An AI sales agent prepares a quote for Flowserve Mark 100 control valves: the valve size and pressure class, the trim and its flow direction, the flow capacity the customer needs, the seal and the process temperature, the shutoff class, the actuator, and the face-to-face dimension the quote states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the tables in the Flowserve Mark 100 technical bulletin and returns a verdict, every reason and the figures it computed.

Scope: Mark 100 control valves (sizes 6 to 16 inch, with larger sizes sent to a person): trim, flow capacity, seal temperature and shutoff, actuator and face-to-face dimension from the technical bulletin. See everything this validator covers

This validator models a quote for one Mark 100 valve configuration at a time, based on the tables in the public Flowserve Mark 100 technical bulletin (VATB003320-00, March 2026), not just the scenarios shown below.

  • Size, class and trim — valve sizes 6 to 16 inch in classes 150, 300 and 600, the three standard trim sizes listed for each valve size with their stroke, and the flanged face-to-face dimension for each size and class. A stated face-to-face dimension must equal the bulletin's.
  • Flow capacity — the capacity the customer needs against the capacity the bulletin lists for the chosen size, trim and flow direction (under or over the plug), for equal percent and linear trim. Quick open and the severe service trims (MegaStream, cavity control, channel stream and Diamondback) have no listed capacity in the bulletin and go to a person for approval. The bulletin does not state the unit of its capacity table, so the validator compares the numbers as they are given.
  • Seals and shutoff — the temperature range of each seal (Buna, Viton, EPDM, filled PTFE, spring energized and metal multi) against the process temperature, and the ANSI shutoff class each seal is listed for. Class VI is listed only with the optional soft seat, and the metal multi seal with a severe service trim is limited to Class III.
  • Actuators — the aluminum, carbon steel VLC and carbon steel VL-ES actuator sizes the bulletin offers with each valve size, and the rule that carbon steel sizes 300 and 400 are available only in the VL-ES series.

Any Mark 100 quote that touches these rules is in scope — not only the scenarios pictured here. Valves of 18 inch and larger are sent to a person for approval, because the bulletin's specification table lists sizes 6 to 16 while later tables go up to 30. Not covered: prices (Flowserve does not publish them), weights, carbon seals (the bulletin's temperature limit for them is unreadable in the PDF), Kalrez seals, capacity figures for 18 inch and larger valves, the face-to-face dimension of buttweld ends (not in the bulletin), other Flowserve valve families, positioners and accessories.

The AI sales agentBuilds the valve quote from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

8 scenarios in 4 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
Trim sizes and strokes that exist only for certain valve sizesOnly with workarounds
Each valve size has its own three trim sizes, strokes and capacities. A rules-based CPQ needs a compatibility table or one rule per row, and every bulletin revision means editing them.
The size and trim arrive in one request and are matched to the published row on every call.
Capacity that depends on size, trim and flow directionOnly with care
The capacity to compare with is a lookup on three choices, and quick open and severe service trims have none, so a rule must handle the gap.
The listed capacity is looked up on every call, and a trim with no listed capacity is sent to a person.
Seal temperature range and shutoff class togetherOnly with care
Each seal has its own temperature range and shutoff class, and one seal changes class with the trim. These are product rules that must be kept in step.
Seal, temperature, trim and shutoff class are in one request and checked together.
Face-to-face dimension the quote statesOnly with care
The stated figure comes from the size and class, so a rule has to look it up and compare.
The stated dimension is a field in the request, compared with the bulletin's on every call.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1The quote has 0 valves; at least 1 is needed.
2A valve size of 9 inches is not listed; the bulletin gives the Mark 100 in 6, 8, 10, 12, 14, 16, 18, 20, 24 and 30 inch.
3ANSI class 900 is not offered; the bulletin lists classes 150, 300 and 600.
4A trim size of 800 (hundredths of an inch) is not listed for the 6-inch Mark 100 valve in the standard trim table.
5The quote needs a flow capacity of 900; the standard trim table lists 852 for this size, trim and flow direction.
6The quote needs a flow capacity of 800; the standard trim table lists 751 for this size, trim and flow direction.
7The quote needs a flow capacity of 860; the standard trim table lists 852 for this size, trim and flow direction.
8The bulletin lists standard trim capacities only for linear and equal percent trim; a person should confirm a flow capacity of 600 with the sizing program.
9The process temperature of -20 degrees Fahrenheit is outside the -15 to 400 degrees Fahrenheit range listed for the selected pressure balanced seal.
10The process temperature of 401 degrees Fahrenheit is outside the -15 to 400 degrees Fahrenheit range listed for the selected pressure balanced seal.
11The process temperature of 300 degrees Fahrenheit is outside the -40 to 250 degrees Fahrenheit range listed for the selected pressure balanced seal.
12The selected seal is listed with ANSI Class IV shutoff; the quote asks for Class V.
13The metal multi seal is limited to ANSI Class III shutoff with severe service trims; the quote asks for Class IV or V.
14ANSI Class VI shutoff is listed only with the optional soft seat; the quote does not include it.
15An actuator of size 300 is not offered with the 10-inch valve in the actuator table.
16An actuator size of 250 is not listed for the selected actuator type.
17Carbon steel actuator sizes 300 and 400 are available only in the VL-ES series, not the VLC.
18An actuator of size 400 is not offered with the 10-inch valve in the actuator table.
19The quote states a face-to-face dimension of 720 mm; the flanged dimension in the bulletin is 708 mm.
20The specification table lists sizes 6 through 16 inch while later tables go up to 30 inch; a person should confirm that a valve of 18 inches is offered and its trim, actuator and dimensions.
21The specification table lists sizes 6 through 16 inch while later tables go up to 30 inch; a person should confirm that a valve of 30 inches is offered and its trim, actuator and dimensions.
22A trim size of 900 (hundredths of an inch) is not listed for the 10-inch Mark 100 valve in the standard trim table.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Cold service, seal and actuator: Cold service with a filled PTFE seal and a large actuator

