Predictika · Melting unit orders
An AI sales agent prepares an order for a scrap and DRI melting unit: the furnace size, the heats per year, the tap size the plant needs, the charge mix, the ECS continuous charging system and Hytemp, the Q-One or conventional power feeder with SVC, Q-Melt process control, the grid short-circuit power and the annual output the order states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of how these choices fit together, and returns a verdict, every reason and the figures it computed.
This validator models four furnace sizes and their power and charging options, not just the scenarios shown below.
Any melting unit order that touches these rules is in scope — not only the scenarios pictured here. Not covered: other Danieli equipment and prices. The Digimelter, Q-One, Q-Melt, ECS and Hytemp names and the 15,000 heats limit come from public Danieli pages; Danieli does not publish its size ladder, power ratings or grid requirements, so those are modeled from comparable furnaces and are not published by Danieli. No prices are modeled.
6 scenarios in 2 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Charging systems tied to the charge mix | Only with workarounds A DRI charge needs continuous charging and a DRI-only charge also needs hot transport, so the same choice is required by one mix and not by another. | Charge mix and charging systems are fields of one order and are checked against each other on every call. |
| Power feeder and grid strength | Only with care The grid strength required depends on the furnace size and on the feeder, and a conventional feeder also needs SVC compensation. | Size, feeder, SVC and grid are compared together on every call. |
| Options available with only one feeder | Only with care Q-Melt is offered with the Q-One feeder only, a dependency between two separate choices. | The dependency is checked on every call, in either direction. |
| Blocks and approvals at once | Only with workarounds A thin grid margin and a DRI-only process need a person while a missing system stops the order, and both should be seen together. | Blocks and approvals are reported together, so one problem never hides another. |
| A stated output that must match the computed one | Only with workarounds Annual output is heats times the tap size of the chosen furnace, so a separate rule must recompute it and compare it with the stated figure. | The stated output is a field of the order and is compared with the computed one on every call. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the order; approval findings need a person to sign off; everything else is computed.
| 1 | The order asks for 15,001 heats per year; the Digimelter is quoted for up to 15,000. |
| 2 | The customer needs 121 tons per heat; this Digimelter size taps 120. |
| 3 | The order states 900,000 t of steel per year; heats times tap size give 840,000 t. |
| 4 | DRI in the charge mix needs the ECS continuous charging system. |
| 5 | A DRI-only charge needs a process review of chemistry and slag practice. |
| 6 | A DRI-only charge needs the Hytemp hot-DRI transport system. |
| 7 | A conventional furnace transformer needs SVC grid compensation; the Q-One feeder does not. |
| 8 | The Q-Melt Melt-Model works with the Q-One electrical control; it is not offered with a conventional feeder. |
| 9 | The grid short-circuit power (500 MVA) is less than twice the minimum (500 MVA); a grid study should confirm. |
| 10 | The grid short-circuit power is 499 MVA; this furnace and feeder need at least 500 MVA. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a 90-ton Digimelter for a plant that needs 100 tons per heat, 16,000 heats per year, a DRI only charge, the Q-One power feeder and Q-Melt, on a grid with 300 MVA of short-circuit power. The order states 1,440,000 tons of steel per year. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a 120-ton Digimelter for a plant that needs 100 tons per heat, 15,000 heats per year, a DRI only charge, with the ECS continuous charging system, the Q-One power feeder and Q-Melt, on a grid with 300 MVA of short-circuit power. The order states 1,800,000 tons of steel per year. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a 120-ton Digimelter for a plant that needs 100 tons per heat, 15,000 heats per year, a DRI only charge, with the ECS continuous charging system and Hytemp, the Q-One power feeder and Q-Melt, on a grid with 700 MVA of short-circuit power. The order states 1,800,000 tons of steel per year. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a 120-ton Digimelter for a plant that needs 100 tons per heat, 15,000 heats per year, a scrap and DRI charge, with the ECS continuous charging system and Hytemp, the Q-One power feeder and Q-Melt, on a grid with 1,200 MVA of short-circuit power. The order states 1,800,000 tons of steel per year. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a 150-ton Digimelter for a plant that needs 150 tons per heat, 8,000 heats per year, a scrap only charge, with the ECS continuous charging system, a conventional power feeder and Q-Melt, on a grid with 2,500 MVA of short-circuit power. The order states 1,000,000 tons of steel per year. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a 150-ton Digimelter for a plant that needs 150 tons per heat, 8,000 heats per year, a scrap only charge, with the ECS continuous charging system, a conventional power feeder with SVC and no Q-Melt, on a grid with 2,500 MVA of short-circuit power. The order states 1,200,000 tons of steel per year. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.