Predictika · Automotive blade fuse orders
An AI sales agent prepares an order for 32 V DC automotive blade fuses with the series, ampere rating, plating, package size, circuit voltage, available fault current, ambient temperature and the continuous load. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures in the public datasheets and returns a verdict, every reason and the figures it computed.
This validator models orders for three Littelfuse 32 V DC blade fuse series (ATOF 0287, MINI 0297 and MAXI 0299), not just the scenarios shown below.
Any order for these three series that touches these rules is in scope — not only the scenarios pictured here. Not covered: shunt versions, other Littelfuse fuse families, holders, wire and terminal effects, and prices (no public price list was used).
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A rating the series does not offer | Only with care A per-series list of valid ratings that has to be written and maintained for each series. | The series and the rating are in one request and checked on every call. |
| A load that is too high for the ambient temperature | Only with workarounds The limit comes from a two-way table of rating by temperature; it takes a lookup table or many formulas, kept for each series. | The load, rating, series and temperature are compared with the datasheet table on every call. |
| A plating and package combination that is not listed | Only with care Each series has its own ordering table, so each needs its own validation rule. | Series, plating and package size are checked together on every call. |
| A piece count that disagrees with packs times package size | Only with workarounds The count is a derived figure; checking a stated total against it takes extra formulas that interact with the rest. | The stated piece count is a field in the request and is compared with the computed one. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The continuous load is 14.5 A; the datasheet gives 14 A as the maximum load for this fuse at the ambient temperature. |
| 2 | The continuous load is 7.5 A; the datasheet gives 7 A as the maximum load for this fuse at the ambient temperature. |
| 3 | The ambient temperature of 126 degrees C is outside the datasheet derating table for this series. |
| 4 | The ambient temperature of -41 degrees C is outside the datasheet derating table for this series. |
| 5 | The continuous load is 15 A; the datasheet gives 14 A as the maximum load for this fuse at the ambient temperature. |
| 6 | The ATOF series is not listed in the 50 A rating. |
| 7 | The continuous load is 2 A; the datasheet gives 1.9 A as the maximum load for this fuse at the ambient temperature. |
| 8 | The ambient temperature of 101 degrees C is outside the datasheet derating table for this series. |
| 9 | The MINI series is not listed in the 1 A rating. |
| 10 | The MINI series is not listed in the 35 A rating. |
| 11 | The continuous load is 40 A; the datasheet gives 35 A as the maximum load for this fuse at the ambient temperature. |
| 12 | The MAXI series is not listed in the 10 A rating. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 20 packs of 10 tin plated Littelfuse MAXI blade fuses rated 60 A (200 pieces in all), for a 24 V DC circuit with a continuous load of 40 A, an ambient temperature of 110 degrees C and an available fault current of 800 A. The order states 100 pieces. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 20 packs of 10 tin plated Littelfuse MAXI blade fuses rated 80 A (200 pieces in all), for a 24 V DC circuit with a continuous load of 40 A, an ambient temperature of 110 degrees C and an available fault current of 800 A. The order states 200 pieces. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 20 packs of 10 silver plated Littelfuse MAXI blade fuses rated 80 A (200 pieces in all), for a 24 V DC circuit with a continuous load of 40 A, an ambient temperature of 110 degrees C and an available fault current of 800 A. The order states 200 pieces. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 20 packs of 500 tin plated Littelfuse ATOF blade fuses rated 20 A (10,000 pieces in all), for a 12 V DC circuit with a continuous load of 17 A, an ambient temperature of 85 degrees C and an available fault current of 600 A. The order states 10,000 pieces. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 20 packs of 500 tin plated Littelfuse ATOF blade fuses rated 25 A (10,000 pieces in all), for a 12 V DC circuit with a continuous load of 17 A, an ambient temperature of 85 degrees C and an available fault current of 600 A. The order states 10,000 pieces. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 10 packs of 500 silver plated Littelfuse MINI blade fuses rated 15 A (5,000 pieces in all), for a 48 V DC circuit with a continuous load of 8 A, an ambient temperature of 40 degrees C and an available fault current of 2,000 A. The order states 5,000 pieces. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 10 packs of 500 silver plated Littelfuse MINI blade fuses rated 15 A (5,000 pieces in all), for a 24 V DC circuit with a continuous load of 8 A, an ambient temperature of 40 degrees C and an available fault current of 800 A. The order states 5,000 pieces. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.