Predictika · Flowmeter orders
An AI sales agent prepares an order for KROHNE OPTIFLUX 2000 electromagnetic flowmeters: nominal size, signal converter, liner, flange standard, process temperature and pressure, and options such as legal metrology, IP68 and the virtual reference. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the limits in the public OPTIFLUX 2000 datasheet and returns a verdict, every reason and the figures it computed.
This validator models orders for the OPTIFLUX 2000 sensor built from the public datasheet limits below, not just the scenarios shown.
Any OPTIFLUX 2000 order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none were used, so this validator produces no price build-up or line-item quote), other KROHNE meters, the vacuum-load table, pressure ratings for ASME and JIS flanges, ambient temperature limits, electrode and ring materials beyond the virtual reference, and the optional hard rubber liner for DN25 to DN150 that only one datasheet copy lists. Nominal sizes are limited to those named in the datasheet tables (DN25, 50, 65, 80, 100, 150, 200, 700, 1000, 1200, 1600, 1800, 2000, 2200 and 3000).
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A liner that depends on the nominal size, with a temperature limit that depends on the liner | Only with care The liner follows from the size and the option chosen, and the temperature limit follows from the liner, so each link needs its own rule and a calculated field. | The size, liner option and temperature are in one request and the liner limit is derived and checked on every call. |
| A signal converter that limits the size range and unlocks options such as legal metrology and the virtual reference | Only with workarounds One choice constrains several others, so each pairing needs a rule and the set grows with every option. | The converter is checked against size, legal metrology, grounding, conductivity and cable length in one pass. |
| A flange rating that depends on the size and the flange standard, compared with the operating pressure | Only with care The rating is a lookup by size and standard, and a separate validation rule compares it with the pressure. | The rating is computed from the size and standard and compared with both the pressure and the rating the agent stated. |
| An accuracy that follows from the converter and the size, compared with what the agent stated | Only with workarounds These are formulas rather than choices, so they need calculated fields and a rule that compares them with the stated figure. | The accuracy is computed from the order and compared with the agent's stated figure. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The order has 0 flowmeters; at least 1 is needed. |
| 2 | A nominal size of DN90 is not one of the sizes named in the datasheet tables that this validator covers (DN25, 50, 65, 80, 100, 150, 200, 700, 1000, 1200, 1600, 1800, 2000, 2,200 and 3,000). |
| 3 | A nominal size of DN1600 is above DN1200, the largest size this signal converter covers. |
| 4 | A nominal size of DN2000 is above DN1200, the largest size this signal converter covers. |
| 5 | The optional polyolefin liner is offered for DN200 to DN1000 only; the order is DN150. |
| 6 | The optional polyolefin liner is offered for DN200 to DN1000 only; the order is DN1200. |
| 7 | A process temperature of 91 degrees C is outside the -5 to +90 degrees C range of the liner that comes with this size and liner option. |
| 8 | A process temperature of 81 degrees C is outside the -5 to +80 degrees C range of the liner that comes with this size and liner option. |
| 9 | A process temperature of -6 degrees C is outside the -5 to +90 degrees C range of the liner that comes with this size and liner option. |
| 10 | The selected flange standard is not offered at DN700 (ASME B16.5 covers 1 to 24 inch, JIS DN25 to DN1000, AWWA DN700 to DN1000 and DN1200 to DN2000). |
| 11 | The selected flange standard is not offered at DN1200 (ASME B16.5 covers 1 to 24 inch, JIS DN25 to DN1000, AWWA DN700 to DN1000 and DN1200 to DN2000). |
| 12 | The selected flange standard is not offered at DN200 (ASME B16.5 covers 1 to 24 inch, JIS DN25 to DN1000, AWWA DN700 to DN1000 and DN1200 to DN2000). |
| 13 | The operating pressure of 16.1 bar is above the flange rating of 16 bar at this size. |
| 14 | The operating pressure of 17 bar is above the flange rating of 16 bar at this size. |
| 15 | The operating pressure of 7 bar is above the flange rating of 6 bar at this size. |
| 16 | The operating pressure of 2.6 bar is above the flange rating of 2.5 bar at this size. |
