Predictika · Air circuit breaker orders
An AI sales agent prepares an order for Susol AH air circuit breakers for a switchboard, with a frame, a rated current, a pole count and trip relay options. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published catalogue data and returns a verdict, every reason and the figures it computed.
This validator models orders for Susol AH air circuit breakers as listed in the public LS ELECTRIC catalogue, not just the scenarios shown below.
Any Susol AH breaker order that touches these rules is in scope — not only the scenarios pictured here. An operating voltage above 500 Vac goes to a person, because the breaking capacity used here is the catalogue figure at 500 Vac. Not covered: prices (LS ELECTRIC publishes no list prices, so this validator produces no price build-up or line-item quote), Metasol and other breaker series, the UL-listed range, other accessories, clearances between breakers, and switchboard design.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A rated current that the chosen frame does not offer | Only with care Each frame offers its own list of ratings, so every frame needs its own compatibility rule, kept in step with the catalogue by hand. | The frame and the rated current are in one request and compared on every call. |
| A short-circuit level above the frame's breaking capacity | Only with care A threshold per frame, usually a lookup table or a rule per frame that must be maintained as the catalogue changes. | The frame sets its own breaking capacity and the installation figure is compared with it on every call. |
| An option that only some trip relays accept | Only with workarounds The option and the trip relay sit on different lines, so it takes a cross-line rule, and a mismatch is often caught late or not at all. | Every item is in one request and each dependency is checked together with the rest. |
| Stated figures that disagree with the catalogue | Only with workarounds The figure the agent states is free text or a separate field, so it takes extra rules that recompute the catalogue value and compare. | The stated figures are part of the request and are compared with the computed ones on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote has a 2,500 ampere breaker in a frame that does not offer that rating; the catalogue lists D-frame 630 to 2,000 A, E-frame 630 to 4,000 A and G-frame 4,000 to 6,300 A. |
| 2 | The quote has a 3,200 ampere breaker in a frame that does not offer that rating; the catalogue lists D-frame 630 to 2,000 A, E-frame 630 to 4,000 A and G-frame 4,000 to 6,300 A. |
| 3 | The quote has a 4,000 ampere breaker in a frame that does not offer that rating; the catalogue lists D-frame 630 to 2,000 A, E-frame 630 to 4,000 A and G-frame 4,000 to 6,300 A. |
| 4 | The installation has a prospective short-circuit current of 90 kA; the selected frame breaks at most 85 kA at 500 Vac. |
| 5 | The installation has a prospective short-circuit current of 101 kA; the selected frame breaks at most 100 kA at 500 Vac. |
| 6 | The installation has a prospective short-circuit current of 151 kA; the selected frame breaks at most 150 kA at 500 Vac. |
| 7 | Zone selective interlocking (ZSI) is offered only with the A, P and S type trip relays; the quote has the N type. |
| 8 | The Profibus-DP module is offered only with the A, P and S type trip relays; the quote has the N type. |
| 9 | The quoted breakers are 668 mm wide in total by catalogue width; only 600 mm is available. |
| 10 | The quote states a breaking capacity of 100 kA, but the catalogue lists 85 kA at 500 Vac for the selected frame. |
| 11 | The quote states a total breaker width of 700 mm, but the catalogue widths add up to 668 mm. |
| 12 | The operating voltage is 690 V; the breaking capacity used here is the catalogue figure at 500 Vac, so a person should confirm the rating at this voltage. |
| 13 | The quote has 2 poles; the catalogue offers 3-pole and 4-pole breakers. |
| 14 | The quote has 0 breakers; an order needs at least one. |
| 15 | The installation has a prospective short-circuit current of 95 kA; the selected frame breaks at most 85 kA at 500 Vac. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote two E-frame Susol AH air circuit breakers rated 3,200 A, 3-pole, with the N type trip relay and zone selective interlocking and the Profibus-DP module, for a switchboard with 900 mm of width available and 80 kA of short-circuit current at the installation. The quote states a breaking capacity of 85 kA and a total breaker width of 824 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote two E-frame Susol AH air circuit breakers rated 3,200 A, 3-pole, with the P type trip relay and zone selective interlocking and the Profibus-DP module, for a switchboard with 900 mm of width available and 80 kA of short-circuit current at the installation. The quote states a breaking capacity of 100 kA and a total breaker width of 824 mm. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote three D-frame Susol AH air circuit breakers rated 2,500 A, 4-pole, with the A type trip relay, for a switchboard with 1,300 mm of width available and 95 kA of short-circuit current at the installation. The quote states a breaking capacity of 85 kA and a total breaker width of 1,257 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote three E-frame Susol AH air circuit breakers rated 2,500 A, 4-pole, with the A type trip relay, for a switchboard with 1,300 mm of width available and 95 kA of short-circuit current at the installation. The quote states a breaking capacity of 100 kA and a total breaker width of 1,581 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote three E-frame Susol AH air circuit breakers rated 2,500 A, 3-pole, with the A type trip relay, for a switchboard with 1,300 mm of width available and 95 kA of short-circuit current at the installation. The quote states a breaking capacity of 100 kA and a total breaker width of 1,236 mm. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote two G-frame Susol AH air circuit breakers rated 4,000 A, 4-pole, with the P type trip relay, for a switchboard with 1,800 mm of width available and 95 kA of short-circuit current at the installation. The quote states a breaking capacity of 150 kA and a total breaker width of 1,800 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote two G-frame Susol AH air circuit breakers rated 4,000 A, 3-pole, with the P type trip relay, for a switchboard with 1,800 mm of width available and 95 kA of short-circuit current at the installation. The quote states a breaking capacity of 150 kA and a total breaker width of 1,570 mm. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.