Predictika · packaged rooftop units: capacity, airflow, voltage, heat, options, altitude, lead time and discount
An AI sales agent prepares a rooftop unit quote for a fictional customer. Before it goes out, the agent sends it to Predictika’s validator, which checks it against the product and contract rules, compares the net total the agent states with the one it computes, and returns a verdict with every reason.
This validator models Daikin Applied style packaged rooftop unit quotes with a unit size, voltage, heat type, required capacity and airflow, site altitude, electrical service, options, quantity, weeks needed and an extra discount. It handles any quote made of these units and options, not just the scenarios shown below.
It does not cover other Daikin Applied product families such as chillers and air handlers, field service and warranty terms, or real list prices.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ or Revenue Cloud) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator catches | Typical rules-based CPQ | Predictika |
|---|---|---|
| Capacity after an altitude derate against the capacity required | Only with workarounds Needs a derate table and a calculated field in the price and validation rules; the derate bands change with every engineering update. | The derate steps and the capacity check are one calculation with the block and the review. |
| Airflow range, voltage and heat combinations by unit size | Only with care Product rules per size and per option; works, but each new size needs its own rules. | Ranges and minimum levels are data on each unit; every check follows from them. |
| Minimum circuit ampacity against the electrical service | Only with workarounds Needs a calculated ampacity that depends on unit, voltage and heat, compared with a quote field. | Ampacity is computed from the unit, voltage and heat and compared with the service in one pass. |
| Wheel, coating, economizer and energy code dependencies | Only with care Option dependency rules; works, but the combinations multiply as options are added. | Each dependency is one rule on the chosen options, and all of them are returned together. |
| The net total the agent states | Only with workarounds Comparing a stated total with a computed one means a separate rule per quote layout, and price rules rarely run on stated figures. | The stated net total is a field in the request and is checked against the computed total. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in whatever order the choices arrive, and one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| Rule | Effect | What it checks |
|---|---|---|
| Capacity | block | Unit capacity after the altitude derate must meet the required MBH |
| Airflow | block | Required CFM within the range of the unit |
| Voltage | block | Units of 20 tons and above are offered only at 460 V or 575 V |
| Electric heat voltage | block | Electric heat on 27 kW and larger units is not offered at 208 V |
| Gas heat altitude | block | Gas heat not offered above 10000 feet |
| Energy wheel unit | block | Wheel only on 20 ton and larger units |
| Energy wheel economizer | block | Wheel needs the economizer section |
| Coastal | block | Coastal site needs the coating |
| Energy code | block | Strict code needs the economizer |
| Electrical service | block | Minimum circuit ampacity must not exceed the service available |
| Quantity | block | 1 to 100 units |
| Extra discount limit | block | Above 15 percent |
| Lead time block | block | More than 8 weeks beyond the weeks needed |
| Extra discount approval | needs approval | Above 8 percent within the limit |
| Lead time approval | needs approval | Longer than the weeks needed, within 8 weeks |
| High altitude | needs approval | Above 5000 feet needs engineering review |
| Large order | needs approval | Above USD 750000 needs regional manager review |
| Price | calculation | Unit price plus heat, economizer, wheel and coating adders, less volume and extra discounts, times quantity |
| Stated net total | block | The net total the agent states must match the total the validator computes (within USD 1). |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Two 10 ton rooftop units at 460 V with gas heat and an economizer for a site at 1,000 feet needing 140 MBH and 4,500 CFM. Net order value USD 50,200. Ready to send.
Verdict: Blocked.
The agent's request. Two 15 ton rooftop units at 460 V with gas heat and an economizer for a site at 1,000 feet needing 140 MBH and 4,500 CFM. Net order value USD 64,200. Ready to send.
Verdict: Allowed.
The agent's request. Four 20 ton rooftop units at 460 V with gas heat and an economizer for a site at 1,000 feet needing 200 MBH and 7,500 CFM. Net order value USD 146,520. Ready to send.
Verdict: Blocked.
The agent's request. Four 20 ton rooftop units at 460 V with gas heat and an economizer for a site at 1,000 feet needing 200 MBH and 7,500 CFM. Net order value USD 162,800. Ready to send.
Verdict: Allowed.
The agent's request. Four 20 ton rooftop units at 460 V with gas heat and no economizer, with a 20 percent extra discount, for a site under the strict energy code. Net order value USD 117,760. Ready to send.
Verdict: Blocked.
The agent's request. Four 20 ton rooftop units at 460 V with gas heat and an economizer, with a 10 percent extra discount, for a site under the strict energy code. Net order value USD 146,520. Ready to send.
Verdict: Needs approval.
The agent's request. Four 20 ton rooftop units at 460 V with gas heat and an economizer, with an 8 percent extra discount, for a site under the strict energy code. Net order value USD 149,776. Ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.