Predictika · Moulded case circuit breaker quotes
An AI sales agent prepares a quote for moulded case circuit breakers: a frame, a current rating, poles, a trip unit, a breaking capacity, accessories such as a motor operator or a voltage release, the site fault level and a discount. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the DN-Line frames and returns a verdict, every reason and the totals it computed.
This validator models DN-Line breaker quotes of this kind, not just the scenarios shown below.
Any DN-Line breaker quote that touches these rules is in scope — not only the scenarios pictured here. The DN-Line frame names, 3-pole and 4-pole breakers, thermal-magnetic release, IS/IEC 60947-2 and the 25 to 70 kA breaking-capacity classes come from public distributor and marketplace listings; the frame current ranges, the highest breaking capacity per frame, trip unit by frame, accessory compatibility, the fault-level margin, the ambient limit and the discount thresholds are modeled from comparable breaker families and are not published by Larsen & Toubro. No prices are modeled. Not covered: other L&T breaker ranges, air circuit breakers, protection relays, installation and taxes.
6 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A rating that must fit the frame chosen | Only with care Each of the four frames has its own current range, so every frame needs a rule that compares it with the rating, both above and below. | The frame and the rating are fields of one request and are checked together on every call. |
| A breaking capacity that depends on the frame and the site | Only with care The highest capacity differs by frame, and it must also exceed the site fault level, with a thin margin sent for review, so several figures are compared at once. | The frame, breaking capacity and fault level are in one request and checked together on every call. |
| Trip unit and accessory combinations | Only with care Electronic and thermal-magnetic trip units are limited by frame, a motor operator is not offered on one frame, and some accessories exclude each other, so each pair needs its own rule. | The frame, trip unit and every accessory are checked together on every call. |
| A stated total that must match the quoted breakers | Only with workarounds The total amperes come from the quantity times the rating, so a separate rule must recompute it and compare it with the stated figure. | The stated total is a field of the request and is compared with the computed total on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is saved or completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The rating is 125 A; the selected frame goes up to 100 A. |
| 2 | The rating is 320 A; the selected frame goes up to 250 A. |
| 3 | The rating is 100 A; the selected frame starts at 160 A. |
| 4 | The requested breaking capacity is 70 kA; the selected frame offers at most 50 kA. |
| 5 | The site fault level is 40 kA; the breaker breaking capacity is only 36 kA. |
| 6 | The site fault level of 36 kA is within 10 percent of the 36 kA breaking capacity; an engineer should confirm. |
| 7 | The site fault level of 33 kA is within 10 percent of the 36 kA breaking capacity; an engineer should confirm. |
| 8 | The selected trip unit is not offered on this frame (electronic from DN2 up, thermal-magnetic up to DN1). |
| 9 | The circuit has a switched neutral but the breaker is 3-pole. |
| 10 | A motor operator is not offered on the DN0 frame. |
| 11 | A shunt trip and an undervoltage release cannot both be fitted to one breaker. |
| 12 | A rotary handle and a motor operator cannot both be fitted. |
| 13 | The quote states 700 A in total; the quoted breakers give 800 A. |
| 14 | Ambient temperature of 55 C is above 45 C; the current rating may need derating, an engineer should confirm. |
| 15 | A discount of 20 percent is above 12 percent; a sales manager should approve it. |
| 16 | A discount of 30 percent is over the 25 percent limit. |
| 17 | The rating is 160 A; the selected frame goes up to 100 A. |
| 18 | The requested breaking capacity is 50 kA; the selected frame offers at most 36 kA. |
| 19 | The site fault level is 55 kA; the breaker breaking capacity is only 50 kA. |
| 20 | The quote states 100 A in total; the quoted breakers give 640 A. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote three 160 A breakers on the DN0 frame, 3-pole, electronic trip unit, with a breaking capacity of 50 kA, for a site fault level of 40 kA, with a shunt trip, an undervoltage release, a motor operator and a rotary handle, on a circuit with a switched neutral. The quote states 600 A in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote three 160 A breakers on the DN2 frame, 4-pole, electronic trip unit, with a breaking capacity of 50 kA, for a site fault level of 40 kA, with a shunt trip and a motor operator, on a circuit with a switched neutral. The quote states 480 A in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote four 320 A breakers on the DN1 frame, 3-pole, thermal-magnetic trip unit, with a breaking capacity of 70 kA, for a site fault level of 60 kA, at a discount of 30 percent. The quote states 1,280 A in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote four 320 A breakers on the DN2 frame, 3-pole, electronic trip unit, with a breaking capacity of 70 kA, for a site fault level of 60 kA, at a discount of 10 percent. The quote states 1,280 A in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote four 200 A breakers on the DN1 frame, 3-pole, thermal-magnetic trip unit, with a breaking capacity of 36 kA, for a site fault level of 40 kA, with a shunt trip. The quote states 700 A in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote four 200 A breakers on the DN1 frame, 3-pole, thermal-magnetic trip unit, with a breaking capacity of 50 kA, for a site fault level of 40 kA, with a shunt trip. The quote states 800 A in total. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.