm continuous. |
| 3 | The lowest flow to be measured is 2 gpm, below the 2.5 gpm start of the full-accuracy range; the data sheet gives reduced accuracy there, so a person should confirm. |
| 4 | The lowest flow to be measured is 1 gpm; this model measures down to 1.25 gpm. |
| 5 | The continuous flow is 101 gpm; this model is rated for 100 gpm continuous. |
| 6 | The water temperature is 81 F; Recordall Disc meters are rated to 80 F. |
| 7 | The line pressure is 151 psi; Recordall Disc meters are rated to 150 psi. |
| 8 | Model 25, 35, 55 and 70 meters connect through tailpiece threads; the quote selects a flanged or internally threaded connection. |
| 9 | Model 120 and 170 meters connect with AWWA flanges or internal pipe threads; the quote selects tailpiece threads. |
| 10 | The line size is 1.5 inch; this model fits 1 to 1 inch connections. |
| 11 | The line size is 1 inch; this model fits 0.5 to 0.75 inch connections. |
| 12 | The available space is 7 inch; this model needs at least 7.5 inch of laying length. |
| 13 | The quote states 30 gpm of continuous capacity; this model is rated for 25 gpm. |
| 14 | The lowest flow to be measured is 0.5 gpm; this model measures down to 0.75 gpm. |
| 15 | The peak flow is 40 gpm; this model measures up to 25 gpm. |
| 16 | The continuous flow is 30 gpm; this model is rated for 15 gpm continuous. |
| 17 | The water temperature is 100 F; Recordall Disc meters are rated to 80 F. |
| 18 | The line pressure is 200 psi; Recordall Disc meters are rated to 150 psi. |
| 19 | The lowest flow to be measured is 1.5 gpm, below the 2.5 gpm start of the full-accuracy range; the data sheet gives reduced accuracy there, so a person should confirm. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 120 Recordall Disc Model 25 meters for Cedar Ridge Water Utility, on 1-inch lines with tailpiece threads. Peak flow is 40 gpm, continuous flow is 30 gpm and the lowest flow to read is 0.75 gpm. The water is 60 F at 90 psi, and there are 7.5 inches of space for each meter. The quote states 15 gpm of continuous capacity. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 120 Recordall Disc Model 55 meters for Cedar Ridge Water Utility, on 1-inch lines with tailpiece threads. Peak flow is 40 gpm, continuous flow is 30 gpm and the lowest flow to read is 1.5 gpm. The water is 60 F at 90 psi, and there are 10.75 inches of space for each meter. The quote states 40 gpm of continuous capacity. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 6 Recordall Disc Model 170 meters for Lakeshore Commerce Park, on 2-inch lines with tailpiece threads. Peak flow is 150 gpm, continuous flow is 90 gpm and the lowest flow to read is 1 gpm. The water is 60 F at 170 psi, and there are 16 inches of space for each meter. The quote states 100 gpm of continuous capacity. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 6 Recordall Disc Model 170 meters for Lakeshore Commerce Park, on 2-inch lines with AWWA flanges. Peak flow is 150 gpm, continuous flow is 90 gpm and the lowest flow to read is 2 gpm. The water is 60 F at 140 psi, and there are 16 inches of space for each meter. The quote states 100 gpm of continuous capacity. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 6 Recordall Disc Model 170 meters for Lakeshore Commerce Park, on 2-inch lines with AWWA flanges. Peak flow is 150 gpm, continuous flow is 90 gpm and the lowest flow to read is 2.5 gpm. The water is 60 F at 140 psi, and there are 16 inches of space for each meter. The quote states 100 gpm of continuous capacity. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 8 Recordall Disc Model 120 meters for Pinecrest Municipal Water, on 1-1/2-inch lines with AWWA flanges. Peak flow is 100 gpm, continuous flow is 70 gpm and the lowest flow to read is 3 gpm. The water is 60 F at 120 psi, and there are 12 inches of space for each meter. The quote states 90 gpm of continuous capacity. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 8 Recordall Disc Model 120 meters for Pinecrest Municipal Water, on 1-1/2-inch lines with AWWA flanges. Peak flow is 100 gpm, continuous flow is 70 gpm and the lowest flow to read is 3 gpm. The water is 60 F at 120 psi, and there are 13 inches of space for each meter. The quote states 80 gpm of continuous capacity. It is ready to send.
Verdict: Allowed.