An AI sales agent prepares a common DC bus for several frequency inverters, with the F1 semiconductor fuse, the supply and the wiring. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the manufacturer's published rules for interconnected operation and returns a verdict, every reason and the figures it computed.
This validator models a common DC bus of Lenze i550 cabinet frequency inverters (up to three drives per bus in this version), not just the scenarios shown below.
Any DC bus of these drives that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the document has none, so there is no price build-up or line-item quote), individual fuse protection of every unit (a different arrangement), DC buses with more than one infeed, UL motor-group fusing, other Lenze drive series and the cable cross-section tables, which the manufacturer leaves to the system designer.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| The smallest fuse limit among all drives on the bus sets the limit for the shared fuse | Only with care A roll-up of the minimum over a variable set of drives, held in a formula; every new drive size is another row to maintain. | Each drive's limit is looked up and the smallest is compared with the F1 rating on every call. |
| The B variants of the same size have a lower limit than the A variants | Only with care The limit depends on the full designation, not just the size, so it needs a lookup per designation, 29 of them here. | The limit is part of the model for each designation. |
| Fuse makers that list some ratings and not others | Only with care A table of five makers by eight ratings checked against the chosen fuse; easy to get wrong when a maker drops or adds a rating. | Maker and rating are checked against the listed types together. |
| Wiring rated for 122 percent of the AC-side fuse | Only with workarounds Two free-entry numbers compared by a formula that holds only when the AC fuse provides the overload protection; a product-rule engine has no natural place for it. | The comparison runs on every call, only when the AC fuse is the overload protection. |
| Short circuit rating, mains voltage and number of infeeds | Only with workarounds These are properties of the cabinet and the plant, not of the catalog, so a catalog-driven rule set has nowhere to hold them. | Plant figures travel with the design and are checked with the product choices. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so an engineer often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The F1 fuse is rated 80 A, but the drive with the smallest permitted fuse on this bus limits F1 to 50 A. |
| 2 | The quote states a maximum F1 fuse of 80 A; the fuse table gives 50 A for the drives on this bus. |
| 3 | The F1 fuse is rated 50 A, but the drive with the smallest permitted fuse on this bus limits F1 to 16 A. |
| 4 | The fuse table lists no SIBA semiconductor fuse of 350 A. |
| 5 | The fuse table lists no Littelfuse semiconductor fuse of 16 A. |
| 6 | The fuse table lists no Siemens semiconductor fuse of 40 A. |
| 7 | The F1 fuses in the DC feed must be 2-pole (+UG and -UG); this quote has 1 pole. |
| 8 | The short circuit current rating of the circuit may be 50 kA at most; this circuit is rated 65 kA. |
| 9 | The DC supply voltage must be generated from a rectified AC voltage of 480Y/277 V at most; the mains voltage is 500 V. |
| 10 | The permissible DC grid voltage range is 450 V to 750 V; this bus runs at 440 V. |
| 11 | The rated DC input currents are tabulated only at 565 V and 675 V; this bus runs at 440 V, so the currents must be confirmed with Lenze. |
| 12 | The permissible DC grid voltage range is 450 V to 750 V; this bus runs at 760 V. |
| 13 | The rated DC input currents are tabulated only at 565 V and 675 V; this bus runs at 760 V, so the currents must be confirmed with Lenze. |
| 14 | The rated DC input currents are tabulated only at 565 V and 675 V; this bus runs at 450 V, so the currents must be confirmed with Lenze. |
| 15 | The rated DC input currents are tabulated only at 565 V and 675 V; this bus runs at 600 V, so the currents must be confirmed with Lenze. |
| 16 | Overload protection by the AC-side fuse needs conductors rated for at least 122 percent of its rated current; the wiring is rated 60 A against a 50 A AC fuse. |
| 17 | Overload protection of the DC bus wiring by means other than the AC-side fuse is left to the system designer; the design must be reviewed. |
