Predictika · Thermal test system quotes
An AI sales agent prepares a quote for a temperature test system: the product family, test temperature range, cooling method, facility supplies and lead time. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the product line and returns a verdict, every reason and the figures it computed.
This validator models thermal test system quotes built from the product families inTEST Corporation lists in its annual report, not just the scenarios shown below.
Any thermal test system quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (this validator produces no price build-up or line-item quote), specific model numbers, Thermonics process chillers, ultra-cold storage, induction heating, test handling and other inTEST products. inTEST has not published, approved or used these rules; all customers and orders are fictional.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Temperature limits that differ by product family | Only with care Each family has its own range, so a rule per family and per end of the range; the range check also depends on the cooling method chosen on another line. | The product, range and cooling method are in one request and every limit is checked together. |
| Cooling methods that fit only some products and ranges | Only with workarounds Refrigeration, liquid carbon dioxide and liquid nitrogen each reach a different low temperature and apply only to chambers and platforms; these cross-line conditions interact. | Product, cooling and low temperature are checked together, whatever order the choices arrive in. |
| Facility supplies the customer must confirm | Only with care A dependency from a cooling or product choice to a facility line; a rule can enforce it, but each one is another rule to keep in step. | The facility lines travel with the quote and the dependencies are checked with everything else. |
| Lead time that must match the build | Only with workarounds The standard lead time adds up the product, cooling and quantity; a stated lead time is a free-entry field, so the sum and the comparison need their own maintained logic. | The lead time is computed on every call and compared with the figure the quote states and with the need date. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is saved, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote has 0 units; it needs at least one. |
| 2 | The low test temperature of 130 C is not below the high test temperature of 125 C. |
| 3 | ThermoStream air systems cover -100 C to +300 C; the quote asks for -110 C to 125 C. |
| 4 | ThermoStream air systems cover -100 C to +300 C; the quote asks for -55 C to 320 C. |
| 5 | Thermal chambers cover -190 C to +500 C; the quote asks for -200 C to 200 C. |
| 6 | A chamber range of -200 C to 200 C is near the ends of the chamber range; engineering reviews the design. |
| 7 | A chamber range of -190 C to 200 C is near the ends of the chamber range; engineering reviews the design. |
| 8 | Thermal chambers cover -190 C to +500 C; the quote asks for -100 C to 520 C. |
| 9 | A chamber range of -100 C to 520 C is near the ends of the chamber range; engineering reviews the design. |
| 10 | Thermal platforms cover -100 C to +250 C; the quote asks for -120 C to 150 C. |
| 11 | Thermal platforms cover -100 C to +250 C; the quote asks for -40 C to 270 C. |
| 12 | Thermal platform surfaces run from 7.2 to 616 square inches (quoted in whole square inches); the quote has 5. |
| 13 | Thermal platform surfaces run from 7.2 to 616 square inches (quoted in whole square inches); the quote has 700. |
| 14 | A thermal chamber or platform needs a cooling method: mechanical refrigeration, liquid nitrogen or liquid carbon dioxide. |
| 15 | ThermoStream and MobileTemp systems cool with their built-in refrigeration; a liquid nitrogen, liquid carbon dioxide or refrigeration option does not apply. |
| 16 | Mechanical refrigeration reaches about -70 C; the quote asks for -80 C, which needs liquid nitrogen. |
| 17 | Liquid carbon dioxide cooling reaches about -75 C; the quote asks for -85 C, which needs liquid nitrogen. |
| 18 | Liquid nitrogen and liquid carbon dioxide cooling need a cryogen supply line confirmed on the quote. |
| 19 | ThermoStream and MobileTemp systems need a dry air supply confirmed on the quote. |
| 20 | ThermoStream systems hold +/-0.1 C; the quote asks for +/-0 tenths of a degree. |
| 21 | MobileTemp systems are for small thermal-mass loads, up to 10 kg; the quote has 11 kg. |
| 22 | The quote states a lead time of 12 weeks, but the system on it gives 6 weeks. |
| 23 | The quote states a lead time of 2 weeks, but the system on it gives 6 weeks. |
| 24 | The customer needs the system in 10 weeks but the standard lead time is 14 weeks; expedited build needs plant scheduling approval. |
| 25 | A chamber of 150 cubic feet is beyond the standard sizes; engineering reviews the design. |
| 26 | A chamber range of -170 C to 200 C is near the ends of the chamber range; engineering reviews the design. |
| 27 | Thermal platforms cover -100 C to +250 C; the quote asks for -40 C to 300 C. |
| 28 | The quote states a lead time of 5 weeks, but the system on it gives 10 weeks. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 2 x ThermoStream air systems for -120 C to 125 C, stability +/-0.1 C. The customer needs the system in 12 weeks and the quote states a standard lead time of 6 weeks. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 x ThermoStream air systems for -90 C to 125 C, stability +/-0.1 C, with the customer's dry air supply confirmed. The customer needs the system in 12 weeks and the quote states a standard lead time of 6 weeks. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 x thermal chamber for -120 C to 200 C, 40 cubic feet with liquid carbon dioxide cooling, with the customer's cryogen supply confirmed. The customer needs the system in 14 weeks and the quote states a standard lead time of 14 weeks. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 x thermal chamber for -120 C to 200 C, 40 cubic feet with liquid nitrogen cooling, with the customer's cryogen supply confirmed. The customer needs the system in 12 weeks and the quote states a standard lead time of 14 weeks. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 1 x thermal chamber for -120 C to 200 C, 40 cubic feet with liquid nitrogen cooling, with the customer's cryogen supply confirmed. The customer needs the system in 16 weeks and the quote states a standard lead time of 14 weeks. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 x thermal platform for -40 C to 270 C, 700 square inch surface. The customer needs the system in 14 weeks and the quote states a standard lead time of 6 weeks. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 x thermal platform for -40 C to 200 C, 400 square inch surface with mechanical refrigeration. The customer needs the system in 14 weeks and the quote states a standard lead time of 11 weeks. It is ready to send.
Verdict: Allowed.