Predictika · Residential garage door orders
An AI sales agent prepares an order for a steel garage door from the Gallery Collection: model, door width, wind code, windows, finish and the code approvals the project needs. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published availability chart and returns a verdict, every reason and the figures it computed.
This validator models orders for ten Gallery Collection garage door models (GD2SU, GD2LU, GD1SU, GD1LU, GD2SP, GD2LP, GD1SP, GD1LP, GD4S and GD4L), not just the scenarios shown below.
Any order for these ten models that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Clopay doors are sold through dealers and no price list is published, so this validator produces no price build-up or line-item quote), the models GD4SV, GD4LV, GD5S and GD5SV and the 25 gauge pan models (no wind code chart row is tied to them in the source), hardware, opener and other collections, and window styles beyond standard windows.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Wind codes offered only for some models and widths | Only with workarounds The chart is a grid of about 280 model, width and wind code cells; in a rules-based CPQ it becomes a long list of per-combination rules or a lookup table that someone has to keep in step with the brochure. | The grid is part of one model, so any combination of model, width and wind code is checked with no extra rules. |
| A wind code that is replaced by another one | Only with care Each substitution (W3 to W4, W4 to W5, W5 to W6, W7 to W8) depends on the model and width, so each needs its own message and its own condition. | The finding names the code to select instead, whatever the model and width. |
| Approvals and ratings that depend on the exact combination | Only with workarounds Florida, Dade County and Texas approvals, impact rating and pressure ratings all vary by cell, so each is another table to maintain and compare with the project requirement. | Each approval and pressure rating comes from the same cell and is compared with the project requirement on every call. |
| Stated figures that must match the model and the chart | Only with care A stated R-value or pressure rating is a free-entry field; a rule can compare it with the computed one, but someone has to write and maintain that comparison. | The stated figures travel with the order and are compared with the computed figures on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | Wind code W3 is not offered for this model at this door width; the chart says to select W4 instead. |
| 2 | Wind code W4 is not offered for this model at this door width; the chart says to select W5 instead. |
| 3 | Wind code W5 is not offered for this model at this door width; the chart says to select W6 instead. |
| 4 | Wind code W7 is not offered for this model at this door width; the chart says to select W8 instead. |
| 5 | The selected wind code is not available for this model at this door width; no rating is published for it. |
| 6 | The project needs a positive design pressure of 26 psf, but this model, door width and wind code is rated for 25.5 psf. |
| 7 | The project needs a negative design pressure of 26 psf, but this model, door width and wind code is rated for 25.5 psf. |
| 8 | Standard windows are not available with this model, door width and wind code. |
| 9 | The project requires Florida product approval, but this model, door width and wind code is not Florida approved. |
| 10 | The project requires Miami-Dade County approval, but this model, door width and wind code is not Dade County approved. |
| 11 | The project requires Texas Department of Insurance approval, but this model, door width and wind code is not approved by it. |
| 12 | The project requires an impact-rated door, but this model, door width and wind code is not impact rated. |
| 13 | Ultra-Grain finishes are available on 3-layer doors only, and the selected model is not a 3-layer door. |
| 14 | The project requires a section R-value of at least 9, but the selected model is rated R-6.5. |
| 15 | The project requires an insulated door with an R-value, but the selected model is not insulated. |
| 16 | The quote states an R-value of 18.4, but the selected model is rated R-12.9. |
| 17 | The quote states an R-value of 9, but the selected model is not insulated and has no R-value. |
| 18 | The quote states a positive design pressure rating of 30 psf, but the chart rating for this model, door width and wind code is 28 psf. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote one 10 ft wide Gallery GD4S (short panel, non-insulated, 1-layer) in Ultra-Grain Walnut, wind code W3, with standard windows, for a project that needs design pressures of +25 and -25 psf and a section R-value of at least 9. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote one 10 ft wide Gallery GD4S (short panel, non-insulated, 1-layer) in Ultra-Grain Walnut, wind code W4, with standard windows, for a project that needs design pressures of +25 and -25 psf and a section R-value of at least 9. The quote states a positive design pressure rating of 25 psf. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote one 10 ft wide Gallery GD2LU (long panel, 2 in polyurethane, 3-layer) in Ultra-Grain Walnut, wind code W4, with standard windows, for a project that needs design pressures of +25 and -25 psf and a section R-value of at least 9. The quote states an R-value of R-18.4 and a positive design pressure rating of 25.5 psf. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote one 16 ft wide Gallery GD1LU (long panel, 1 3/8 in polyurethane, 3-layer) in Sandtone, wind code W5, with standard windows, for a project that needs design pressures of +30 and -30 psf, Florida product approval, an impact-rated door and a section R-value of at least 9. The quote states an R-value of R-12.9 and a positive design pressure rating of 30 psf. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote one 16 ft wide Gallery GD2SP (short panel, 2 in polystyrene, 3-layer) in Sandtone, wind code W6, with standard windows, for a project that needs design pressures of +30 and -30 psf, Florida product approval, an impact-rated door and a section R-value of at least 9. The quote states an R-value of R-9 and a positive design pressure rating of 37 psf. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote one 9 ft wide Gallery GD1SU (short panel, 1 3/8 in polyurethane, 3-layer) in Almond, wind code W4, with standard windows, for a project that needs design pressures of +28 and -29 psf. The quote states an R-value of R-18.4 and a positive design pressure rating of 30 psf. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote one 9 ft wide Gallery GD1SU (short panel, 1 3/8 in polyurethane, 3-layer) in Almond, wind code W4, with standard windows, for a project that needs design pressures of +28 and -29 psf. The quote states an R-value of R-12.9 and a positive design pressure rating of 28 psf. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.