Predictika · Building products
An AI sales agent prepares an order and installation plan for a contractor: LP SmartSide 38 Series vertical siding with battens, the sheathing and water-resistive barrier behind it, the fasteners and their spacing, the batten size and nailing, and the joints at floors and masonry. Before the order goes out, the agent sends it to Predictika, which checks it against a declarative model of LP's published technical note and returns a verdict, every reason and the nail total it computed.
This validator models board and batten orders for LP SmartSide 38 Series vertical siding, not just the scenarios shown below.
Any board and batten order for this siding is in scope — not only the scenarios pictured here. Not covered: prices (LP does not publish them), other LP siding products and the accessory, trim and lap siding instructions, local building codes, the batten nail pattern beyond the end nails, and the warranty itself. The model reflects Technical Note 028 as last revised on May 13, 2022; always use LP's current instructions.
6 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Minimums and maximums from the installation note (nail spacing, gaps, penetration) | Only with care Each limit is a product or validation rule, written and kept up to date by hand; a limit nobody wrote down is easy to let through. | Each limit is part of the model and every one is checked on every call. |
| Batten rules that change with batten width | Only with care The end-nail count and the spacing limit both depend on whether the batten is under 2.5 inches wide, so a rule is needed for each branch. | The requirement is derived from the batten width and compared with the plan. |
| Nail total at batten ends reconciled with the figure the order states | Only with workarounds A rules engine does not usually recompute a total from the plan and compare it with what the document says. | The total is computed from the plan and compared with the stated figure on every call. |
| Warranty cautions to be confirmed by a person (not blocked) | Only with workarounds A rules engine either allows or blocks; it has no way to say a person should confirm. | The case goes to a person with the reason, and is not guessed. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The order states 120 nails at batten ends; the plan gives 160. |
| 2 | The siding must be installed over wood structural panels of at least 7/16 category with an APA trademark (DOC PS 1 or PS 2), or LP FlameBlock fire-rated OSB sheathing. |
| 3 | LP SmartSide vertical siding shall not be installed horizontally. |
| 4 | Vertical siding or battens may span only one floor to ceiling or one floor to top of gable; do not bridge floors. |
| 5 | A properly installed water-resistive barrier is required behind the siding. |
| 6 | Fasteners must be hot-dip galvanized (ASTM A153) or equivalent corrosion resistant. |
| 7 | The siding must be fastened with ring shank nails. |
| 8 | The nail shank diameter is 91 thousandths of an inch; the minimum is 92 (0.092 inch). |
| 9 | The siding nail penetrates the sheathing by 5 mm; it must penetrate wood structural panel sheathing by at least 6 mm (1/4 inch). |
| 10 | The batten nail penetrates the siding by 5 mm; it must penetrate the vertical siding by at least 6 mm (1/4 inch). |
| 11 | Siding nails are spaced 7 inches on centre along the perimeter; the maximum is 6 inches. |
| 12 | Siding nails are placed 11 mm from ends and edges; the maximum is 10 mm (3/8 inch). |
| 13 | Batten nails are placed 11 mm from ends and edges; the maximum is 10 mm (3/8 inch). |
| 14 | The gap between vertical siding boards is 4 mm; the minimum is 5 mm (3/16 inch). |
| 15 | The batten is 37 mm wide and 13 mm thick; the minimum is 38 mm (1.5 inch) wide by 13 mm (0.5 inch) thick, actual size. |
| 16 | A batten narrower than 64 mm (2.5 inch) may not conceal the nail heads on the vertical siding, and visible nail heads are not covered by the LP warranty; a person should confirm. |
| 17 | The batten is 64 mm wide and 12 mm thick; the minimum is 38 mm (1.5 inch) wide by 13 mm (0.5 inch) thick, actual size. |
| 18 | 1 nails are planned at each end of a batten; this batten width needs at least 2. |
| 19 | Batten nails are spaced 13 inches on centre along alternating edges; the maximum for this batten width is 12. |
| 20 | Batten nails are spaced 25 inches on centre along alternating edges; the maximum for this batten width is 24. |
| 21 | Trim nails are used to fasten the battens; LP says ring shank nails should be used where negative wind loads are a concern, and detachment of battens is not covered by the limited warranty, so a person should confirm. |
| 22 | The siding is 9 mm from adjacent stucco, brick or cultured stone; the minimum is 10 mm (3/8 inch), sealed with sealant. |
| 23 | A multi-story wall needs a horizontal joint between floors flashed with sloped metal Z-flashing. |
| 24 | The space at the Z-flashing is 9 mm; the minimum is 10 mm (3/8 inch). |
| 25 | Siding nails are spaced 8 inches on centre along the perimeter; the maximum is 6 inches. |
| 26 | The order states 100 nails at batten ends; the plan gives 80. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please check a board and batten order for Hollis Ridge Builders: 48 battens, 2 nails at each end of each batten, siding nails every 8 inches and batten nails every 14 inches, a one-story wall. The order states 192 nails at batten ends in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please check a board and batten order for Hollis Ridge Builders: 48 battens, 2 nails at each end of each batten, siding nails every 6 inches and batten nails every 12 inches, a one-story wall. The order states 192 nails at batten ends in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please check a board and batten order for Hollis Ridge Builders: 60 battens, 2 nails at each end of each batten, siding nails every 6 inches and batten nails every 12 inches, a one-story wall. The order states 240 nails at batten ends in total. The sheathing is not 7/16 category panels and the water-resistive barrier is not included. It is ready to send.
Verdict: Blocked.
The agent's request. Please check a board and batten order for Hollis Ridge Builders: 60 battens, 2 nails at each end of each batten, siding nails every 6 inches and batten nails every 12 inches, a one-story wall. The order states 240 nails at batten ends in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please check a board and batten order for Hollis Ridge Builders: 36 battens, 2 nails at each end of each batten, siding nails every 6 inches and batten nails every 12 inches, a 2-story wall with no Z-flashing between floors, siding 6 mm from adjacent masonry. The order states 144 nails at batten ends in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please check a board and batten order for Hollis Ridge Builders: 36 battens, 2 nails at each end of each batten, siding nails every 6 inches and batten nails every 12 inches, a 2-story wall with Z-flashing, siding 10 mm from adjacent masonry. The order states 144 nails at batten ends in total. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.