The agent's request. Please quote 8 Mark 100 control valves of 8 inch, class 600, with equal percent trim of 7.75 inches, flowing under the plug. The customer needs a flow capacity of 700. The seal is filled PTFE, the process temperature is -45 degrees Fahrenheit and the shutoff class is ANSI Class V. The actuator is aluminum, size 300. The quote states a flanged face-to-face dimension of 610 mm. It is ready to send.

Verdict: Blocked.

  • Shutoff class above what the seal gives. The selected seal is listed with ANSI Class IV shutoff; the quote asks for Class V.
  • Actuator not offered for this valve size. An actuator of size 300 is not offered with the 8-inch valve in the actuator table.

2. Cold service, seal and actuator: The agent resubmits after fixing the errors

The agent's request. Please quote 8 Mark 100 control valves of 8 inch, class 600, with equal percent trim of 7.75 inches, flowing under the plug. The customer needs a flow capacity of 700. The seal is Viton, the process temperature is -45 degrees Fahrenheit and the shutoff class is ANSI Class V. The actuator is aluminum, size 100. The quote states a flanged face-to-face dimension of 610 mm. It is ready to send.

Verdict: Blocked.

  • Process temperature outside the seal range. The process temperature of -45 degrees Fahrenheit is outside the -15 to 400 degrees Fahrenheit range listed for the selected pressure balanced seal.

3. Cold service, seal and actuator: The agent resubmits after fixing the errors

The agent's request. Please quote 8 Mark 100 control valves of 8 inch, class 600, with equal percent trim of 7.75 inches, flowing under the plug. The customer needs a flow capacity of 700. The seal is EPDM, the process temperature is -45 degrees Fahrenheit and the shutoff class is ANSI Class V. The actuator is aluminum, size 100. The quote states a flanged face-to-face dimension of 610 mm. It is ready to send.

Verdict: Allowed.

  • Quote summary. 8 valves, size 8 inch, class 600, stroke 102 mm, flanged face to face 610 mm, standard actuator size 100.

4. Flow capacity and face to face: Twelve-inch valves with too much flow and a wrong dimension

The agent's request. Please quote 6 Mark 100 control valves of 12 inch, class 300, with equal percent trim of 11.25 inches, flowing under the plug. The customer needs a flow capacity of 1,800. The seal is Viton, the process temperature is 200 degrees Fahrenheit and the shutoff class is ANSI Class V. The actuator is aluminum, size 100. The quote states a flanged face-to-face dimension of 780 mm. It is ready to send.

Verdict: Blocked.

  • Flow capacity above the listed trim capacity. The quote needs a flow capacity of 1,800; the standard trim table lists 1,705 for this size, trim and flow direction.
  • Stated face-to-face dimension does not match. The quote states a face-to-face dimension of 780 mm; the flanged dimension in the bulletin is 775 mm.

