Predictika · Radiant heating and hydronic components
An AI sales agent prepares an order for pre-assembled TwistFlow radiant distribution manifolds: the pipe size, the number of manifolds and outlets, the circuits the customer needs to connect, the design flow per circuit, the fluid and its glycol content, pressures, temperature and the total outlets it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the limits Caleffi publishes in its data sheet and returns a verdict, every reason and the figures it computed.
This validator models an order for TwistFlow 668S1 series manifolds of one configuration at a time, based on the limits in the public Caleffi data sheet, not just the scenarios shown below.
Any TwistFlow 668S1 manifold order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Caleffi does not publish list prices, so this page shows no price build-up), other Caleffi manifolds and series, actuators, weights and lengths, and the hydraulic design of the radiant system itself. The data sheet remains the final authority.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Outlet count that must cover the circuits and stay within the series range | Only with care Circuits needed against outlets per manifold, and the 3 to 13 range, are simple rules, but they are checked in different steps of a typical configuration. | Outlets, circuits and the range are compared together on every call. |
| Several operating limits at once (glycol, pressure, discharge pressure, temperature) | Only with workarounds Each limit is its own validation rule that fires when the order is saved, so a person often fixes one error and meets the next. | All limits are checked together and every finding comes back in one answer. |
| Glycol percentage that only makes sense with a glycol solution | Only with care A dependency between two fields that has to be written and kept in step. | The fluid and the glycol content are in one request and checked with everything else. |
| Outlets in total against what the order states | Only with care Total outlets are manifolds times outlets, then compared with a total typed into the order. | The total is computed and compared on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The 668S1 series is offered with 3 to 13 outlets; the quote has 2. |
| 2 | The 668S1 series is offered with 3 to 13 outlets; the quote has 14. |
| 3 | The customer has 7 radiant circuits to connect; the quoted manifold has 6 outlets. |
| 4 | The design flow of 24 hundredths of a gallon per minute per circuit is below the flow meter scale, which starts at 1/4 GPM. |
| 5 | The design flow of 201 hundredths of a gallon per minute per circuit is above the flow meter scale, which ends at 2 GPM. |
| 6 | The data sheet lists water and glycol solutions as the medium; a person should confirm the customer fluid with Caleffi. |
| 7 | The glycol content is 51 percent; the maximum is 50 percent. |
| 8 | The quote states 20 percent glycol but the medium is plain water. |
| 9 | The working pressure is 151 psi; the maximum is 150 psi. |
| 10 | The end fitting discharge pressure is 36 psi; the maximum is 35 psi. |
| 11 | The working temperature is 181 degrees Fahrenheit; the range is 32 to 180. |
| 12 | The working temperature is 31 degrees Fahrenheit; the range is 32 to 180. |
| 13 | The customer needs flow accuracy within 10 percent; the flow meter is accurate to plus or minus 15 percent. |
| 14 | The quote states 10 outlets in total; the quoted manifolds give 12. |
| 15 | The quote has 0 manifolds; at least 1 is needed. |
| 16 | The customer has 15 radiant circuits to connect; the quoted manifold has 14 outlets. |
| 17 | The design flow of 220 hundredths of a gallon per minute per circuit is above the flow meter scale, which ends at 2 GPM. |
| 18 | The glycol content is 60 percent; the maximum is 50 percent. |
| 19 | The working pressure is 160 psi; the maximum is 150 psi. |
| 20 | The end fitting discharge pressure is 40 psi; the maximum is 35 psi. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 4 TwistFlow 1 1/4 inch manifolds with 14 outlets each for a customer with 12 radiant circuits. The design flow is 2.20 GPM per circuit, the fluid is a glycol solution (30 percent glycol), working pressure is 80 psi, discharge pressure at the end fittings is 25 psi, working temperature is 130 degrees Fahrenheit and the customer needs flow accuracy within 15 percent. The order states 48 outlets in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 4 TwistFlow 1 1/4 inch manifolds with 12 outlets each for a customer with 12 radiant circuits. The design flow is 1.80 GPM per circuit, the fluid is a glycol solution (30 percent glycol), working pressure is 80 psi, discharge pressure at the end fittings is 25 psi, working temperature is 130 degrees Fahrenheit and the customer needs flow accuracy within 15 percent. The order states 48 outlets in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 3 TwistFlow 1 inch manifolds with 8 outlets each for a customer with 8 radiant circuits. The design flow is 1.20 GPM per circuit, the fluid is a glycol solution (55 percent glycol), working pressure is 160 psi, discharge pressure at the end fittings is 20 psi, working temperature is 190 degrees Fahrenheit and the customer needs flow accuracy within 15 percent. The order states 30 outlets in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 3 TwistFlow 1 inch manifolds with 8 outlets each for a customer with 8 radiant circuits. The design flow is 1.20 GPM per circuit, the fluid is a glycol solution (50 percent glycol), working pressure is 150 psi, discharge pressure at the end fittings is 20 psi, working temperature is 190 degrees Fahrenheit and the customer needs flow accuracy within 15 percent. The order states 30 outlets in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 3 TwistFlow 1 inch manifolds with 8 outlets each for a customer with 8 radiant circuits. The design flow is 1.20 GPM per circuit, the fluid is a glycol solution (50 percent glycol), working pressure is 150 psi, discharge pressure at the end fittings is 20 psi, working temperature is 170 degrees Fahrenheit and the customer needs flow accuracy within 15 percent. The order states 24 outlets in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 5 TwistFlow 1 inch manifolds with 10 outlets each for a customer with 12 radiant circuits. The design flow is 1.00 GPM per circuit, the fluid is a glycol solution (25 percent glycol), working pressure is 70 psi, discharge pressure at the end fittings is 20 psi, working temperature is 140 degrees Fahrenheit and the customer needs flow accuracy within 10 percent. The order states 40 outlets in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 5 TwistFlow 1 inch manifolds with 12 outlets each for a customer with 12 radiant circuits. The design flow is 1.00 GPM per circuit, the fluid is a glycol solution (25 percent glycol), working pressure is 70 psi, discharge pressure at the end fittings is 20 psi, working temperature is 140 degrees Fahrenheit and the customer needs flow accuracy within 15 percent. The order states 60 outlets in total. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.