Predictika · Food freezing equipment

An AI sales agent's GYRoCOMPACT 60 spiral freezer, checked before it goes out

An AI sales agent sizes a Frigoscandia GYRoCOMPACT 60 spiral freezer for a food producer: the variant (60/2, 60/2B or 60/3), the number of tiers, the belt link height and product height, the belt mesh, the defrost method, the electrical supply, and the normal power and base load it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures in the public JBT brochure and returns a verdict, every reason and the figures it computed.

Scope: GYRoCOMPACT 60 spiral freezers in the 60/2, 60/2B and 60/3 variants: tiers, belt link height and product clearance, mesh, defrost, supply and stated power. See everything this validator covers

This validator models one GYRoCOMPACT 60 spiral freezer at a time, based on the public JBT brochure "Frigoscandia GYRoCOMPACT 60" (B 3221-EN 2403), not just the scenarios shown below.

  • Tiers — the brochure lists 16 to 48 tiers for the 60/2 and 16 to 42 tiers for the 60/3; the 60/2B is listed with no tier range of its own, so a 60/2B quote goes to a person to confirm the tier count.
  • Belt link height and product clearance — link heights of 65, 80, 100, 120 and 150 mm give 50, 65, 85, 105 and 135 mm of vertical clearance, and the product must fit within it.
  • Defrost — hot gas or potable water; water defrost needs water at 15 to 25 C and at least 1 bar (3 bar nominal).
  • Supply and stated power — three-phase 380 to 480 V or 575 V at 50 or 60 Hz; the normal power and base load the quote states must equal the brochure figures for the variant (28 and 31 kW for the 60/2, 14 and 16 kW for the 60/2B, 39 and 50 kW for the 60/3). A refrigerant other than R717 (ammonia) goes to a person.

Any GYRoCOMPACT 60 quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none are modeled), freezing capacity and product-specific freezing times, building and installation layout, and other JBT freezer models.

The AI sales agentSizes the freezer from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
Tier limits that differ by variant (48 and 42)Only with care
The allowed tier range is different for each variant, so a rules-based CPQ needs a rule or table row per variant.
The variant and tier count arrive in one request and are compared with the limits for that variant on every call.
Product clearance that depends on the belt link heightOnly with workarounds
The clearance is a function of the chosen link height, so a lookup has to be maintained and compared with the product height.
The clearance is derived from the link height and compared with the product height on every call.
Water defrost limits that apply only to water defrostOnly with care
Temperature, pressure and potable-water rules apply only when water is the defrost medium, so each needs a condition.
The conditions are part of the model and are checked together with the other rules.
Stated power and base load that must match the variantOnly with care
The stated figures have to be compared with the variant's figures after every change of variant.
The stated figures are fields in the request, compared with the variant's figures on every call.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1The brochure lists the low-energy 60/2B only in its electrical and refrigeration tables, with no tier range of its own, so a person should confirm the tier count.
249 tiers are planned; the selected variant is listed with 16 to 48 tiers.
315 tiers are planned; the selected variant is listed with 16 to 48 tiers.
443 tiers are planned; the selected variant is listed with 16 to 42 tiers.
5Product 51 mm high does not fit the 50 mm of vertical clearance the selected link height gives.
6Product 86 mm high does not fit the 85 mm of vertical clearance the selected link height gives.
7Product 136 mm high does not fit the 135 mm of vertical clearance the selected link height gives.
8A link height of 90 mm is not available; the belt comes in link heights of 65, 80, 100, 120 and 150 mm.
9The defrost water is at 14 C; the brochure lists a minimum of 15 C and a maximum of 25 C.
10The defrost water is at 26 C; the brochure lists a minimum of 15 C and a maximum of 25 C.
11The defrost water pressure is 0.9 bar; the brochure lists a minimum of 1 bar (3 bar nominal).
12The brochure requires potable water for water defrost.
13A supply of 500 V is not listed; the brochure lists three-phase 380 to 480 V and 575 V.
14A supply of 370 V is not listed; the brochure lists three-phase 380 to 480 V and 575 V.
15A supply of 481 V is not listed; the brochure lists three-phase 380 to 480 V and 575 V.
16A supply frequency of 55 Hz is not listed; the brochure lists 50 and 60 Hz.
17The quote states 29 kW normal power; the brochure lists 28 kW for the selected variant.
18The quote states 31 kW base load; the brochure lists 50 kW for the selected variant.
19The quote states 28 kW normal power; the brochure lists 14 kW for the selected variant.
20The quote states 31 kW base load; the brochure lists 16 kW for the selected variant.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Water defrost and supply: A 60/2 with water defrost at 12 C and 0.8 bar on a 500 V supply

The agent's request. Please quote a GYRoCOMPACT 60 spiral freezer, variant 60/2, with 36 tiers, 100 mm belt link height and 70 mm high product, M13 mesh, and water defrost with water at 12 C and 0.8 bar. The supply is 500 V at 50 Hz and the refrigerant is R717 (ammonia). The Air Defrost (ADF) option is included. The quote states 28 kW normal power and 31 kW base load. It is ready to send.

Verdict: Blocked.

  • Defrost water temperature outside the range. The defrost water is at 12 C; the brochure lists a minimum of 15 C and a maximum of 25 C.
  • Defrost water pressure too low. The defrost water pressure is 0.8 bar; the brochure lists a minimum of 1 bar (3 bar nominal).
  • Supply voltage not listed. A supply of 500 V is not listed; the brochure lists three-phase 380 to 480 V and 575 V.

