Predictika · Surgical electrosurgery quotes
An AI sales agent prepares a quote for the CONMED HelixAR electrosurgical generator with argon beam coagulation (ABC) technology: the generator or system, the ABC handpieces and probes, the dissecting electrodes, the argon, the footswitch, the endoscope channel and trocar sizes, the discount and the net total the quote states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of how those products fit together and returns a verdict, every reason and the total it computed.
This validator models HelixAR ABC quotes, not just the scenarios shown below.
Any HelixAR ABC quote that touches these rules is in scope — not only the scenarios pictured here. The product names, catalog numbers and handpiece types follow CONMED's public web pages and brochures. CONMED publishes no prices here: the prices, the discount limits, the argon, footswitch, endoscope channel and trocar rules and the approvals are modeled from comparable products and are not published by CONMED.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Accessories that depend on other accessories | Only with care A new system needs argon, foot control devices need a footswitch, a reusable handpiece needs a nozzle each and dissecting electrodes need a compatible handpiece, so one missing line blocks the quote. | Every dependency is checked in the same pass, whatever order the lines arrive. |
| Fit with the clinical setup | Only with care A GI probe needs a large enough endoscope channel and a laparoscopic probe needs a large enough trocar, so a size stated elsewhere changes which probes are allowed. | The sizes are checked against the probes on every call. |
| A stated total that must match the computed one | Only with workarounds The price depends on the generator, every quantity and the discount, so a rule must recompute it and compare it with the stated figure. | The total is computed inside the model and compared with the stated one. |
| Approval bands | Only with workarounds A discount above 10 percent, equipment the customer already owns and an unstated endoscope channel are not refused but need a person, so each needs a third outcome besides yes and no. | The model returns allow, needs approval or block for each band. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, so the agent can fix them in a single pass. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote states a net total of $1,234.50 but the quoted products give $24,894.75. |
| 2 | The quote has ABC handpieces, probes or electrodes but no HelixAR generator, new or existing. |
| 3 | The quote relies on a generator the customer already owns; a person should confirm it is a HelixAR or other ABC-capable unit. |
| 4 | A new HelixAR system needs argon (D-size cylinder) on the quote or a customer argon supply; the quote has neither. |
| 5 | The quote has 3 foot-control handpiece(s) or probe(s) but no ABC footswitch, new or existing. |
| 6 | Foot-control devices rely on a footswitch the customer already owns; a person should confirm it works with the generator. |
| 7 | The reusable foot control handpiece (130500) needs a single-use ABC nozzle (130343) each; the quote has 2 handpiece(s) and 0 nozzle(s). |
| 8 | Dissecting electrodes are used only with the Single Function, Angled foot control, nozzle-equipped reusable or 10 mm laparoscopic devices; the quote has none. |
| 9 | The ABCFlex GI probe 133327 is for the System 7550, not the HelixAR; the quote has 1. |
| 10 | The 2.3 mm ABCFlex GI probe needs an endoscope working channel of at least 2.8 mm; the stated channel is 2.0 mm. |
| 11 | ABCFlex GI probes are quoted but no endoscope channel size is stated; a person should confirm the endoscope. |
| 12 | The 10 mm laparoscopic ABC probe needs a 10 mm or larger trocar; the stated trocar is 5 mm. |
| 13 | The discount is 15 percent; discounts over 10 percent need sales management approval. |
| 14 | The discount is 25 percent; discounts over 20 percent cannot be quoted. |
| 15 | The quote has no products. |
| 16 | The 5 mm laparoscopic ABC probes need a 5 mm or larger trocar; the stated trocar is 4 mm. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote the HelixAR generator set (60-8800-SET) with 4 units of hand control handpiece (130321), 3 units of Angled foot control handpiece (130345), 2 units of reusable foot control handpiece (130500), 2 units of 10 mm laparoscopic probe (130342), 1 ABCFlex GI probe (133270) and 5 units of dissecting electrode (139330). The endoscope channel is 2.0 mm. The trocar is 5 mm. The discount is 25 percent. The quote states a net total of $30,000.00. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote the HelixAR generator set (60-8800-SET) with 4 units of hand control handpiece (130321), 3 units of Angled foot control handpiece (130345), 2 units of reusable foot control handpiece (130500), 2 units of single-use nozzle (130343), 2 units of 10 mm laparoscopic probe (130342), 1 ABCFlex GI probe (133270), 5 units of dissecting electrode (139330), 2 units of argon cylinder (136050) and 1 wired footswitch. The endoscope channel is 3.2 mm. The trocar is 10 mm. The discount is 15 percent. The quote states a net total of $30,000.00. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote the HelixAR generator set (60-8800-SET) with 4 units of hand control handpiece (130321), 3 units of Angled foot control handpiece (130345), 2 units of reusable foot control handpiece (130500), 2 units of single-use nozzle (130343), 2 units of 10 mm laparoscopic probe (130342), 1 ABCFlex GI probe (133270), 5 units of dissecting electrode (139330), 2 units of argon cylinder (136050) and 1 wired footswitch. The endoscope channel is 3.2 mm. The trocar is 10 mm. The discount is 10 percent. The quote states a net total of $25,618.50. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a generator the customer already owns with 2 units of hand control handpiece (130321), 2 units of Bend-a-Beam handpiece (134006) and 5 units of dissecting electrode (139330). The discount is 0 percent. The quote states a net total of $925.00. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote the HelixAR generator set (60-8800-SET) with 2 units of hand control handpiece (130321), 2 units of Single Function handpiece (130344), 2 units of Bend-a-Beam handpiece (134006), 5 units of dissecting electrode (139330), 2 units of argon cylinder (136050) and 1 wired footswitch. The discount is 0 percent. The quote states a net total of $26,400.00. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote the HelixAR system (60-8800-SYS) with 2 units of hand control handpiece (130321), 1 ABCFlex GI probe (133327), 2 units of argon cylinder (136050) and 1 wired footswitch. The discount is 0 percent. The quote states a net total of $28,335.00. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote the HelixAR system (60-8800-SYS) with 2 units of hand control handpiece (130321), 1 ABCFlex GI probe (133270), 2 units of argon cylinder (136050) and 1 wired footswitch. The endoscope channel is 3.2 mm. The discount is 0 percent. The quote states a net total of $28,335.00. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.