Predictika · Plug and anchor fixing quotes
An AI sales agent prepares a quote for fischer DuoPower ETA universal plugs: which plug and screw, what it is fixed into, how far from the edge and from the next plug, how thick the member is, how long the screw is, what load it carries and where it will be used. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published load table and European Technical Assessment and returns a verdict, every reason and the figures it computed.
This validator models quotes for the three DuoPower ETA variants in ETA-22/0512, not just the scenarios shown below.
Any quote for these plugs that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (fischer publishes no price list for these plugs, so this validator produces no price build-up or line-item quote), other fischer plug families, and structural design calculations.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Edge distance and spacing that depend on each other | Only with workarounds The minimum edge distance is lower when the spacing is larger, and the listed combinations leave gaps between them; in a rules-based CPQ this becomes a grid of per-combination rules that someone keeps in step with the assessment. | The relationship is part of one model, so any edge distance and spacing is checked and values between the listed ones are sent for approval. |
| Permissible load that depends on plug, screw and base material | Only with care Every plug, screw and base material combination has its own tension and shear value, so each is another table to maintain and compare with the requirement. | The permissible load is looked up from the chosen combination and compared with the load on every call. |
| Options that exist only in some base materials | Only with workarounds The 8x40 is assessed in concrete only, masonry needs its own minimum distances and a minimum thickness, and perforated brick needs rotary drilling; each is a separate condition. | The conditions follow the base material, so any base material is checked with no extra rules. |
| Stated loads that must match the load table | Only with care A stated permissible load is a free-entry field; a rule can compare it with the table value, but someone has to write and maintain that comparison. | The stated figures travel with the quote and are compared with the computed figures on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The tension load per anchor is 0.65 kN, but the permissible tension load for this anchor in this base material is 0.6 kN. |
| 2 | The tension load per anchor is 0.3 kN, but the permissible tension load for this anchor in this base material is 0.12 kN. |
| 3 | The tension load per anchor is 0.9 kN, but the permissible tension load for this anchor in this base material is 0.79 kN. |
| 4 | The shear load per anchor is 6.5 kN, but the permissible shear load for this anchor in this base material is 5.98 kN. |
| 5 | The DuoPower ETA 8x40 with fischer PowerFast II comes with a galvanised screw only; a stainless steel screw is available with the special screw variants. |
| 6 | In solid and perforated brick the assessment covers the DuoPower ETA 10x50 with special screw only; the 8x40 is assessed in concrete only. |
| 7 | For external exposure or permanently damp interiors the assessment allows only the special screw in stainless steel (corrosion resistance class III). |
| 8 | The member is 120 mm thick, but this base material needs at least 150 mm. |
| 9 | The member is 100 mm thick, but this base material needs at least 115 mm. |
| 10 | An edge distance of 60 mm with a spacing of 100 mm is below the minimum for this anchor in concrete; the minimum spacing is 50 mm, and the minimum edge distance is 80 mm only when the spacing is at least 160 mm. |
| 11 | An edge distance of 120 mm with a spacing of 40 mm is below the minimum for this anchor in concrete; the minimum spacing is 50 mm, and the minimum edge distance is 80 mm only when the spacing is at least 160 mm. |
| 12 | In masonry the minimum edge distance is 80 mm; the edge distance given is 70 mm. |
| 13 | In masonry the minimum spacing for a single anchor to the next fixing is 250 mm; the spacing given is 200 mm. |
| 14 | In masonry the minimum spacing within an anchor group is 50 mm; the spacing given is 40 mm. |
| 15 | The assessment specifies hammer drilling in concrete and in solid brick, and rotary drilling in perforated brick. |
| 16 | The screw is 70 mm long, but this anchor with a fixture 20 mm thick needs a screw of at least 77 mm. |
| 17 | The assessment covers a fixture thickness of at least 1 mm. |
| 18 | The DuoPower ETA is assessed only for multiple fixings of non-structural systems, not for structural or single safety-relevant fixings. |
| 19 | The assessment covers static and quasi-static loading only. |
