Predictika · Ventilator configuration and accessory orders
An AI sales agent prepares an order for HAMILTON-C6 ventilators with the patient group, software options, breathing circuits, sensors, communication board, humidifier, nasal cannula, mount and power cord. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the compatibility rules in the HAMILTON-C6 operator's manual and returns a verdict, every reason and the figures it computed.
This validator models HAMILTON-C6 ventilator orders, not just the scenarios shown below.
Any HAMILTON-C6 order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Hamilton Medical publishes no price list, so this validator produces no price build-up), other Hamilton Medical ventilators, software versions, service plans and regional approval status.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Parts that exist for only one patient group | Only with care A product rule per circuit, sensor, adapter and cannula. It works, but every new part is another set of rules to maintain. | The patient group and every part are in one request and each pairing is checked together. |
| Options that depend on the patient group or destination | Only with workarounds Neonatal, IntelliSync+, INTELLiVENT-ASV and the USA each depend on a choice on a different line, so they need cross-line rules that interact. | Every choice is in one request, so the conflict is found whichever order the choices arrive in. |
| A cannula limit against a planned flow | Only with care The flow limit depends on which cannula is chosen and on the patient group; each pairing needs its own comparison. | The cannula limit is looked up and compared with the planned flow on every call. |
| Circuit counts that must cover planned patients and match the stated figure | Only with care A stated figure is a free-entry field; a rule can compare it with a computed total, but someone has to write and maintain that comparison. | The stated figure travels with the order and is compared with the computed figure on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The ventilator is ordered for neonatal patients, but the Neonatal patient group option is not on the quote; the HAMILTON-C6 includes only Adult/Ped as standard. |
| 2 | The nCPAP-PS mode is a neonatal option and the Neonatal patient group option is not on the quote. |
| 3 | The breathing circuit set on the quote is made for the other patient group (adult/pediatric versus neonatal) than the one the ventilator is ordered for. |
| 4 | The flow sensor on the quote is made for the other patient group than the one the ventilator is ordered for; a mismatched flow sensor makes calibration fail. |
| 5 | The CO2 airway adapter on the quote is made for the other patient group than the one the ventilator is ordered for. |
| 6 | CO2 monitoring needs a CO2 sensor and an airway adapter together; the quote has only one of them. |
| 7 | The CO2 airway adapter on the quote does not fit the CO2 sensor; mainstream and sidestream parts are not interchangeable. |
| 8 | CO2 and SpO2 monitoring need the extended communication board; the quote has none. |
| 9 | Aerogen nebulization needs the extended communication board with an Aerogen port (CO2, SpO2, Aerogen); the board on the quote does not have one. |
| 10 | INTELLiVENT-ASV is not available for the neonatal patient group. |
| 11 | INTELLiVENT-ASV is not available in the USA and the order ships there. |
| 12 | IntelliSync+ is available for adult and pediatric patients only, not for the neonatal patient group. |
| 13 | HiFlowO2 therapy needs an operating humidifier and the quote has no HAMILTON-H900 humidifier. |
| 14 | The HAMILTON-H900 humidifier is on the quote without the integration kit for the HAMILTON-C6; a person should confirm the customer already has one. |
| 15 | The planned HiFlowO2 flow is 35 l/min; for neonatal patients the flow can be set to at most 30 l/min. |
| 16 | The planned HiFlowO2 flow is 90 l/min, but the nasal cannula on the quote allows at most 80 l/min. |
| 17 | The In2Flow nasal cannula on the quote is an adult cannula and the ventilator is ordered for neonatal patients. |
| 18 | A high-flow nasal cannula is on the quote without the HiFlowO2 option; a person should confirm what it is for. |
| 19 | The quote has 3 trolley accessories, but the ventilator is ordered with the shelf mount instead of the trolley. |
| 20 | The power cord on the quote has the wrong plug for the country the order ships to. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 2 HAMILTON-C6 ventilators for adult/pediatric patients, shipping to USA, with 4 boxes of adult/pediatric circuit set BC8022 (15 per box) for 50 planned patients, flow sensor AP188 (adult/pediatric), mainstream CO2 adapter for adult/pediatric, trolley mount with 3 trolley accessories, the US power cord, and INTELLiVENT-ASV, IntelliSync+, HiFlowO2 at 80 l/min, and the In2Flow S nasal cannula. The quote states 75 circuit sets in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 HAMILTON-C6 ventilators for adult/pediatric patients, shipping to USA, with 4 boxes of adult/pediatric circuit set BC8022 (15 per box) for 50 planned patients, flow sensor AP188 (adult/pediatric), mainstream CO2 adapter for adult/pediatric, trolley mount with 3 trolley accessories, the US power cord, and IntelliSync+, HiFlowO2 at 80 l/min, with a HAMILTON-H900 humidifier and its integration kit, and the In2Flow L nasal cannula. The quote states 60 circuit sets in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 HAMILTON-C6 ventilator for neonatal patients, shipping to Switzerland, with 3 boxes of adult/pediatric circuit set BC8022 (15 per box) for 40 planned patients, flow sensor Neo160 (neonatal), mainstream CO2 adapter for neonatal, trolley mount with 2 trolley accessories, the US power cord, and IntelliSync+, nCPAP-PS, HiFlowO2 at 12 l/min, with a HAMILTON-H900 humidifier and its integration kit, and the Nuflow M nasal cannula. The quote states 60 circuit sets in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 HAMILTON-C6 ventilator for neonatal patients, shipping to Switzerland, with 3 boxes of neonatal circuit set BC8010 (15 per box) for 40 planned patients, flow sensor Neo160 (neonatal), mainstream CO2 adapter for neonatal, trolley mount with 2 trolley accessories, the US power cord, and the Neonatal patient group option, IntelliSync+, nCPAP-PS, HiFlowO2 at 12 l/min, with a HAMILTON-H900 humidifier and its integration kit, and the Nuflow M nasal cannula. The quote states 45 circuit sets in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 HAMILTON-C6 ventilator for neonatal patients, shipping to Switzerland, with 3 boxes of neonatal circuit set BC8010 (15 per box) for 40 planned patients, flow sensor Neo160 (neonatal), mainstream CO2 adapter for neonatal, trolley mount with 2 trolley accessories, the CH power cord, and the Neonatal patient group option, nCPAP-PS, HiFlowO2 at 12 l/min, with a HAMILTON-H900 humidifier and its integration kit, and the Nuflow M nasal cannula. The quote states 45 circuit sets in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 2 HAMILTON-C6 ventilators for adult/pediatric patients, shipping to USA, with 4 boxes of adult/pediatric circuit set BC8022 (15 per box) for 80 planned patients, flow sensor AP188 (adult/pediatric), sidestream CO2 adapter for adult/pediatric, shelf mount with 3 trolley accessories, the US power cord, and IntelliSync+, HiFlowO2 at 60 l/min, with a HAMILTON-H900 humidifier and its integration kit, and the In2Flow M nasal cannula. The quote states 80 circuit sets in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 HAMILTON-C6 ventilators for adult/pediatric patients, shipping to USA, with 6 boxes of adult/pediatric circuit set BC8022 (15 per box) for 80 planned patients, flow sensor AP188 (adult/pediatric), mainstream CO2 adapter for adult/pediatric, trolley mount with 3 trolley accessories, the US power cord, and IntelliSync+, HiFlowO2 at 60 l/min, with a HAMILTON-H900 humidifier and its integration kit, and the In2Flow M nasal cannula. The quote states 90 circuit sets in total. It is ready to send.
Verdict: Allowed.