| 17 | Legal metrology approval (OIML R49, MID) is only available in combination with the IFC 300 signal converter. |
| 18 | Protection class IP68 is only available for the separate (remote) design. |
| 19 | Protection class IP68 is only available with a stainless steel connection box. |
| 20 | The virtual reference option (no grounding rings) is only available with the IFC 300 signal converter. |
| 21 | The virtual reference option needs a conductivity of at least 200 microsiemens per cm; the medium has 199. |
| 22 | With the virtual reference option the electrode cable is limited to 50 m; the order has 51 m. |
| 23 | A conductivity of 4 microsiemens per cm is below the minimum of 5. |
| 24 | Demineralised water needs a conductivity of at least 20 microsiemens per cm; the medium has 19. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 6 OPTIFLUX 2000 flowmeters, DN1800, with the IFC 100 signal converter in the compact design, the standard liner for the size and ASME B16.5 flanges, for a process temperature of 25 degrees C, an operating pressure of 5 bar, a medium conductivity of 800 microsiemens per cm and a flow velocity of 4 m/s, with standard stainless steel grounding rings. The quote states an accuracy of 0.20 percent of the measured value. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 6 OPTIFLUX 2000 flowmeters, DN1800, with the IFC 300 signal converter in the compact design, the standard liner for the size and EN 1092-1 flanges, for a process temperature of 25 degrees C, an operating pressure of 5 bar, a medium conductivity of 800 microsiemens per cm and a flow velocity of 4 m/s, with standard stainless steel grounding rings. The quote states an accuracy of 0.30 percent of the measured value and a flange rating of 6 bar. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 12 OPTIFLUX 2000 flowmeters, DN150, with the IFC 100 signal converter in the compact design, the optional polyolefin liner and EN 1092-1 flanges, for a process temperature of 85 degrees C, an operating pressure of 8 bar, a medium conductivity of 600 microsiemens per cm and a flow velocity of 3 m/s, with legal metrology approval and standard stainless steel grounding rings. The quote states an accuracy of 0.30 percent of the measured value and a flange rating of 16 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 12 OPTIFLUX 2000 flowmeters, DN150, with the IFC 300 signal converter in the compact design, the optional polyolefin liner and EN 1092-1 flanges, for a process temperature of 85 degrees C, an operating pressure of 8 bar, a medium conductivity of 600 microsiemens per cm and a flow velocity of 3 m/s, with legal metrology approval and standard stainless steel grounding rings. The quote states an accuracy of 0.20 percent of the measured value and a flange rating of 16 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 12 OPTIFLUX 2000 flowmeters, DN150, with the IFC 300 signal converter in the compact design, the standard liner for the size and EN 1092-1 flanges, for a process temperature of 85 degrees C, an operating pressure of 8 bar, a medium conductivity of 600 microsiemens per cm and a flow velocity of 3 m/s, with legal metrology approval and standard stainless steel grounding rings. The quote states an accuracy of 0.20 percent of the measured value and a flange rating of 16 bar. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 8 OPTIFLUX 2000 flowmeters, DN100, with the IFC 100 signal converter in the compact design, the standard liner for the size and EN 1092-1 flanges, for a process temperature of 30 degrees C, an operating pressure of 6 bar, a medium conductivity of 25 microsiemens per cm (demineralised water) and a flow velocity of 2 m/s, with IP68 protection (with a stainless steel connection box), the virtual reference option instead of grounding rings and vacuum service. The quote states an accuracy of 0.30 percent of the measured value and a flange rating of 16 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 8 OPTIFLUX 2000 flowmeters, DN100, with the IFC 100 signal converter in the remote design, the standard liner for the size and EN 1092-1 flanges, for a process temperature of 30 degrees C, an operating pressure of 6 bar, a medium conductivity of 25 microsiemens per cm (demineralised water) and a flow velocity of 2 m/s, with IP68 protection (with a stainless steel connection box), standard stainless steel grounding rings and vacuum service. The quote states an accuracy of 0.30 percent of the measured value and a flange rating of 16 bar. It is ready to send.
Verdict: Needs approval.
The text of the narrated walkthrough, step by step.