Predictika · Industrial pump orders

An AI sales agent's pump order, checked before it goes out

An AI sales agent prepares an order for a plant or building-services engineer who needs a Grundfos CR or CRN vertical multistage pump: the pump size and number of stages, the motor, the flange connection, the duty pressures and the liquid temperature. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the pressure, motor and temperature limits in Grundfos's public data booklet and returns a verdict, every reason and the figures it computed.

Scope: Grundfos CR and CRN vertical multistage pumps (50 Hz, IEC): pump type by size and stages, standard motor, flange connection, operating and inlet pressure, liquid temperature. See everything this validator covers

This validator models orders for Grundfos CR and CRN pumps against the tables in Grundfos's public CR, CRI, CRN data booklet (50 Hz, read October 6, 2026), not just the scenarios shown below.

  • Pump type — CR pumps in sizes 1, 3, 5, 10, 15, 20, 32, 45, 64, 95, 125, 155, 185, 215 and 255, and CRN pumps in sizes 32 to 255. Each size is offered only with the stage counts (and reduced-diameter impeller variants) the booklet lists.
  • Motor — the booklet gives one standard motor power for each pump type; any other motor power is reported.
  • Flange connection — oval flange (BSP) or DIN flange; the oval flange is not offered on every type.
  • Pressure — the outlet pressure (inlet pressure plus the pump differential pressure) is compared with the maximum operating pressure for the pump type and connection, and the inlet pressure with the maximum permissible inlet pressure. For CRN sizes 32, 45 and 64 a high-pressure version is listed on request, so an outlet pressure between the standard maximum and that limit needs approval.
  • Liquid temperature — the standard range, the wider range Grundfos lists on request (to 180 °C, oils to 240 °C, down to −40 °C), and temperatures beyond that.

Any Grundfos CR or CRN order that touches these tables is in scope — not only the scenarios pictured here. Not covered: prices (the booklet lists none, so there is no price build-up or line-item quote), CRI pumps, CRN sizes below 32, the CR 1s variant, shaft-seal pressure and temperature limits at high pressure, liquid and material compatibility, 60 Hz pumps, motor voltage and make, and options beyond the booklet's tables. Pumps are selected for a duty point, so a check against these tables is a first filter, not a final selection.

The AI sales agentBuilds the pump order from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
A limit that depends on several choices at onceOnly with workarounds
The pressure limit varies with the pump size, the number of stages and the flange, so each combination needs its own rule or lookup, and a combination left out is never checked.
The limit for the exact combination is looked up and compared on every call.
A figure computed from two inputsOnly with care
The outlet pressure is the inlet pressure plus the differential pressure; it has to be calculated before any rule can compare it with a limit.
The outlet pressure is computed and checked in the same pass as everything else.
A standard component fixed by the pump typeOnly with care
The standard motor depends on the size, stages and impeller variant; a rule or table per type has to be kept in step with the booklet.
The motor ordered is compared with the standard motor for the exact pump type.
Not offered versus available on requestOnly with workarounds
Rules usually allow or block; a CRN outlet pressure above the standard maximum but within the high-pressure limit needs a person, which means a separate approval step.
The order is reported as needing approval, with the limit that applies, instead of being blocked or passed.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1There is no CR pump of size 7; this validator covers sizes 1, 3, 5, 10, 15, 20, 32, 45, 64, 95, 125, 155, 185, 215 and 255.
2This validator covers CRN pumps of sizes 32 to 255 only; the order is for a CRN of size 20.
3A CR pump of size 5 with 17 stages and 0 reduced-diameter impellers is not in the standard Grundfos range.
4The order specifies a motor of 2.2 kW; the standard motor for this pump type is 1.5 kW.
5The oval flange (BSP) connection is not offered on this pump type; the DIN flange is.
6The outlet pressure is 31 bar (inlet pressure plus pump differential pressure); the maximum operating pressure for this pump type and connection is 30 bar.
7The outlet pressure of 31 bar is above the standard maximum of 30 bar; a high-pressure version of this CRN pump is available on request up to 50 bar.
8The outlet pressure is 51 bar (inlet pressure plus pump differential pressure); the maximum operating pressure for this pump type and connection is 30 bar.
9The outlet pressure is 17 bar (inlet pressure plus pump differential pressure); the maximum operating pressure for this pump type and connection is 16 bar.
10The inlet pressure is 11 bar; the maximum permissible inlet pressure for this pump type is 10 bar.
11The outlet pressure is 11 bar (inlet pressure plus pump differential pressure); the maximum operating pressure for this pump type and connection is 10 bar.
12A liquid temperature of 130 C is outside the standard range for this pump of -20 C to 120 C; Grundfos supplies pumps for -40 to 180 C (oils to 240 C) on request.
13A liquid temperature of 200 C is above what Grundfos offers (180 C, or 240 C for oils).
14A liquid temperature of 200 C is outside the standard range for this pump of -20 C to 120 C; Grundfos supplies pumps for -40 to 180 C (oils to 240 C) on request.
15A liquid temperature of 250 C is above what Grundfos offers (180 C, or 240 C for oils).
16A liquid temperature of -25 C is outside the standard range for this pump of -20 C to 120 C; Grundfos supplies pumps for -40 to 180 C (oils to 240 C) on request.
17A liquid temperature of -45 C is below the -40 C that Grundfos offers.
18A liquid temperature of -35 C is outside the standard range for this pump of -30 C to 120 C; Grundfos supplies pumps for -40 to 180 C (oils to 240 C) on request.
19A CR pump of size 125 with 9 stages and 0 reduced-diameter impellers is not in the standard Grundfos range.
20The outlet pressure is 38 bar (inlet pressure plus pump differential pressure); the maximum operating pressure for this pump type and connection is 30 bar.
21The outlet pressure of 38 bar is above the standard maximum of 30 bar; a high-pressure version of this CRN pump is available on request up to 41 bar.
22The order specifies a motor of 11 kW; the standard motor for this pump type is 15 kW.
23The inlet pressure is 12 bar; the maximum permissible inlet pressure for this pump type is 10 bar.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. CR 32-8 pump for a 31 bar outlet: CR 32-8 with an oval flange and an 11 kW motor