| 18 | The Lenze document covers a DC bus supplied by exactly one unit; this bus has 2 infeed units. Other topologies must be taken up with a Lenze representative. |
| 19 | The Lenze document covers a DC bus supplied by exactly one unit; this bus has 0 infeed units. Other topologies must be taken up with a Lenze representative. |
| 20 | The i550 terminals do not allow looping the DC potentials through, so several drives on one DC bus need an external DC distribution point in the control cabinet. |
| 21 | The quote states a maximum F1 fuse of 40 A; the fuse table gives 50 A for the drives on this bus. |
| 22 | The F1 fuse is rated 350 A, but the drive with the smallest permitted fuse on this bus limits F1 to 16 A. |
| 23 | The permissible DC grid voltage range is 450 V to 750 V; this bus runs at 800 V. |
| 24 | Overload protection by the AC-side fuse needs conductors rated for at least 122 percent of its rated current; the wiring is rated 40 A against a 40 A AC fuse. |
| 25 | The quote states a maximum F1 fuse of 350 A; the fuse table gives 16 A for the drives on this bus. |
| 26 | The rated DC input currents are tabulated only at 565 V and 675 V; this bus runs at 800 V, so the currents must be confirmed with Lenze. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a common DC bus for 3 Lenze i550 inverters (I55AE240F, I55AE230F and I55AE222F), with a 2-pole Siemens semiconductor fuse of 80 A at F1, overload protection by a 40 A AC-side fuse with DC bus wiring rated 60 A, fed by 1 infeed unit on a 400 V mains with a 565 V DC bus and a 50 kA short circuit rating, with an external DC distribution point. The quote states a maximum F1 fuse of 80 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a common DC bus for 3 Lenze i550 inverters (I55AE240F, I55AE230F and I55AE222F), with a 2-pole Siemens semiconductor fuse of 50 A at F1, overload protection by a 40 A AC-side fuse with DC bus wiring rated 60 A, fed by 1 infeed unit on a 400 V mains with a 565 V DC bus and a 50 kA short circuit rating, with an external DC distribution point. The quote states a maximum F1 fuse of 50 A. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a common DC bus for 3 Lenze i550 inverters (I55AE411F, I55AE390F and I55AE375F), with a 2-pole SIBA semiconductor fuse of 350 A at F1, overload protection by a 300 A AC-side fuse with DC bus wiring rated 400 A, fed by 1 infeed unit on a 480 V mains with a 700 V DC bus and a 65 kA short circuit rating, with an external DC distribution point. The quote states a maximum F1 fuse of 350 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a common DC bus for 3 Lenze i550 inverters (I55AE411F, I55AE390F and I55AE375F), with a 2-pole SIBA semiconductor fuse of 315 A at F1, overload protection by a 300 A AC-side fuse with DC bus wiring rated 400 A, fed by 1 infeed unit on a 480 V mains with a 700 V DC bus and a 50 kA short circuit rating, with an external DC distribution point. The quote states a maximum F1 fuse of 315 A. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a common DC bus for 3 Lenze i550 inverters (I55AE411F, I55AE390F and I55AE375F), with a 2-pole SIBA semiconductor fuse of 315 A at F1, overload protection by a 300 A AC-side fuse with DC bus wiring rated 400 A, fed by 1 infeed unit on a 480 V mains with a 675 V DC bus and a 50 kA short circuit rating, with an external DC distribution point. The quote states a maximum F1 fuse of 315 A. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a common DC bus for 3 Lenze i550 inverters (I55AE315F, I55AE318F and I55AE322F), with a 2-pole Mersen semiconductor fuse of 200 A at F1, overload protection by a 150 A AC-side fuse with DC bus wiring rated 200 A, fed by 2 infeed units on a 500 V mains with a 675 V DC bus and a 50 kA short circuit rating. The quote states a maximum F1 fuse of 200 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a common DC bus for 3 Lenze i550 inverters (I55AE315F, I55AE318F and I55AE322F), with a 2-pole Mersen semiconductor fuse of 200 A at F1, overload protection by a 150 A AC-side fuse with DC bus wiring rated 200 A, fed by 1 infeed unit on a 480 V mains with a 675 V DC bus and a 50 kA short circuit rating, with an external DC distribution point. The quote states a maximum F1 fuse of 200 A. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.