Predictika · Network infrastructure
An AI sales agent prepares an order for Trinzic X6 enterprise DNS, DHCP and IPAM (DDI) appliances: a physical or a software appliance, the model, whether it serves DDI or reporting and analytics, power supplies, NIC card, transceivers, rail kit, deployment platform, indexing capacity and licenses, with the rack units and DNS rate it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the tables in the public Trinzic X6 datasheet and returns a verdict, every reason and the figures it computed.
This validator models one product line, the Trinzic X6 enterprise DNS, DHCP and IPAM (DDI) appliances in the public Trinzic X6 datasheet (version 20260902v4), for any order that touches the rules below, not just the scenarios shown here.
Any order for this product line that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the datasheet publishes none, so this page shows no price build-up), part numbers and SKUs, Network Insight (ND) software, NIOS subscription tiers, Trinzic X5 appliances, Threat Defense, support and warranty upgrades, and CPU, RAM and storage sizing for a particular hypervisor or cloud. The datasheet states that performance numbers are lab reference figures and that some models support only a subset of options, so the final configuration is confirmed with the vendor.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Which options each model offers: single power supply, DC power, NIC card, transceivers | Only with workarounds The options differ by model (the TE-906 has no DC power, no 10GE card and no transceivers; a single power supply exists only on two models). A rules-based CPQ needs a compatibility table or one rule per model and option, and a new datasheet means editing them. | Model and options arrive in one request and are checked together on every call. |
| Reporting hosted only from the TE-1606 up, with a daily indexing limit per model | Only with workarounds Whether reporting can be hosted, and the largest indexing tier, depend on the model; the valid tiers are a separate list. Rules usually cover the list or the model limit, rarely both. | Model, role and indexing tier are compared together, in any order. |
| Rail kit against the rack posts and depth | Only with care A kit is valid only for one rack type and depth range, so the rule has to read two rack fields and the chosen kit. | The kit, posts and depth are compared on every call. |
| Stated rack units and DNS rate against the datasheet | Only with care A figure the agent states is just text to a rules-based CPQ unless someone builds a calculation and a comparison for each size. | The units, the size and the datasheet rate are computed on every call, and a difference blocks the order. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The order has 0 appliances; at least 1 is needed. |
| 2 | An HA pair is two appliances; the order has 3. |
| 3 | The TE-1606 comes with two hot-swappable power supplies; a single power supply is offered only on the TE-906 and TE-1506. |
| 4 | A physical appliance has one or two power supplies; the order has 3. |
| 5 | The TE-906 has no DC power supply option. |
| 6 | The DC power supply is a SKU option for telco use only. |
| 7 | The optional quad 10GE NIC card is not available on the TE-906. |
| 8 | The 4 port 1GE NIC card is the TE-906 option; the TE-1606 offers no card or the quad 10GE NIC card. |
| 9 | The TE-906 has no SFP transceiver interfaces. |
| 10 | An appliance has four SFP or SFP+ interfaces; the order has 5 transceivers. |
| 11 | The datasheet lists the four SFP or SFP+ interfaces with the 10GE NIC card options; a person should confirm that 2 transceiver(s) can be fitted without the card. |
| 12 | The 2-post rail kit fits a 2-post rack; the rack has 4 posts. |
| 13 | The 4-post rail kits fit a 4-post rack; the rack has 2 posts. |
| 14 | The up-to-600 mm 4-post rail kit needs a rack no deeper than 600 mm; the rack is 750 mm deep. |
| 15 | The 600 to 900 mm 4-post rail kit needs a rack between 600 and 900 mm deep; the rack is 1,000 mm deep. |
| 16 | The order states 3 rack units in total; 2 appliance(s) of this model occupy 2. |
| 17 | The order states 2 rack units in total; 2 appliance(s) of this model occupy 4. |
| 18 | A software appliance needs a hypervisor or cloud platform to run on. |
| 19 | Power supplies, power type, NIC cards, transceivers and rail kits apply only to physical appliances. |
| 20 | A deployment target applies only to software appliances. |
| 21 | The order states 300,000 DNS queries per second per appliance; the datasheet lists 250,000 for this size. |
| 22 | The TE-1506 does not host reporting and analytics software; the datasheet lists it from the TE-1606 up. |
| 23 | The TE-1606 appliance hosts reporting up to 10 GB per day; the order asks for 20,000 MB. |
| 24 | 15 GB per day is not an available indexing capacity; the tiers are 500 MB and 1, 2, 5, 10, 20, 50, 100, 200 and 500 GB. |
| 25 | The TR-5005 software appliance runs on VMware ESXi, Hyper-V, Nutanix AHV and OpenStack KVM, and in AWS and Azure; Google Cloud and OCI are not listed. |
| 26 | Indexing capacity applies only to reporting and analytics appliances. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 2 physical TE-2306 appliances as an HA pair for DNS, DHCP and IPAM, each with 2 power supplies, DC for a telco site, the quad 10GE NIC card, 4 SFP transceivers and the 600 to 900 mm 4-post rail kit, for a 4-post rack 750 mm deep, on the Trinzic X6 subscription. The order states 2 rack units in total and 250,000 DNS queries per second per appliance. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 physical TE-2306 appliances as an HA pair for DNS, DHCP and IPAM, each with 2 power supplies, AC, the quad 10GE NIC card, 4 SFP transceivers and the 600 to 900 mm 4-post rail kit, for a 4-post rack 750 mm deep, on the Trinzic X6 subscription. The order states 4 rack units in total and 250,000 DNS queries per second per appliance. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 TR-5005 reporting and analytics software appliance for Google Cloud, indexing 15 GB per day, on the Trinzic X6 subscription. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 TR-5005 reporting and analytics software appliance for AWS, indexing 15 GB per day, on the Trinzic X6 subscription. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 TR-5005 reporting and analytics software appliance for AWS, indexing 20 GB per day, on the Trinzic X6 subscription. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 2 physical TE-1506 appliances as an HA pair for DNS, DHCP and IPAM, each with 1 power supply, AC, no NIC card, 4 SFP transceivers and the up-to-600 mm 4-post rail kit, for a 4-post rack 600 mm deep, on the Trinzic X6 subscription plus a separate DNS Firewall license. The order states 2 rack units in total and 67,500 DNS queries per second per appliance. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 2 physical TE-1506 appliances as an HA pair for DNS, DHCP and IPAM, each with 1 power supply, AC, the quad 10GE NIC card, 4 SFP transceivers and the up-to-600 mm 4-post rail kit, for a 4-post rack 600 mm deep, on the Trinzic X6 subscription. The order states 2 rack units in total and 67,500 DNS queries per second per appliance. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.