| 20 | Resistance to fire is not assessed for this plug (no performance assessed). |
| 21 | The substrate can fall to -30 deg C, but the assessment covers -20 deg C to +40 deg C. |
| 22 | The long-term substrate temperature is 30 deg C, but the permissible loads are valid up to +24 deg C. |
| 23 | The short-term substrate temperature is 45 deg C, but the permissible loads are valid up to +40 deg C short term. |
| 24 | The quote states a permissible tension load of 0.9 kN per anchor, but the load table gives 0.79 kN. |
| 25 | The quote states a permissible shear load of 6.5 kN per anchor, but the load table gives 5.98 kN. |
| 26 | The load table covers concrete of strength class C16/20 and above; for C12/15 the permissible loads, edge distances and spacings come from the assessment tables and need an engineer to confirm. |
| 27 | For other comparable base materials the assessment allows the resistance to be determined only by job site tests (TR 051); an engineer must confirm the test results. |
| 28 | The load is a combination of tension and shear; the load table covers each load on its own, and the combination is checked under the assessment by an engineer. |
| 29 | An edge distance of 90 mm with a spacing of 100 mm lies between the combinations listed for this anchor in concrete; the assessment allows linear interpolation, which an engineer must confirm. |
| 30 | The member is 100 mm thick, but this base material needs at least 150 mm. |
| 31 | An edge distance of 40 mm with a spacing of 40 mm is below the minimum for this anchor in concrete; the minimum spacing is 50 mm, and the minimum edge distance is 50 mm only when the spacing is at least 100 mm. |
| 32 | The tension load per anchor is 0.5 kN, but the permissible tension load for this anchor in this base material is 0.12 kN. |
| 33 | The quote states a permissible tension load of 0.5 kN per anchor, but the load table gives 0.12 kN. |
| 34 | In masonry the minimum edge distance is 80 mm; the distance to the second edge is 70 mm. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a DuoPower ETA 8x40 with PowerFast II fixing in concrete C16/20, zinc coated screw, indoors. The member is 200 mm thick, the edge distance is 40 mm, the spacing is 100 mm, the fixture is 18 mm thick and the screw is 67 mm long. The load is 0.3 kN in tension per anchor. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a DuoPower ETA 10x50 with special screw fixing in concrete C16/20, zinc coated screw, indoors. The member is 200 mm thick, the edge distance is 120 mm, the spacing is 100 mm, the fixture is 18 mm thick and the screw is 78 mm long. The load is 0.3 kN in tension per anchor. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a DuoPower ETA 8x40 with special screw fixing in sand-lime brick KS 12, zinc coated screw, indoors. The member is 115 mm thick, the edge distance is 70 mm, the spacing is 60 mm, the fixture is 18 mm thick and the screw is 67 mm long. The load is 0.65 kN in tension per anchor. The quote states no permissible load. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a DuoPower ETA 10x50 with special screw fixing in sand-lime brick KS 12, zinc coated screw, indoors. The member is 115 mm thick, the edge distance is 110 mm and 165 mm to the second edge, the spacing is 60 mm, the fixture is 18 mm thick and the screw is 78 mm long. The load is 0.65 kN in tension per anchor. The quote states permissible loads of 0.7 kN in tension and 0.7 kN in shear per anchor. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a DuoPower ETA 10x50 with special screw fixing in concrete C16/20, zinc coated screw, outdoors. The member is 200 mm thick, the edge distance is 90 mm, the spacing is 80 mm, the fixture is 25 mm thick and the screw is 85 mm long. The load is 0.6 kN in tension per anchor. The quote states permissible loads of 0.79 kN in tension and 5.98 kN in shear per anchor. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a DuoPower ETA 10x50 with special screw fixing in concrete C16/20, stainless steel screw, outdoors. The member is 200 mm thick, the edge distance is 90 mm, the spacing is 80 mm, the fixture is 25 mm thick and the screw is 85 mm long. The load is 0.6 kN in tension per anchor. The quote states permissible loads of 0.79 kN in tension and 5.98 kN in shear per anchor. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a DuoPower ETA 10x50 with special screw fixing in concrete C16/20, stainless steel screw, outdoors. The member is 200 mm thick, the edge distance is 100 mm, the spacing is 80 mm, the fixture is 25 mm thick and the screw is 85 mm long. The load is 0.6 kN in tension per anchor. The quote states permissible loads of 0.79 kN in tension and 5.98 kN in shear per anchor. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.