Predictika · VRF HVAC system quotes
An AI sales agent prepares a quote that pairs an LG Multi V 5 outdoor unit with a list of indoor units. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published system rules and returns a verdict, every reason and the figures it computed.
This validator models Multi V 5 system quotes of this kind, not just the scenarios shown below.
Any Multi V 5 system quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (LG does not publish VRF list prices, so this validator produces no price build-up or line-item quote), piping length and elevation limits (the manual points to LATS software for these), heat recovery and multi-frame systems, other LG product lines, and indoor unit types beyond the nine sizes modeled. Assumptions: indoor and outdoor capacities are the nominal Btu/h figures read from LG's public documents, and a LATS report on the quote is taken at its word.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Total indoor capacity within 50% to 130% of the outdoor unit | Only with care The indoor units are separate lines; a rule has to roll up their capacities and compare the sum with the outdoor unit on the header, and the summing has to be kept in step with the model list. | The indoor units and the outdoor unit are in one request, and the ratio is computed and checked with the rest. |
| Most indoor units a given outdoor model can connect | Only with care A product rule per outdoor model. It works, but each new model is another rule to maintain. | The limit is looked up from the outdoor model and checked together with the ratio. |
| A stated capacity that must equal the sum of the listed indoor units | Only with care A stated figure is a free-entry field; a rule can compare it with a rolled-up total, but it has to be written and maintained per quote shape. | The stated capacity travels with the quote and is compared with the computed total on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The indoor units total 193,600 Btu/h, which is 134% of the 144,000 Btu/h outdoor unit, above the 130% maximum for the system combination ratio. |
| 2 | The indoor units total 38,400 Btu/h, which is 40% of the 96,000 Btu/h outdoor unit, below the 50% minimum for the system combination ratio. |
| 3 | The quote has 36 indoor units; this outdoor unit connects at most 35. |
| 4 | The quote states 150,000 Btu/h of indoor capacity; the indoor units listed give 145,200 Btu/h. |
| 5 | LG requires LATS software on all projects to ensure correct refrigerant line sizing and the quote has no LATS report; a person should confirm it before the quote goes out. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote an LG Multi V 5 12-ton ARUM144 outdoor unit with 8 ARNU24 indoor units. The quote states 190,000 Btu/h of indoor capacity in total, and a LATS line-sizing report is attached. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote an LG Multi V 5 14-ton ARUM168 outdoor unit with 8 ARNU24 indoor units. The quote states 193,600 Btu/h of indoor capacity in total, and a LATS line-sizing report is attached. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote an LG Multi V 5 18-ton ARUM216 outdoor unit with 40 ARNU07 indoor units. The quote states 300,000 Btu/h of indoor capacity in total, and a LATS line-sizing report is attached. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote an LG Multi V 5 18-ton ARUM216 outdoor unit with 36 ARNU07 indoor units. The quote states 270,000 Btu/h of indoor capacity in total, and a LATS line-sizing report is attached. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote an LG Multi V 5 18-ton ARUM216 outdoor unit with 35 ARNU07 indoor units. The quote states 262,500 Btu/h of indoor capacity in total, and a LATS line-sizing report is attached. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote an LG Multi V 5 14-ton ARUM168 outdoor unit with 4 ARNU12, 4 ARNU18 and 3 ARNU24 indoor units. The quote states 198,200 Btu/h of indoor capacity in total. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote an LG Multi V 5 14-ton ARUM168 outdoor unit with 4 ARNU12, 4 ARNU18 and 3 ARNU24 indoor units. The quote states 198,200 Btu/h of indoor capacity in total, and a LATS line-sizing report is attached. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.