Predictika · Telecom infrastructure site orders
An AI sales agent prepares a site order for telecom infrastructure services: co-location on a tower, cabin or ground space or a build-to-suit programme, the equipment weight, antennas and power per site, cooling and backup power, the tenants already on the site, the backhaul, the term, small-cell nodes and the total power the order states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of what each site type can carry and how those choices fit together, and returns a verdict, every reason and the total it computed.
This validator models tower, cabin and ground-space site orders, not just the scenarios shown below.
Any site order of these types that touches these rules is in scope — not only the scenarios pictured here. Not covered: broadcasting, network services and pricing; this model has no prices. The service set (co-location on towers, cabins and ground, power with cooling and backup power, small cells and DAS, build-to-suit towers, backhaul by fibre or radio and edge data centres) follows public Cellnex descriptions; every limit, threshold and term in this validator is modeled from comparable tower-company offers and is not published by Cellnex.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Limits that change with the site type | Only with care A tower, a cabin and a ground site each take a different weight, number of antennas, power and tenants, so every rule has to test the site type first. | The site type sets every limit in the same pass as the equipment on the order. |
| Options that only some sites can take | Only with care Backup power needs a cabin or ground site, an edge unit needs ground space and radio backhaul needs a tall tower, each with its own exceptions. | The site type, the options and the tower height are checked together on every call. |
| Thresholds that start a review | Only with workarounds A last tenant slot, a fibre run over 2,000 metres, a short term, a large small-cell count and a big programme each need a person, so each needs its own rule and message. | Each threshold is part of the model and returns its own approval with the reason. |
| A stated total that must match the computed one | Only with workarounds The total power is the sites times the power per site, so a separate rule must recompute it and compare it with the stated figure. | The stated total is a field of the request and is compared with the computed total on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, so the agent can fix them in a single pass. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the order; approval findings need a person to sign off; everything else is computed.
| 1 | The equipment weighs 801 kg; this site type allows 800 kg per tenant. |
| 2 | Equipment above half the tower load limit needs a completed structural study; none is recorded. |
| 3 | The order has 7 antennas; this site type allows 6 per tenant. |
| 4 | The equipment needs 4 kW per site; this site type supplies 3 kW per tenant. |
| 5 | Equipment above 3 kW per site needs the cooling service; the order does not include it. |
| 6 | The uninterrupted power supply is housed in a cabin or ground site; it cannot be added to a tower mount. |
| 7 | This order takes the last available tenant slot on the site; a person should confirm. |
| 8 | The site already has 4 tenants; this site type takes at most 4. |
| 9 | The antennas are requested at 41 m; the tower is 40 m high. |
| 10 | Radio backhaul is modeled for towers of at least 25 m; this site does not qualify. |
| 11 | A fibre run of 2,001 m needs a route survey; a person should confirm. |
| 12 | The fibre run is 10,001 m; fibre-to-the-tower is modeled up to 10,000 m. |
| 13 | A term of 4 years is below the 5-year minimum. |
| 14 | A term of 7 years is shorter than the standard 10-year term; a person should confirm. |
| 15 | Build-to-suit is modeled for new towers only. |
| 16 | Build-to-suit needs a term of at least 10 years; the order has 8. |
| 17 | A build-to-suit programme of 60 sites needs a person to confirm delivery capacity. |
| 18 | An edge data centre unit needs ground space; this site is not ground space. |
| 19 | 51 DAS or small-cell nodes is a large deployment; a person should review the design. |
| 20 | 201 DAS or small-cell nodes is above the 200 modeled for one order. |
| 21 | The order states 25 kW of total power; the sites add up to 20 kW. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please prepare a co-location order for 10 sites on towers, with 900 kg of equipment, 8 antennas and 5 kW of power at each site, the antennas at 48 m on a 40 m tower, with an uninterrupted power supply and a completed structural study, fibre backhaul over 3,500 m, 0 tenants already on the site, for a term of 10 years. The order states 30 kW of total power. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a co-location order for 10 sites on cabins, with 900 kg of equipment, 3 antennas and 4 kW of power at each site, with an uninterrupted power supply and a completed structural study, fibre backhaul over 3,500 m, 0 tenants already on the site, for a term of 10 years. The order states 40 kW of total power. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a co-location order for 10 sites on cabins, with 900 kg of equipment, 3 antennas and 4 kW of power at each site, with cooling, an uninterrupted power supply and a completed structural study, fibre backhaul over 1,500 m, 0 tenants already on the site, for a term of 10 years. The order states 40 kW of total power. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare a build-to-suit programme for 60 sites on cabins, with 500 kg of equipment, 4 antennas and 3 kW of power at each site, for a term of 8 years. The order states 150 kW of total power. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a build-to-suit programme for 20 sites on new towers, with 500 kg of equipment, 4 antennas and 3 kW of power at each site, the antennas at 45 m on a 45 m tower, for a term of 15 years. The order states 60 kW of total power. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare a co-location order for 10 sites on towers, with 300 kg of equipment, 3 antennas and 2 kW of power at each site, the antennas at 35 m on a 40 m tower, fibre backhaul over 12,000 m, 250 small-cell nodes, 1 tenant already on the site, for a term of 4 years. The order states 20 kW of total power. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a co-location order for 10 sites on towers, with 300 kg of equipment, 3 antennas and 2 kW of power at each site, the antennas at 35 m on a 40 m tower, fibre backhaul over 1,500 m, 40 small-cell nodes, 1 tenant already on the site, for a term of 10 years. The order states 20 kW of total power. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.