5. Flow capacity and face to face: The agent resubmits after fixing the errors

The agent's request. Please quote 6 Mark 100 control valves of 14 inch, class 300, with equal percent trim of 13.5 inches, flowing under the plug. The customer needs a flow capacity of 1,800. The seal is Viton, the process temperature is 200 degrees Fahrenheit and the shutoff class is ANSI Class V. The actuator is aluminum, size 100. The quote states a flanged face-to-face dimension of 927 mm. It is ready to send.

Verdict: Allowed.

  • Quote summary. 6 valves, size 14 inch, class 300, stroke 178 mm, flanged face to face 927 mm, standard actuator size 100.

6. Carbon steel actuator series: Fourteen-inch class 150 valves with a VLC carbon steel actuator

The agent's request. Please quote 3 Mark 100 control valves of 14 inch, class 150, with equal percent trim of 11 inches, flowing under the plug. The customer needs a flow capacity of 1,400. The seal is Viton, the process temperature is 250 degrees Fahrenheit and the shutoff class is ANSI Class V. The actuator is carbon steel VLC, size 400. The quote states a flanged face-to-face dimension of 900 mm. It is ready to send.

Verdict: Blocked.

  • Larger carbon steel actuators are VL-ES only. Carbon steel actuator sizes 300 and 400 are available only in the VL-ES series, not the VLC.
  • Stated face-to-face dimension does not match. The quote states a face-to-face dimension of 900 mm; the flanged dimension in the bulletin is 889 mm.

7. Carbon steel actuator series: The agent resubmits after fixing the errors

The agent's request. Please quote 3 Mark 100 control valves of 14 inch, class 150, with equal percent trim of 11 inches, flowing under the plug. The customer needs a flow capacity of 1,400. The seal is Viton, the process temperature is 250 degrees Fahrenheit and the shutoff class is ANSI Class V. The actuator is carbon steel VL-ES, size 400. The quote states a flanged face-to-face dimension of 889 mm. It is ready to send.

Verdict: Allowed.

  • Quote summary. 3 valves, size 14 inch, class 150, stroke 152 mm, flanged face to face 889 mm, standard actuator size 100.

8. Trim with no listed capacity: Low-noise trim on ten-inch valves

The agent's request. Please quote 5 Mark 100 control valves of 10 inch, class 300, with MegaStream trim of 8 inches, flowing under the plug. The customer needs a flow capacity of 700. The seal is Viton, the process temperature is 200 degrees Fahrenheit and the shutoff class is ANSI Class V. The actuator is aluminum, size 100. The quote states a flanged face-to-face dimension of 708 mm. It is ready to send.

Verdict: Needs approval.

  • Flow capacity not published for this trim. The bulletin lists standard trim capacities only for linear and equal percent trim; a person should confirm a flow capacity of 700 with the sizing program.
  • Quote summary. 5 valves, size 10 inch, class 300, stroke 127 mm, flanged face to face 708 mm, standard actuator size 100.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares a quote for Flowserve Mark 100 control valves: the valve size and pressure class, the trim and its flow direction, the flow capacity the customer needs, and more. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the tables in the Flowserve Mark 100 technical bulletin and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote 8 Mark 100 control valves of 8 inch, class 600, with equal percent trim of 7.75 inches, flowing under the plug. The customer needs a flow capacity of 700. The rest of the request is on screen.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with two findings, all in one answer. The selected seal is listed with ANSI Class IV shutoff; the quote asks for Class V. An actuator of size 300 is not offered with the 8-inch valve in the actuator table.
  6. The validator returned two blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for seal temperature range and shutoff class together, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the seal to viton and the actuator size to 100.
  10. It calls the validator again.
  11. Still blocked, with one finding, all in one answer. The process temperature of -45 degrees Fahrenheit is outside the -15 to 400 degrees Fahrenheit range listed for the selected pressure balanced seal.
  12. Two findings cleared, but the change brings a different blocking finding: process temperature outside the seal range.
  13. The agent resubmits once more.
  14. The revised request. It changes the seal to EPDM.
  15. It calls the validator once more.
  16. This time the validator clears it.
  17. The earlier finding is cleared.
  18. Two problems caught in one call, fixed in two passes, and a clean quote. That is the value of Predictika's validator: catching mistakes before they reach the customer.