Predictika · Reciprocating compressor valves
An AI sales agent prepares a quote for HOERBIGER reciprocating compressor valves: which valve type, the compressor speed, the pressures, the temperature range, the valve diameter and the capacity control the customer wants. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the technical data HOERBIGER publishes for each valve type and returns a verdict, every reason and the figures it computed.
This validator models a quote for one compressor valve type at a time, based on the technical data HOERBIGER publishes on its product pages and in its brochures and flyers for the CE, CT, HDS, RN and HPV valves, not just the scenarios shown below.
Any quote for these five valve types that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (HOERBIGER publishes no list prices, so there is no price build-up), the CP valve (its brochure gives no operating limits), other HOERBIGER valve families, valve materials, spare parts and services, and the compressor itself. The limits are the maxima in the published data; a real application can need a smaller envelope, which HOERBIGER confirms.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Operating limits that differ for each valve type | Only with care Five valve types each have their own speed, pressure, differential, temperature and diameter limits, so a rule per type and limit is needed and has to be kept in step with the published data. | The limits are looked up from the chosen valve type and every one is compared with the quote on every call. |
| Capacity control options that only some valve types offer | Only with care HydroCOM and eHydroCOM exist for some valves only, so a compatibility table or a rule per pair is needed. | The requested control is checked against the options published for the valve type. |
| Limits that depend on something not yet known | Only with workarounds The HDS limits depend on the valve plate material and the RN pressure rating on its diameter. A rule that treats the published maximum as the limit would pass quotes that are not yet confirmed. | These cases go to a person for approval until the dependency is confirmed, and every other finding still comes back with them. |
| A fact the published data does not state | Only with workarounds Hydrogen service is listed for some valve types and not others; a missing fact must not be silently treated as yes or as no. | A fact that is not published becomes an approval finding rather than a pass or a block. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The compressor speed is 1,201 rpm; the selected valve type is published for at most 1,200 rpm. |
| 2 | The maximum pressure is 201 bar; the selected valve type is published for at most 200 bar. |
| 3 | The pressure differential is 101 bar; the selected valve type is published for at most 100 bar. |
| 4 | The maximum operating temperature is 231 °C; the selected valve type is published for at most 230 °C. |
| 5 | The minimum operating temperature is -41 °C; the selected valve type is published down to -40 °C. |
| 6 | The valve diameter is 47 mm; the selected valve type is published from 48 mm. |
| 7 | The valve diameter is 315 mm; the selected valve type is published up to 314 mm. |
| 8 | The requested capacity control is not among the capacity control options published for the selected valve type. |
| 9 | The maximum pressure is 351 bar; the selected valve type is published for at most 350 bar. |
| 10 | The pressure differential is 151 bar; the selected valve type is published for at most 150 bar. |
| 11 | The valve diameter is 70 mm; the selected valve type is published from 77 mm. |
| 12 | The HDS pressure differential and temperature range are published as depending on the valve plate material; a person should confirm the limits for the chosen plate material. |
| 13 | The compressor speed is 1,500 rpm; the selected valve type is published for at most 1,200 rpm. |
| 14 | The RN maximum pressure is published as 30 to 415 bar depending on valve diameter; a person should confirm the rating for 200 bar at 100 mm. |
| 15 | The maximum pressure is 416 bar; the selected valve type is published for at most 415 bar. |
| 16 | The maximum pressure is 801 bar; the selected valve type is published for at most 800 bar. |
| 17 | The pressure differential is 401 bar; the selected valve type is published for at most 400 bar. |
| 18 | The maximum operating temperature is 301 °C; the selected valve type is published for at most 300 °C. |
| 19 | The minimum operating temperature is -21 °C; the selected valve type is published down to -20 °C. |
| 20 | The valve diameter is 58 mm; the selected valve type is published up to 57 mm. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a CE profiled ring valve of 250 mm for a compressor running at 1,500 rpm, with a maximum pressure of 250 bar, a pressure differential of 120 bar and an operating temperature from 0 to 150 °C, with eHydroCOM capacity control. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a CE profiled ring valve of 250 mm for a compressor running at 1,100 rpm, with a maximum pressure of 180 bar, a pressure differential of 90 bar and an operating temperature from 0 to 150 °C, with eHydroCOM capacity control. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a HPV high-pressure ring valve of 40 mm for a compressor running at 1,500 rpm, with a maximum pressure of 900 bar, a pressure differential of 350 bar and an operating temperature from -10 to 200 °C, with HydroCOM capacity control. The gas is hydrogen. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a HPV high-pressure ring valve of 40 mm for a compressor running at 1,500 rpm, with a maximum pressure of 700 bar, a pressure differential of 350 bar and an operating temperature from -10 to 200 °C, with HydroCOM capacity control. The gas is hydrogen. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a HPV high-pressure ring valve of 40 mm for a compressor running at 1,500 rpm, with a maximum pressure of 700 bar, a pressure differential of 350 bar and an operating temperature from -10 to 200 °C, with no capacity control. The gas is hydrogen. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a RN steel plate valve of 100 mm for a compressor running at 2,200 rpm, with a maximum pressure of 450 bar, a pressure differential of 200 bar and an operating temperature from -30 to 120 °C, with no capacity control. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a RN steel plate valve of 100 mm for a compressor running at 1,500 rpm, with a maximum pressure of 300 bar, a pressure differential of 200 bar and an operating temperature from -30 to 120 °C, with no capacity control. The pressure rating at this diameter has been confirmed. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.