Predictika · Industrial vacuum pumps
An AI sales agent prepares an order for oil-free rotary vane vacuum pumps: the VTLF model, the supply frequency, the three-phase motor version, UL/CSA or NEMA requirements, optional variants and accessories, and the suction air, vacuum, sound, power and weight the customer needs. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures in public Becker data sheets and returns a verdict, every reason and the figures it computed.
This validator models one VTLF pump order at a time, based on public Becker VTLF US data sheets, and handles any order that uses these models, not just the scenarios shown below.
Any VTLF order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the data sheets publish none, so this page shows no price build-up), the VTLF 2.360, other Becker pump families, accessory dimensions and connection sizes, and the effect of each accessory on performance.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Motor versions that exist only at some frequencies (motor 2 is listed at 60 Hz only, motor 3 at 60 Hz only) | Only with workarounds A table of valid model, motor and frequency combinations, kept in step with five data sheets; a motor that is fine at 60 Hz is silently wrong at 50 Hz. | Model, motor number and frequency arrive in one request and are checked against the listed table on every call. |
| Suction air that depends on frequency and pump count | Only with care The rate per pump changes with the supply frequency, then multiplies by the number of pumps and is compared with the requirement and with the figure the quote states. | The requirement, the computed total and the stated total are compared on every call. |
| An inverter version listed for two of the five models | Only with care VARIAIR must be allowed on the VTLF 2.250 and 2.500 only, and still interacts with the other options. | The option and the model are checked together, whatever order they were chosen in. |
| Limits across several figures (vacuum, sound, power budget, total weight) | Only with workarounds Each limit depends on the model, the frequency and the motor, and totals depend on the pump count, so rules multiply. | Every limit is computed from the selected model, motor and quantity and compared on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The order has 0 pumps; at least 1 is needed. |
| 2 | The order needs 300 CFM of suction air; the pumps give 0 CFM in total. |
| 3 | The data sheets give figures for 50 Hz and 60 Hz supply; the order has 55 Hz. |
| 4 | The data sheet for this model lists no motor number 6. |
| 5 | The data sheet for this model lists no motor number 8. |
| 6 | Motor number 2 for this model is not listed for the supply frequency of 50 Hz. |
| 7 | Motor number 3 for this model is not listed for the supply frequency of 50 Hz. |
| 8 | UL and CSA listing is required, and the selected motor is not listed as UL and CSA. |
| 9 | A NEMA motor is required, and the selected motor is not a NEMA version. |
| 10 | The order needs 339 CFM of suction air; the pumps give 338 CFM in total. |
| 11 | The order needs 289 CFM of suction air; the pumps give 288 CFM in total. |
| 12 | The order needs 24.0 in. HgV of vacuum; this model reaches 23.6 in. HgV. |
| 13 | The order needs 26.6 in. HgV of vacuum; this model reaches 23.6 in. HgV. |
| 14 | The order needs 22.2 in. HgV of vacuum; this model reaches 22.1 in. HgV. |
| 15 | The model gives 79 dB(A) at this supply frequency; the limit is 78 dB(A) and no sound proof box is quoted. |
| 16 | The model gives 79 dB(A) against a limit of 76 dB(A); the sound proof box is described on a separate data sheet, and a person should confirm it brings the level within the limit. |
| 17 | The VARIAIR frequency inverter version is listed only for the VTLF 2.250 and the VTLF 2.500. |
| 18 | The data sheets say possible combinations of variants and accessories are available on request; a person should confirm this combination of 2 options. |
| 19 | The data sheets say possible combinations of variants and accessories are available on request; a person should confirm this combination of 3 options. |
| 20 | 2 pumps with motors of 8.9 hp each need 17.8 hp in total; the budget is 17.7 hp. |
| 21 | 3 pumps with motors of 25.0 hp each need 75.0 hp in total; the budget is 50.0 hp. |
| 22 | The pumps with their motors weigh 2715.3 lb in total; the limit is 2,000 lb. |
| 23 | The pumps with their motors weigh 1115.8 lb in total; the limit is 1,100 lb. |
| 24 | The order states 350 CFM of suction air in total; the pumps give 338 CFM. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 2 VTLF 2.200 vacuum pumps on a 50 Hz supply, with motor version 1. The order needs 300 CFM of suction air in total and 20.0 in. HgV of vacuum, and states 210 CFM in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 3 VTLF 2.200 vacuum pumps on a 50 Hz supply, with motor version 1. The order needs 300 CFM of suction air in total and 20.0 in. HgV of vacuum, and states 315 CFM in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 2 VTLF 2.250 vacuum pumps on a 60 Hz supply, with motor version 1. The order needs 300 CFM of suction air in total and 24.0 in. HgV of vacuum, and states 338 CFM in total. The motor must be UL and CSA listed. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 VTLF 2.250 vacuum pumps on a 60 Hz supply, with motor version 3. The order needs 300 CFM of suction air in total and 24.0 in. HgV of vacuum, and states 338 CFM in total. The motor must be UL and CSA listed. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 VTLF 2.250 SK vacuum pumps on a 60 Hz supply, with motor version 3. The order needs 300 CFM of suction air in total and 24.0 in. HgV of vacuum, and states 348 CFM in total. The motor must be UL and CSA listed. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 VTLF 2.400 vacuum pumps on a 60 Hz supply, with motor version 1. The order needs 300 CFM of suction air in total and 20.0 in. HgV of vacuum, and states 270 CFM in total. Include: VARIAIR frequency inverter version. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 VTLF 2.500 vacuum pumps on a 60 Hz supply, with motor version 1. The order needs 300 CFM of suction air in total and 20.0 in. HgV of vacuum, and states 336 CFM in total. Include: VARIAIR frequency inverter version. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.