2. Water defrost and supply: The agent resubmits after fixing the errors

The agent's request. Please quote a GYRoCOMPACT 60 spiral freezer, variant 60/2, with 36 tiers, 100 mm belt link height and 70 mm high product, M13 mesh, and water defrost with water at 18 C and 2.5 bar. The supply is 480 V at 50 Hz and the refrigerant is R717 (ammonia). The Air Defrost (ADF) option is included. The quote states 28 kW normal power and 31 kW base load. It is ready to send.

Verdict: Allowed.

  • System summary. 36 tiers give a belt length of 403.2 m and an effective belt area of 205.2 m2; the selected variant lists 28 kW normal power and 31 kW base load.

3. Tiers and product clearance: A 60/3 with 44 tiers and a 90 mm product on 80 mm belt links

The agent's request. Please quote a GYRoCOMPACT 60 spiral freezer, variant 60/3, with 44 tiers, 80 mm belt link height and 90 mm high product, M9 mesh, and hot gas defrost. The supply is 400 V at 50 Hz and the refrigerant is R717 (ammonia). The quote states 39 kW normal power and 50 kW base load. It is ready to send.

Verdict: Blocked.

  • Number of tiers not available. 44 tiers are planned; the selected variant is listed with 16 to 42 tiers.
  • Product too tall for the belt. Product 90 mm high does not fit the 65 mm of vertical clearance the selected link height gives.

4. Tiers and product clearance: The agent resubmits after fixing the errors

The agent's request. Please quote a GYRoCOMPACT 60 spiral freezer, variant 60/3, with 42 tiers, 120 mm belt link height and 90 mm high product, M9 mesh, and hot gas defrost. The supply is 400 V at 50 Hz and the refrigerant is R717 (ammonia). The quote states 39 kW normal power and 50 kW base load. It is ready to send.

Verdict: Allowed.

  • System summary. 42 tiers give a belt length of 470.4 m and an effective belt area of 239.4 m2; the selected variant lists 39 kW normal power and 50 kW base load.

5. Stated power and refrigerant: A 60/3 stated at the 60/2 power figures with a refrigerant other than R717

The agent's request. Please quote a GYRoCOMPACT 60 spiral freezer, variant 60/3, with 30 tiers, 100 mm belt link height and 70 mm high product, M6 mesh, and hot gas defrost. The supply is 400 V at 50 Hz and the refrigerant is not R717. The quote states 28 kW normal power and 31 kW base load. It is ready to send.

Verdict: Blocked.

  • Stated power differs from the brochure. The quote states 28 kW normal power; the brochure lists 39 kW for the selected variant.
  • Stated base load differs from the brochure. The quote states 31 kW base load; the brochure lists 50 kW for the selected variant.
  • Refrigerant other than R717. The standard design uses R717 (ammonia); the brochure describes no other refrigerant, so a person should confirm it.

6. Stated power and refrigerant: The agent resubmits after fixing the errors

The agent's request. Please quote a GYRoCOMPACT 60 spiral freezer, variant 60/3, with 30 tiers, 100 mm belt link height and 70 mm high product, M6 mesh, and hot gas defrost. The supply is 400 V at 50 Hz and the refrigerant is not R717. The quote states 39 kW normal power and 50 kW base load. It is ready to send.

Verdict: Needs approval.

  • Refrigerant other than R717. The standard design uses R717 (ammonia); the brochure describes no other refrigerant, so a person should confirm it.
  • System summary. 30 tiers give a belt length of 336.0 m and an effective belt area of 171.0 m2; the selected variant lists 39 kW normal power and 50 kW base load.

7. Stated power and refrigerant: The agent resubmits after fixing the errors

The agent's request. Please quote a GYRoCOMPACT 60 spiral freezer, variant 60/3, with 30 tiers, 100 mm belt link height and 70 mm high product, M6 mesh, and hot gas defrost. The supply is 400 V at 50 Hz and the refrigerant is R717 (ammonia). The quote states 39 kW normal power and 50 kW base load. It is ready to send.

Verdict: Allowed.

  • System summary. 30 tiers give a belt length of 336.0 m and an effective belt area of 171.0 m2; the selected variant lists 39 kW normal power and 50 kW base load.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent sizes a Frigoscandia GYRoCOMPACT 60 spiral freezer for a food producer: the variant (60/2, 60/2B or 60/3), the number of tiers, the belt link height and product height, and more. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures in the public JBT brochure and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote a GYRoCOMPACT 60 spiral freezer, variant 60/2, with 36 tiers, 100 mm belt link height and 70 mm high product. The supply is 500 V at 50 Hz and the refrigerant is R717 (ammonia). The rest of the request is on screen.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with three findings, all in one answer. The defrost water is at 12 C; the brochure lists a minimum of 15 C and a maximum of 25 C. The defrost water pressure is 0.8 bar; the brochure lists a minimum of 1 bar (3 bar nominal). A supply of 500 V is not listed; the brochure lists three-phase 380 to 480 V and 575 V.
  6. The validator returned three blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for water defrost limits that apply only to water defrost, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the defrost water temperature to 18 C, the defrost water pressure to 2.5 bar and the supply to 480 V.
  10. It calls the validator again.
  11. This time the validator clears it.
  12. All three earlier findings are cleared.
  13. Three problems caught in one call, fixed in one pass, and a clean quote. That is the value of Predictika's validator: catching mistakes before they reach the customer.