Predictika · Automotive blade fuse orders
An AI sales agent prepares an order for MINI 32V automotive blade fuses: the current rating, the ambient temperature, the circuit voltage and fault current, the plating and the packs. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures in the published datasheet and returns a verdict, every reason and the figures it computed.
This validator models orders for the MINI series 32V automotive blade fuses in the public datasheet, not just the scenarios shown below.
Any MINI 32V fuse order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (no public price list was found, so this validator produces no price build-up or line-item quote), the SHUNT part, other Littelfuse fuse series, terminal and wire sizing, time-current (opening time) selection, and temperatures between the datasheet's columns, which are sent to a person. Assumption: the quantity is ordered in whole packs.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A load that must stay under a temperature-derated current | Only with care A table of 80 values (rating by temperature) has to be kept as rules or a lookup, and each fuse line has to be compared with the ambient temperature set elsewhere on the order. | The rating and the ambient temperature are in one request and the load is compared with the datasheet table on every call. |
| Plating that decides whether UL recognition is available | Only with care A compatibility rule between the approvals requirement and the plating of the chosen pack, repeated for every pack. | The requirement and the pack are in one request and checked together. |
| A stated allowed current that disagrees with the datasheet | Only with workarounds The figure the agent states is a free-entry field, so it takes an extra rule that recomputes the derated current from two other fields. | The stated figure travels with the order and is compared with the table value on every call. |
| A temperature between the datasheet columns | Only with workarounds A table lookup has no value between columns, and a rule must decide whether to round, interpolate or stop for a person. | The order is sent to approval with a plain-English reason instead of guessing a figure. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The continuous load of 1.9 A is above the 1.9 A the datasheet allows for this fuse rating at this ambient temperature. |
| 2 | The continuous load of 30.0 A is above the 30 A the datasheet allows for this fuse rating at this ambient temperature. |
| 3 | The continuous load of 9.8 A is above the 9.8 A the datasheet allows for this fuse rating at this ambient temperature. |
| 4 | The continuous load of 9.0 A is above the 9 A the datasheet allows for this fuse rating at this ambient temperature. |
| 5 | UL recognition is required, but the tin-plated version is not UL recognized; the silver-plated versions comply with UL 248. |
| 6 | The circuit runs at 33 V DC; the fuse is rated 32 V DC. |
| 7 | The available fault current is 1,001 A; the interrupting rating is 1,000 A at 32 V DC. |
| 8 | The datasheet derating table lists only -40, -20, 0, 20, 40, 60, 80 and 100 degrees C; a person should confirm the allowed current at 125 degrees C. |
| 9 | The ambient temperature of 126 degrees C is outside the operating range of -40 to 125 degrees C. |
| 10 | The ambient temperature of -41 degrees C is outside the operating range of -40 to 125 degrees C. |
| 11 | The datasheet derating table lists only -40, -20, 0, 20, 40, 60, 80 and 100 degrees C; a person should confirm the allowed current at 30 degrees C. |
| 12 | The order has 0 packs; at least 1 pack is needed. |
| 13 | The quote states 2,001 fuses; the packs ordered make 2,000 fuses. |
| 14 | The quote states 1,500 fuses; the packs ordered make 2,000 fuses. |
| 15 | The quote states an allowed current of 13 A; the datasheet derating table gives 12 A. |
| 16 | The quote states 1,000 fuses; the packs ordered make 2,000 fuses. |
| 17 | The continuous load of 12.0 A is above the 12 A the datasheet allows for this fuse rating at this ambient temperature. |
| 18 | The circuit runs at 48 V DC; the fuse is rated 32 V DC. |
| 19 | The available fault current is 3,000 A; the interrupting rating is 1,000 A at 32 V DC. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 3,000 MINI 32V blade fuses (20 A rating, tin-plated, 3,000 per pack (suffix .WXT)), 1 pack, for a circuit in an 80 degree C compartment that carries 15 A continuously on 24 V DC with up to 900 A of available fault current, where UL recognition is required. The quote states 3,000 fuses and an allowed continuous current of 20 A at that temperature. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 3,000 MINI 32V blade fuses (25 A rating, silver-plated, 500 per pack (suffix .U)), 6 packs, for a circuit in an 80 degree C compartment that carries 15 A continuously on 24 V DC with up to 900 A of available fault current, where UL recognition is required. The quote states 3,000 fuses and an allowed continuous current of 17 A at that temperature. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 3,000 MINI 32V blade fuses (30 A rating, silver-plated, 100 per pack (suffix .H)), 30 packs, for a circuit in a 100 degree C compartment that carries 20 A continuously on 48 V DC with up to 3,000 A of available fault current. The quote states 3,000 fuses. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 3,000 MINI 32V blade fuses (30 A rating, silver-plated, 100 per pack (suffix .H)), 30 packs, for a circuit in a 90 degree C compartment that carries 17 A continuously on 32 V DC with up to 1,000 A of available fault current. The quote states 3,000 fuses. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 3,000 MINI 32V blade fuses (30 A rating, silver-plated, 100 per pack (suffix .H)), 30 packs, for a circuit in a 100 degree C compartment that carries 18 A continuously on 32 V DC with up to 1,000 A of available fault current. The quote states 3,000 fuses and an allowed continuous current of 18 A at that temperature. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 2,000 MINI 32V blade fuses (10 A rating, silver-plated, 50 per pack (suffix .L)), 40 packs, for a circuit in a 40 degree C compartment that carries 8.6 A continuously on 12 V DC with up to 500 A of available fault current. The quote states 2,500 fuses and an allowed continuous current of 9 A at that temperature. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2,000 MINI 32V blade fuses (10 A rating, silver-plated, 50 per pack (suffix .L)), 40 packs, for a circuit in a 40 degree C compartment that carries 8.6 A continuously on 12 V DC with up to 500 A of available fault current. The quote states 2,000 fuses and an allowed continuous current of 8.6 A at that temperature. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.