Predictika · DC fast-charging site configuration: power unit, power modules and charging satellites
An AI sales agent prepares a configuration for a DC fast-charging site: a power unit of 50 kW power modules, the charging satellites hanging off it, the cable length, the connectors and the power the site needs at peak. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published data sheet limits and returns a verdict, every reason and the figures it computed.
This validator models site configurations built from one product line, the Kempower Power Unit (C501, C502, C503) with Satellite V2 charging outputs, not just the scenarios shown below.
Any configuration of these power units with Satellite V2 outputs is in scope — not only the scenarios pictured here. Not covered: prices (no public price list was found, so this validator produces no price build-up or line-item quote), grid connection and fuse sizing, output voltage and power sharing between outputs, the C800 power unit and other satellite versions, liquid-cooled cables, software tiers, installation and service terms.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Module count that depends on the cabinet | Only with care Each power unit holds a different number of 50 kW modules, so the limit depends on the cabinet chosen and needs a rule per cabinet. | The cabinet and the module count arrive together and are checked on every call. |
| Output count that depends on the voltage system | Only with workarounds A dual satellite counts as two outputs and the limit is 8 or 6 depending on the voltage system, so the count and the limit depend on several choices at once. | Satellites and voltage system are in one request; outputs are counted and compared with the limit on every call. |
| Connector limits across lines | Only with care CHAdeMO current and CHAdeMO availability on dual satellites relate separate lines of the quote, which needs cross-line rules. | Connector, current and satellite type are checked together on every call. |
| Stated power that must match the modules | Only with care A stated figure is a free-entry field; a rule can compare it with the installed power, but someone has to write and maintain that comparison. | The stated power travels with the configuration and is compared with the computed power on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote has 5 power modules of 50 kW; the selected power unit takes between 1 and 4. |
| 2 | The quote has 9 power modules of 50 kW; the selected power unit takes between 1 and 8. |
| 3 | The quote has 13 power modules of 50 kW; the selected power unit takes between 1 and 12. |
| 4 | The quote has 0 power modules of 50 kW; the selected power unit takes between 1 and 8. |
| 5 | The quote has 9 charging outputs (a dual satellite has two); one power unit supports at most 8 (8, or 6 with adaptive voltage). |
| 6 | The quote has 7 charging outputs (a dual satellite has two); one power unit supports at most 6 (8, or 6 with adaptive voltage). |
| 7 | The quote has 8 charging outputs (a dual satellite has two); one power unit supports at most 6 (8, or 6 with adaptive voltage). |
| 8 | The site needs 401 kW of charging power at peak; the installed power modules give 400 kW. |
| 9 | The site needs 350 kW of charging power at peak; the installed power modules give 300 kW. |
| 10 | The quote asks for a 6 m charging cable; satellites come with 5 m or 7 m cables. |
| 11 | The quote asks for a 10 m charging cable; satellites come with 5 m or 7 m cables. |
| 12 | A CHAdeMO output is quoted at 126 A; CHAdeMO outputs are limited to 125 A. |
| 13 | The quote has 3 CHAdeMO outputs; a CHAdeMO output comes on a dual satellite with CCS2 and CHAdeMO, and the quote has 2 dual satellites. |
| 14 | The quote has 1 CHAdeMO outputs; a CHAdeMO output comes on a dual satellite with CCS2 and CHAdeMO, and the quote has 0 dual satellites. |
| 15 | The quote states 600 kW of installed power; the power modules give 400 kW. |
| 16 | The quote states 350 kW of installed power; the power modules give 400 kW. |
| 17 | A CCS2 output is quoted at 301 A, above the 300 A continuous rating the data sheets agree on; the higher-current options need a person to confirm the cable and terminals. |
| 18 | A CCS2 output is quoted at 500 A, above the 300 A continuous rating the data sheets agree on; the higher-current options need a person to confirm the cable and terminals. |
| 19 | The site needs 450 kW of charging power at peak; the installed power modules give 400 kW. |
| 20 | A CCS2 output is quoted at 375 A, above the 300 A continuous rating the data sheets agree on; the higher-current options need a person to confirm the cable and terminals. |
| 21 | The quote has 6 power modules of 50 kW; the selected power unit takes between 1 and 4. |
| 22 | The quote has 10 charging outputs (a dual satellite has two); one power unit supports at most 6 (8, or 6 with adaptive voltage). |
| 23 | The site needs 500 kW of charging power at peak; the installed power modules give 300 kW. |
| 24 | A CHAdeMO output is quoted at 200 A; CHAdeMO outputs are limited to 125 A. |
| 25 | The quote has 4 CHAdeMO outputs; a CHAdeMO output comes on a dual satellite with CCS2 and CHAdeMO, and the quote has 3 dual satellites. |
| 26 | The quote states 200 kW of installed power; the power modules give 300 kW. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a Kempower power unit: a single-cabinet C501 with 6 power modules, 4 single and 3 dual charging satellites with 6 m cables, CCS2 outputs at 250 A and 350 kW needed at peak. The quote states 400 kW of installed power. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Kempower power unit: a double-cabinet C502 with 8 power modules, 4 single and 2 dual charging satellites with 7 m cables, CCS2 outputs at 250 A and 380 kW needed at peak. The quote states 400 kW of installed power. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Kempower power unit: a triple-cabinet C503 with 12 power modules on an adaptive voltage system, 2 single and 3 dual charging satellites with 7 m cables, 4 CHAdeMO outputs at 200 A, CCS2 outputs at 250 A and 500 kW needed at peak. The quote states 600 kW of installed power. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Kempower power unit: a triple-cabinet C503 with 12 power modules on an adaptive voltage system, 2 single and 2 dual charging satellites with 7 m cables, 2 CHAdeMO outputs at 125 A, CCS2 outputs at 250 A and 500 kW needed at peak. The quote states 600 kW of installed power. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Kempower power unit: a double-cabinet C502 with 8 power modules, 1 single and 3 dual charging satellites with 5 m cables, CCS2 outputs at 400 A and 450 kW needed at peak. The quote states 400 kW of installed power. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Kempower power unit: a double-cabinet C502 with 8 power modules, 1 single and 3 dual charging satellites with 5 m cables, CCS2 outputs at 400 A and 400 kW needed at peak. The quote states 400 kW of installed power. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a Kempower power unit: a double-cabinet C502 with 8 power modules, 1 single and 3 dual charging satellites with 5 m cables, CCS2 outputs at 300 A and 400 kW needed at peak. The quote states 400 kW of installed power. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.