Predictika · Welding technology
An AI sales agent configures a Titan XQ puls MIG/MAG welding machine for a fabrication shop: the model, the welding current the job needs at its duty cycle, the mains fuse and site supply, the wire feeder options, the torch cooling and the working conditions. Before the quote goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures in the EWM Titan XQ puls brochure and returns a verdict, every reason and the figures it computed.
This validator checks the configuration of one Titan XQ puls machine at a time, against the figures in the public EWM Titan XQ puls brochure (Update 2020), not just the scenarios shown below.
Any quote for these machines that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the brochure has none, so this page shows no price build-up), generator operation, mains voltage variants, the other EWM product lines, later brochure editions and the brochure's drawings. This model follows the 2020 brochure; models and figures may since have changed.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Welding current that depends on model and duty cycle together | Only with workarounds Each model gives a different current at 100, 80, 60 and 40 percent. A rules-based CPQ needs the grid loaded as a lookup table with a rule per model, and a quote field the sales agent actually fills in for the job current. | The grid is part of the model; the job current, duty cycle and model are compared together on every call, and an unlisted duty cycle is returned to a person. |
| A current the quote states that does not match the model | Only with care The figure written into the quote text is rarely a field a product rule can see, so a wrong rating can reach the customer unchecked. | The stated figure is compared with the model's rating on every call. |
| Options that only work together, or not at all on the compact machine | Only with workarounds Hose holder, rotatable feeder, wheel kit, mandrel nozzle, second feeder, lifting frame and spool heater each have a dependency or exclusion. Each needs its own rule and they must be kept in step across six models. | Every dependency and exclusion is checked together, in any order the choices arrive. |
| Mains fuse and site supply that depend on the model | Only with care Fuse and connected load are installation facts that rules-based CPQ seldom captures at quote time. | They are fields in the request, checked against the model on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The job needs 410 A at 80 percent duty cycle; this model gives 400 A at 40 degrees Celsius. |
| 2 | The job needs 380 A at 100 percent duty cycle; this model gives 370 A at 40 degrees Celsius. |
| 3 | The job needs 560 A at 60 percent duty cycle; this model gives 550 A at 40 degrees Celsius. |
| 4 | The data lists welding current at duty cycles of 100, 80, 60 and 40 percent; the plan uses 70 percent. |
| 5 | The quote states 450 A at this duty cycle; the model gives 400 A. |
| 6 | The mains supply is fused at 3 x 20 A slow-blow; this model needs 3 x 25 A. |
| 7 | The site supply is 18 kVA; this model has a maximum connected load of 19 kVA (rounded up). |
| 8 | The wire feeder takes standardised wire spools of 200 to 300 mm; the plan has 350 mm. |
| 9 | The wire feed speed is 30 m/min; the wire feed drive covers 0.5 to 25 m/min. |
| 10 | The working temperature is 45 degrees Celsius; the machine is rated for -25 to 40 degrees. |
| 11 | The torch is water cooled but the machine is the gas-cooled version, which has no cooling unit. |
| 12 | The hose package holder cannot be combined with the Titan XQ puls compact. |
| 13 | The lifting frame cannot be combined with the Titan XQ puls compact. |
| 14 | The WHS wire spool heater is not available for the Titan XQ puls C. |
| 15 | A second wire feeder on the Titan XQ puls compact needs the second wire feeder connection option, which is not in the plan. |
| 16 | The working distance is 35 m; with the optional miniDrive the compact machine reaches up to 30 m. |
| 17 | The brochure gives the Titan XQ 350 puls C 350 A at 100 percent duty cycle but the EWM product page gives 320 A; a person should confirm the rating for a job of 340 A. |
| 18 | The job needs 330 A at 100 percent duty cycle; this model gives 320 A at 40 degrees Celsius. |
| 19 | The hose package holder is to be used together with the rotatable wire feeder option, which is not in the plan. |
| 20 | A Drive XQ with a wheel kit on the rotatable wire feeder needs the turning mandrel extension nozzle, which is not in the plan. |
| 21 | The factory-installed rolls are Uni rolls for 1.0 to 1.2 mm steel wire; for this wire a person should confirm the roll set. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a Titan XQ 400 puls with a water-cooled machine and a water-cooled torch. The job needs 420 A at 80 percent duty cycle, with steel wire of 1.2 mm on 300 mm spools at 15 m/min, working at 20 degrees Celsius and 5 m from the machine. The shop supply is fused at 3 x 20 A slow-blow and is 15 kVA. Options: none. The quote text says the machine gives 420 A at this duty cycle. It is ready to go to the customer.
