Predictika · Reciprocating compressor valves

An AI sales agent's compressor valve quote, checked before it goes out

An AI sales agent prepares a quote for HOERBIGER reciprocating compressor valves: which valve type, the compressor speed, the pressures, the temperature range, the valve diameter and the capacity control the customer wants. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the technical data HOERBIGER publishes for each valve type and returns a verdict, every reason and the figures it computed.

Scope: HOERBIGER CE, CT, HDS, RN and HPV compressor valves: published limits for speed, pressure, pressure differential, temperature and diameter, capacity control options and hydrogen service. See everything this validator covers

This validator models a quote for one compressor valve type at a time, based on the technical data HOERBIGER publishes on its product pages and in its brochures and flyers for the CE, CT, HDS, RN and HPV valves, not just the scenarios shown below.

  • Operating limits — the most the published data allows for each valve type: compressor speed, maximum pressure, pressure differential, temperature range and valve diameter. CE: 1,200 rpm, 200 bar, 100 bar differential, -40 to 230 °C, 48 to 314 mm. CT: 1,800 rpm, 350 bar, 150 bar differential, up to 230 °C, 77 to 221 mm. HDS: 1,200 rpm, 300 bar, 100 bar differential, -160 to 300 °C, 92 to 254 mm. RN: 2,000 rpm, up to 415 bar, -40 to 300 °C, 19 to 214 mm. HPV: 1,800 rpm, 800 bar, 400 bar differential, -20 to 300 °C, 19 to 57 mm.
  • Capacity control — HydroCOM is published for the CE and CT valves, eHydroCOM for the CE valve, and only On/Off for the HDS and RN valves. A control that is not listed blocks the quote. HOERBIGER publishes no capacity control options for the HPV valve, so any control on an HPV quote goes to a person.
  • Needs approval — the HDS limits that depend on the valve plate material, the RN pressure rating (30 to 415 bar depending on valve diameter), hydrogen service on valve types where the published data does not list it (it is listed for CE and HPV), and capacity control on the HPV valve.

Any quote for these five valve types that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (HOERBIGER publishes no list prices, so there is no price build-up), the CP valve (its brochure gives no operating limits), other HOERBIGER valve families, valve materials, spare parts and services, and the compressor itself. The limits are the maxima in the published data; a real application can need a smaller envelope, which HOERBIGER confirms.

The AI sales agentBuilds the valve quote from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
Operating limits that differ for each valve typeOnly with care
Five valve types each have their own speed, pressure, differential, temperature and diameter limits, so a rule per type and limit is needed and has to be kept in step with the published data.
The limits are looked up from the chosen valve type and every one is compared with the quote on every call.
Capacity control options that only some valve types offerOnly with care
HydroCOM and eHydroCOM exist for some valves only, so a compatibility table or a rule per pair is needed.
The requested control is checked against the options published for the valve type.
Limits that depend on something not yet knownOnly with workarounds
The HDS limits depend on the valve plate material and the RN pressure rating on its diameter. A rule that treats the published maximum as the limit would pass quotes that are not yet confirmed.
These cases go to a person for approval until the dependency is confirmed, and every other finding still comes back with them.
A fact the published data does not stateOnly with workarounds
Hydrogen service is listed for some valve types and not others; a missing fact must not be silently treated as yes or as no.
A fact that is not published becomes an approval finding rather than a pass or a block.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1The compressor speed is 1,201 rpm; the selected valve type is published for at most 1,200 rpm.
2The maximum pressure is 201 bar; the selected valve type is published for at most 200 bar.
3The pressure differential is 101 bar; the selected valve type is published for at most 100 bar.
4The maximum operating temperature is 231 °C; the selected valve type is published for at most 230 °C.
5The minimum operating temperature is -41 °C; the selected valve type is published down to -40 °C.
6The valve diameter is 47 mm; the selected valve type is published from 48 mm.
7The valve diameter is 315 mm; the selected valve type is published up to 314 mm.
8The requested capacity control is not among the capacity control options published for the selected valve type.
9The maximum pressure is 351 bar; the selected valve type is published for at most 350 bar.
10The pressure differential is 151 bar; the selected valve type is published for at most 150 bar.
11The valve diameter is 70 mm; the selected valve type is published from 77 mm.
12The HDS pressure differential and temperature range are published as depending on the valve plate material; a person should confirm the limits for the chosen plate material.
13The compressor speed is 1,500 rpm; the selected valve type is published for at most 1,200 rpm.
14The RN maximum pressure is published as 30 to 415 bar depending on valve diameter; a person should confirm the rating for 200 bar at 100 mm.
15The maximum pressure is 416 bar; the selected valve type is published for at most 415 bar.
16The maximum pressure is 801 bar; the selected valve type is published for at most 800 bar.
17The pressure differential is 401 bar; the selected valve type is published for at most 400 bar.
18The maximum operating temperature is 301 °C; the selected valve type is published for at most 300 °C.
19The minimum operating temperature is -21 °C; the selected valve type is published down to -20 °C.
20The valve diameter is 58 mm; the selected valve type is published up to 57 mm.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Process gas valve limits: CE valve with speed, pressure and differential over its limits

The agent's request. Please quote a CE profiled ring valve of 250 mm for a compressor running at 1,500 rpm, with a maximum pressure of 250 bar, a pressure differential of 120 bar and an operating temperature from 0 to 150 °C, with eHydroCOM capacity control. It is ready to send.