The agent's request. Please quote a CR 32-8 pump with an 11 kW motor and oval flange (BSP), for an inlet pressure of 8 bar and a differential pressure of 23 bar. It is ready to send.

Verdict: Blocked.

  • Motor does not match the pump. The order specifies a motor of 11 kW; the standard motor for this pump type is 15 kW.
  • Oval flange not offered. The oval flange (BSP) connection is not offered on this pump type; the DIN flange is.

2. CR 32-8 pump for a 31 bar outlet: The agent resubmits after fixing the errors

The agent's request. Please quote a CR 32-8 pump with a 15 kW motor and DIN flange, for an inlet pressure of 8 bar and a differential pressure of 23 bar. It is ready to send.

Verdict: Blocked.

  • Outlet pressure too high. The outlet pressure is 31 bar (inlet pressure plus pump differential pressure); the maximum operating pressure for this pump type and connection is 30 bar.

3. CR 32-8 pump for a 31 bar outlet: The agent resubmits after fixing the errors

The agent's request. Please quote a CR 32-8 pump with a 15 kW motor and DIN flange, for an inlet pressure of 8 bar and a differential pressure of 22 bar. It is ready to send.

Verdict: Allowed.

  • Order summary. Size 32 pump with 8 stages, standard motor 15 kW, outlet pressure 30 bar.

4. Pump for an 18 bar inlet and a 20 bar differential: CR 125-9 on a DIN flange with a 110 kW motor

The agent's request. Please quote a CR 125-9 pump with a 110 kW motor and DIN flange, for an inlet pressure of 18 bar and a differential pressure of 20 bar. It is ready to send.

Verdict: Blocked.

  • Not a standard pump type. A CR pump of size 125 with 9 stages and 0 reduced-diameter impellers is not in the standard Grundfos range.

5. Pump for an 18 bar inlet and a 20 bar differential: The agent resubmits after fixing the errors

The agent's request. Please quote a CRN 125-9 pump with a 110 kW motor and DIN flange, for an inlet pressure of 18 bar and a differential pressure of 20 bar. It is ready to send.

Verdict: Allowed.

  • Order summary. Size 125 pump with 9 stages, standard motor 110 kW, outlet pressure 38 bar.

6. Pump for a 38 bar outlet: CR 64-6 on a DIN flange for an outlet of 38 bar

The agent's request. Please quote a CR 64-6 pump with a 37 kW motor and DIN flange, for an inlet pressure of 10 bar and a differential pressure of 28 bar. It is ready to send.

Verdict: Blocked.

  • Outlet pressure too high. The outlet pressure is 38 bar (inlet pressure plus pump differential pressure); the maximum operating pressure for this pump type and connection is 30 bar.

7. Pump for a 38 bar outlet: The agent resubmits after fixing the errors

The agent's request. Please quote a CRN 64-6 pump with a 37 kW motor and DIN flange, for an inlet pressure of 10 bar and a differential pressure of 28 bar. It is ready to send.

Verdict: Needs approval.

  • High-pressure version on request. The outlet pressure of 38 bar is above the standard maximum of 30 bar; a high-pressure version of this CRN pump is available on request up to 41 bar.
  • Order summary. Size 64 pump with 6 stages, standard motor 37 kW, outlet pressure 38 bar.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares an order for a plant or building-services engineer who needs a Grundfos CR or CRN vertical multistage pump: the pump size and number of stages, the motor, the flange connection, and more. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the pressure, motor and temperature limits in Grundfos's public data booklet and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote a CR 32-8 pump with an 11 kW motor and oval flange (BSP), for an inlet pressure of 8 bar and a differential pressure of 23 bar. It is ready to send.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with two findings, all in one answer. The order specifies a motor of 11 kW; the standard motor for this pump type is 15 kW. The oval flange (BSP) connection is not offered on this pump type; the DIN flange is.
  6. The validator returned two blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for a standard component fixed by the pump type, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the motor to 15 kW and the connection to DIN flange.
  10. It calls the validator again.
  11. Still blocked, with one finding, all in one answer. The outlet pressure is 31 bar (inlet pressure plus pump differential pressure); the maximum operating pressure for this pump type and connection is 30 bar.
  12. Two findings cleared, but the change brings a different blocking finding: outlet pressure too high.
  13. The agent resubmits once more.
  14. The revised request. It changes the differential pressure to 22 bar.
  15. It calls the validator once more.
  16. This time the validator clears it.
  17. The earlier finding is cleared.