Predictika · Refrigeration component quotes
An AI sales agent drafts a quote for a refrigeration system: the compressor, the expansion valve, the frequency drive, the refrigerant, the application, the supply voltage, the load and the number of systems. Before the quote goes out, the agent sends it to Predictika, which checks it against a declarative model of the component capacities, refrigerants, voltages and discount authority, compares the net total the agent states with the one it computes, and reports every problem it finds in one pass.
This validator models refrigeration component selection quotes in the style of Danfoss, with five compressors, five expansion valves and five drive options. It handles any system made of these, not just the scenarios shown below.
Any refrigeration component quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: other Danfoss product lines, system design or thermodynamic calculations, or real list prices.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Compressor, valve and refrigerant match | Only with workarounds A product rule per refrigerant and component pairing; each new refrigerant multiplies the rules. | Refrigerant is a catalog attribute compared with the system on every call, for the compressor and the valve separately. |
| Capacity with a safety margin | Only with care A validation rule per compressor family; the margin is easy to hard-code differently in several places. | The capacity is compared with the load times the margin in one calculation. |
| Drive voltage, size and the 45 kW requirement | Only with workarounds Dependent selection rules between drive and compressor, usually added after the first field failure. | Drive voltage, drive size and the requirement are three separate findings returned together. |
| Low temperature and supply voltage | Only with care Attribute checks tied to the application and supply fields; often added late. | Each is a direct comparison of a catalog attribute with the quote field. |
| Volume discount stacked with an extra discount | Only with workarounds Stacked schedules and approval limits; double counting is common. | The total discount is one calculation; the approval band and the limit are separate findings. |
| The net total the agent states | Only with workarounds Comparing a stated value with a computed one means a separate rule per quote layout, and price rules rarely run on stated figures. | The stated net total is a field in the request and is checked against the computed value. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | Total discount of 9 percent is above the 8 percent a rep can give; sales director must approve. |
| 2 | A 40 kW system on a mildly flammable A2L refrigerant needs a charge and site safety review. |
| 3 | Project value of $78,320 is above $60,000 and needs a deal desk review. |
| 4 | The 20 kW Scroll compressor 20 kW HFC cannot cover a 20 kW load with the required 10 percent margin. |
| 5 | The Scroll compressor 20 kW HFC does not match the A2L refrigerant of this system. |
| 6 | The Electronic expansion valve 15 kW HFC does not match the A2L refrigerant of this system. |
| 7 | The Scroll compressor 20 kW HFC is not rated for low temperature application. |
| 8 | The Scroll compressor 20 kW HFC does not run on the V230 supply. |
| 9 | The Frequency drive 12 kW 230 V does not match the supply voltage of the Scroll compressor 20 kW HFC. |
| 10 | The Frequency drive 12 kW 230 V is too small for the Scroll compressor 20 kW HFC. |
| 11 | The Scroll compressor 45 kW A2L needs a frequency drive for soft start and capacity control. |
| 12 | The 15 kW Electronic expansion valve 15 kW HFC is too small for a 16 kW load. |
| 13 | 25 systems are outside the 1 to 20 systems of one quote. |
| 14 | Total discount of 16 percent exceeds the 15 percent limit. |
| 15 | The quoted net total of $4,389.60 does not match the $4,720 the validator computed. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. This is for a grocery chain adding a refrigeration system for a medium temperature load, built on an A2L refrigerant. One 20 kW scroll compressor with a 15 kW electronic expansion valve and a 20 kW 400 V frequency drive, for an A2L refrigerant system with a 14 kW medium temperature load. Net total $4,720. It is ready to send.
Verdict: Blocked.
The agent's request. This is for a grocery chain adding a refrigeration system for a medium temperature load, built on an A2L refrigerant. One 12 kW single phase A2L scroll compressor with a 15 kW A2L electronic expansion valve and a 12 kW 230 V frequency drive, for a 10 kW medium temperature load on a 230 V supply. Net total $3,350. It is ready to send.
Verdict: Allowed.
The agent's request. This is for a distribution center upgrading its air conditioning plant, a 38 kW load on a 400 V supply. One 45 kW A2L scroll compressor with a 40 kW A2L electronic expansion valve and no frequency drive, for an air conditioning system on a 400 V supply with a 38 kW load. Net total $5,890. It is ready to send.
Verdict: Blocked.
The agent's request. This is for a distribution center upgrading its air conditioning plant, a 38 kW load on a 400 V supply. One 45 kW A2L scroll compressor with a 40 kW A2L electronic expansion valve and a 60 kW 400 V frequency drive, for an air conditioning system with a 38 kW load. Net total $10,190. It is ready to send.
Verdict: Allowed.
The agent's request. This is for a cold storage operator adding a system for a 14 kW medium temperature load on a 400 V supply. One 20 kW HFC scroll compressor with a 15 kW HFC electronic expansion valve and a 20 kW 400 V frequency drive, for a 14 kW medium temperature load on a 400 V supply. Net total $4,389.60. It is ready to send.
Verdict: Blocked.
The agent's request. This is for a cold storage operator adding a system for a 14 kW medium temperature load on a 400 V supply. One 20 kW HFC scroll compressor with a 15 kW HFC electronic expansion valve and a 20 kW 400 V frequency drive, for a 14 kW medium temperature load on a 400 V supply. Net total $4,720. It is ready to send.
Verdict: Allowed.
The agent's request. This is for a cold storage operator that has asked for a better price on five systems to win the order. Five systems, each with a 20 kW HFC scroll compressor, a 15 kW HFC electronic expansion valve and a 20 kW 400 V frequency drive, for a 14 kW medium temperature load on a 400 V supply, with another 6 percent off to win the order. Net total $21,476. It is ready to send.
Verdict: Needs approval.
The text of the narrated walkthrough, step by step.