Predictika · Fire suppression and explosion protection quotes
An AI sales agent prepares a fire suppression and explosion protection quote for a fictional customer, with clean-agent rooms, explosion suppression and isolation, rupture discs and explosion vents in one request. Before it goes out, the agent sends it to Predictika, which checks it against a model of Fike's public product rules, compares the net total the agent states with its own, and returns a verdict with every reason.
This validator models 1,084 of the 1,190 Fike configuration rules we inventoried from public product information (91 percent). It handles any quote built from these product lines, not just the scenarios shown below.
Any Fike quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: real Fike prices and availability. Prices and thresholds are estimates unless Fike publishes them. About 9 percent of the inventoried rules are not modeled.
8 scenarios in 4 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Hundreds of product rules across eight product lines | Only with workarounds Each product line needs its own option rules and validation rules, and they interact (agent, container, nozzle, market, food contact). | Every product is data in a catalog; the same rules evaluate every combination. |
| Food and hygienic contact rules | Only with care A food flag changes which nozzle, agent, cover, pad and detector are allowed, so each is a conditional rule on a different object. | The food flag is evaluated with every other rule and every reason is named. |
| Design concentration and occupied rooms | Only with care Safe limits depend on the agent, the room temperature and whether people are present, which means calculated fields plus validation rules per agent. | Concentration at maximum temperature is derived on each call and compared with each limit. |
| Controllers and commissioning charges | Only with care The number of controllers follows detector inputs and actuators across several lines and then drives a price adder. | Counts and charges are derived across lines on every call and reconcile to the net total. |
| The net total the agent states | Only with workarounds Comparing a stated figure with a computed one needs a separate rule per layout, and price rules rarely run on stated figures. | The stated net total is a field in the request and is checked against the computed net total. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is built, so a problem raised late can hide an earlier one. | Every rule is evaluated at the end of input and all findings come back together. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off. These are findings recorded from the validator running its test cases on October 19, 2026.
| 1 | Bucket elevator legs are vented with EleGuard vents, not HI-CV round DN600 EN1092. |
| 2 | Metal dust with FlamQuench II DN600 91000520-S requires Fike consultation. |
| 3 | EleQuench 350x650 mm 34603900 is for organic dusts only. |
| 4 | Process temperature 70 C is outside the vent limit -20 to 60 C - use PFA seal / CV-I / CV-S-I / HT variant or consult Fike. |
| 5 | Ambient temperature 70 C is outside the EXV-ESS rect 920x920 mm ambient range -20 to 60 C. |
| 6 | Pred 0.7 bar exceeds the vent Pred max 0.6 bar. |
| 7 | Battery energy storage vent - engineered from off-gas analysis and large-scale testing. |
| 8 | Silicone gasket is not rated for 300 C. |
| 9 | BI indicator is not rated for process temperature 300 C. |
| 10 | FlamQuench II SQ 24x36in 91209000 operating limit is 260 C - process 300 C. |
| 11 | Insulated vents shall not be used with FlamQuench II SQ 24x36in 91209000 - Armaflex on the panel is permitted. |
| 12 | The flameless dust cover is rated to 150 C - process 300 C. |
| 13 | Pred 0.1 bar must be at least Pstat 0.075 bar plus twice the burst tolerance 0.015 bar. |
| 14 | Pstat 0.12 bar is outside the EleGuard rect 350x650 mm burst range 0.05 to 0.1 bar. |
| 15 | KG 200 bar m/s exceeds the EXV-GEP-I round DN500 limit 170 bar m/s. |
| 16 | Pmax 9 bar exceeds the EXV-GEP-I round DN500 limit 8 bar. |
| 17 | Gas engine exhaust in manned or marine areas needs the GEX flameless device. |
| 18 | EPACO PSU supports batteries up to 75 Ah - 88 Ah quoted. |
| 19 | EPACO is a legacy system - one-year warranty - EXP is the current controller. |
| 20 | Installed 44 Ah is below the 149.18 Ah battery calculation - ESTIMATE. |
| 21 | 15 RC8 relay cards exceed the 4 per EPACO system. |
| 22 | EPACO load 5.18 A exceeds the 5 A PSU limit. |
| 23 | Ambient 65 C is outside -18 to 60 C for CERex 29945022-C-S. |
| 24 | Installation distance for FAV DN150 must be calculated by Fike EP Applications - IsolCalc. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Quote for Northfield Plant: FM-200 in an occupied room at 11 percent and ECARO-25 in a UPS room, two food-processing suppression lines (spreader nozzle with food-grade agent, and a telescopic nozzle with standard sodium bicarbonate), an isolation valve, an SRL 3 in rupture disc operating at 85 psig and an indoor explosion vent with no duct. National account with a 4 percent extra discount. Net total $161,698.50. Ready to send.
Verdict: Blocked.
The agent's request. Quote for Northfield Plant: the same five product lines with the FM-200 room at the standard concentration, hygienic nozzles and food-grade agent on both lines, the rupture disc operating at 75 psig and the vent ducted 3 m outside. National account with a 4 percent extra discount. Net total $127,326.01. Ready to send.
Verdict: Allowed.
The agent's request. Quote for Lindqvist Datacenter: an SF 1230 clean-agent system in a 650 lb container with BSP nozzles for the 1,000 sq ft occupied room, EU market. Net total $29,594.00. Ready to send.
Verdict: Needs approval.
The agent's request. Quote for Lindqvist Datacenter: an FM-200 clean-agent system in CE-marked 83 L containers with BSP nozzles for the 1,000 sq ft occupied room, EU market. Net total $22,395.68. Ready to send.
Verdict: Allowed.
The agent's request. Quote for Calloway Gas Compression: one 3 in SRL stainless steel rupture disc, 100 psig burst at 100 F, gas service, primary duty, 120 psig MAWP, operating at 85 psig. Net total $1,105.00. Ready to send.
Verdict: Blocked.
The agent's request. Quote for Calloway Gas Compression: one 3 in SRL stainless steel rupture disc, 100 psig burst at 100 F, gas service, primary duty, 120 psig MAWP, operating at 75 psig. Net total $1,105.00. Ready to send.
Verdict: Allowed.
The agent's request. Quote for Ridgeway Grain Products: one rectangular 36 x 44 in explosion vent for a 10 m3 dust collector, Kst 150, Pmax 8 bar, indoor location, no duct. Net total $2,360.00. Ready to send.
Verdict: Blocked.
The agent's request. Quote for Ridgeway Grain Products: one rectangular 36 x 44 in explosion vent for a 10 m3 dust collector, Kst 150, Pmax 8 bar, indoor location, ducted 3 m to the outside. Net total $2,360.00. Ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.