Verdict: Blocked.
The agent's request. Please quote a Titan XQ 500 puls with a water-cooled machine and a water-cooled torch. The job needs 420 A at 80 percent duty cycle, with steel wire of 1.2 mm on 300 mm spools at 15 m/min, working at 20 degrees Celsius and 5 m from the machine. The shop supply is fused at 3 x 32 A slow-blow and is 26 kVA. Options: none. The quote text says the machine gives 500 A at this duty cycle. It is ready to go to the customer.
Verdict: Allowed.
The agent's request. Please quote a Titan XQ 400 puls C with a water-cooled machine and a water-cooled torch. The job needs 300 A at 60 percent duty cycle, with steel wire of 1.2 mm on 300 mm spools at 15 m/min, working at 20 degrees Celsius and 40 m from the machine. The shop supply is fused at 3 x 20 A slow-blow and is 19 kVA. Options: a hose package holder, the rotatable wire feeder, a lifting frame, the WHS spool heater, a second wire feeder. It is ready to go to the customer.
Verdict: Blocked.
The agent's request. Please quote a Titan XQ 400 puls with a water-cooled machine and a water-cooled torch. The job needs 300 A at 60 percent duty cycle, with steel wire of 1.2 mm on 300 mm spools at 15 m/min, working at 20 degrees Celsius and 40 m from the machine. The shop supply is fused at 3 x 25 A slow-blow and is 19 kVA. Options: a hose package holder, the rotatable wire feeder, a lifting frame, the WHS spool heater, a second wire feeder. It is ready to go to the customer.
Verdict: Allowed.
The agent's request. Please quote a Titan XQ 600 puls with a gas-cooled machine and a water-cooled torch. The job needs 550 A at 60 percent duty cycle, with steel wire of 1.2 mm on 350 mm spools at 30 m/min, working at 20 degrees Celsius and 5 m from the machine. The shop supply is fused at 3 x 32 A slow-blow and is 36 kVA. Options: the rotatable wire feeder, a wheel kit. The quote text says the machine gives 600 A at this duty cycle. It is ready to go to the customer.
Verdict: Blocked.
The agent's request. Please quote a Titan XQ 600 puls with a water-cooled machine and a water-cooled torch. The job needs 550 A at 60 percent duty cycle, with aluminium wire of 1.2 mm on 300 mm spools at 20 m/min, working at 20 degrees Celsius and 5 m from the machine. The shop supply is fused at 3 x 32 A slow-blow and is 36 kVA. Options: the rotatable wire feeder, a wheel kit, the turning mandrel extension nozzle. The quote text says the machine gives 550 A at this duty cycle. It is ready to go to the customer.
Verdict: Needs approval.
The agent's request. Please quote a Titan XQ 600 puls with a water-cooled machine and a water-cooled torch. The job needs 550 A at 60 percent duty cycle, with steel wire of 1.2 mm on 300 mm spools at 20 m/min, working at 20 degrees Celsius and 5 m from the machine. The shop supply is fused at 3 x 32 A slow-blow and is 36 kVA. Options: the rotatable wire feeder, a wheel kit, the turning mandrel extension nozzle. The quote text says the machine gives 550 A at this duty cycle. It is ready to go to the customer.
Verdict: Allowed.