Verdict: Blocked.

  • Compressor speed over the limit. The compressor speed is 1,500 rpm; the selected valve type is published for at most 1,200 rpm.
  • Pressure over the limit. The maximum pressure is 250 bar; the selected valve type is published for at most 200 bar.
  • Pressure differential over the limit. The pressure differential is 120 bar; the selected valve type is published for at most 100 bar.

2. Process gas valve limits: The agent resubmits after fixing the errors

The agent's request. Please quote a CE profiled ring valve of 250 mm for a compressor running at 1,100 rpm, with a maximum pressure of 180 bar, a pressure differential of 90 bar and an operating temperature from 0 to 150 °C, with eHydroCOM capacity control. It is ready to send.

Verdict: Allowed.

  • Valve limits. Published limits for the selected valve type: 1,200 rpm, 200 bar maximum pressure, diameters 48 to 314 mm.

3. Hydrogen valve and capacity control: High-pressure hydrogen valve over its pressure, with a capacity control

The agent's request. Please quote a HPV high-pressure ring valve of 40 mm for a compressor running at 1,500 rpm, with a maximum pressure of 900 bar, a pressure differential of 350 bar and an operating temperature from -10 to 200 °C, with HydroCOM capacity control. The gas is hydrogen. It is ready to send.

Verdict: Blocked.

  • Pressure over the limit. The maximum pressure is 900 bar; the selected valve type is published for at most 800 bar.
  • Capacity control options not published for HPV. The published HPV data lists no capacity control options; a person should confirm the requested control.

4. Hydrogen valve and capacity control: The agent resubmits after fixing the errors

The agent's request. Please quote a HPV high-pressure ring valve of 40 mm for a compressor running at 1,500 rpm, with a maximum pressure of 700 bar, a pressure differential of 350 bar and an operating temperature from -10 to 200 °C, with HydroCOM capacity control. The gas is hydrogen. It is ready to send.

Verdict: Needs approval.

  • Capacity control options not published for HPV. The published HPV data lists no capacity control options; a person should confirm the requested control.
  • Valve limits. Published limits for the selected valve type: 1,800 rpm, 800 bar maximum pressure, diameters 19 to 57 mm.

5. Hydrogen valve and capacity control: The agent resubmits after fixing the errors

The agent's request. Please quote a HPV high-pressure ring valve of 40 mm for a compressor running at 1,500 rpm, with a maximum pressure of 700 bar, a pressure differential of 350 bar and an operating temperature from -10 to 200 °C, with no capacity control. The gas is hydrogen. It is ready to send.

Verdict: Allowed.

  • Valve limits. Published limits for the selected valve type: 1,800 rpm, 800 bar maximum pressure, diameters 19 to 57 mm.

6. Air valve at high pressure: RN valve over its speed and pressure limits

The agent's request. Please quote a RN steel plate valve of 100 mm for a compressor running at 2,200 rpm, with a maximum pressure of 450 bar, a pressure differential of 200 bar and an operating temperature from -30 to 120 °C, with no capacity control. It is ready to send.

Verdict: Blocked.

  • Compressor speed over the limit. The compressor speed is 2,200 rpm; the selected valve type is published for at most 2,000 rpm.
  • Pressure over the limit. The maximum pressure is 450 bar; the selected valve type is published for at most 415 bar.
  • RN pressure rating depends on diameter. The RN maximum pressure is published as 30 to 415 bar depending on valve diameter; a person should confirm the rating for 450 bar at 100 mm.

7. Air valve at high pressure: The agent resubmits after fixing the errors

The agent's request. Please quote a RN steel plate valve of 100 mm for a compressor running at 1,500 rpm, with a maximum pressure of 300 bar, a pressure differential of 200 bar and an operating temperature from -30 to 120 °C, with no capacity control. The pressure rating at this diameter has been confirmed. It is ready to send.

Verdict: Allowed.

  • Valve limits. Published limits for the selected valve type: 2,000 rpm, 415 bar maximum pressure, diameters 19 to 214 mm.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares a quote for HOERBIGER reciprocating compressor valves: which valve type, the compressor speed, the pressures, and more. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the technical data HOERBIGER publishes for each valve type and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote a CE profiled ring valve of 250 mm for a compressor running at 1,500 rpm, with a maximum pressure of 250 bar. It is ready to send. The rest of the request is on screen.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with three findings, all in one answer. The compressor speed is 1,500 rpm; the selected valve type is published for at most 1,200 rpm. The maximum pressure is 250 bar; the selected valve type is published for at most 200 bar. The pressure differential is 120 bar; the selected valve type is published for at most 100 bar.
  6. The validator returned three blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for operating limits that differ for each valve type, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the compressor speed to 1,100 rpm, the maximum pressure to 180 bar and the pressure differential to 90 bar.
  10. It calls the validator again.
  11. This time the validator clears it.
  12. All three earlier findings are cleared.