Predictika · V-shape liquid cooler orders
An AI sales agent prepares an order for a V-shape liquid (dry) cooler: a cooler family, the number and diameter of fans, the motor type and options, a switchboard and controller, the fluid and pressure, the duty and the capacity it states in kilowatts. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the order rules and returns a verdict, every reason and the capacity it computed.
This validator models V-shape liquid cooler orders of this kind, not just the scenarios shown below.
Any V-shape liquid cooler order that touches these rules is in scope — not only the scenarios pictured here. Family names, fan diameters, family capacity ranges and option names follow public Lu-Ve product pages; the capacity per fan, which options each family offers, the switchboard and controller dependencies and the review thresholds are modeled and not published by Lu-Ve. No prices are modeled. Not covered: air-cooled condensers, CO2 gas coolers, other Lu-Ve families, accessories and selection software results.
6 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Options that depend on the cooler family | Only with care Each family offers different fan diameters, motors and options, so every option needs a rule on the family it is ordered with. | The family and every option are fields of one request and are checked together on every call. |
| Options that depend on each other | Only with care The switchboard needs EC motors, the controller needs a switchboard and the Aluplus coating excludes copper fins, so each pair needs its own rule. | All the dependencies between options are checked together on every call. |
| A capacity that depends on fans, diameter and coil | Only with workarounds The capacity is the fan count times a figure that depends on the fan diameter and the coil depth, so it must be computed before the duty can be compared with it. | The capacity is computed on every call and compared with the duty and with the capacity stated in the order. |
| Review thresholds on duty and pressure | Only with workarounds A duty close to the capacity, an oversized cooler and a higher pressure each need a separate review rule beside the blocking rules. | The thresholds are rules in the same model, so a person is asked to review only when no blocking finding applies. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is saved or completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the order; approval findings need a person to sign off; everything else is computed.
| 1 | 3 fans is outside the range offered for this cooler family (4 to 20 fans). |
| 2 | The capacity is more than twice the duty; a person should confirm the sizing. |
| 3 | 7 fans is outside the range offered for this cooler family (2 to 6 fans). |
| 4 | This fan diameter is not offered on the selected cooler family. |
| 5 | This cooler family is supplied with EC fan motors only. |
| 6 | The Whisperer low-noise and radial motor options are offered on Giant S only. |
| 7 | The Whisperer and radial motor options need EC fan motors. |
| 8 | The Adiabatic System is not offered on Giant S Tower. |
| 9 | The Aluplus coating is for aluminium fins; it cannot be ordered with copper fins. |
| 10 | Copper fins are a special build; a person should confirm availability. |
| 11 | The ECCB and ECCB+MC switchboards are for EC fan motors. |
| 12 | A master controller needs a switchboard. |
| 13 | The coil is copper tube; fluids that corrode copper are not allowed. |
| 14 | 12 bar is above the 10 bar design pressure. |
| 15 | Operating pressure is above 6 bar; a person should confirm the pressure equipment documentation. |
| 16 | 2,700 kW is above the largest capacity of this family (2,670 kW). |
| 17 | The duty needs 400 kW; this configuration gives 380 kW. |
| 18 | The duty is above 90 percent of the capacity; a person should confirm the design conditions. |
| 19 | The order states 400 kW; the configuration computes to 380 kW. |
| 20 | 11 fans is outside the range offered for this cooler family (1 to 10 fans). |
| 21 | The duty needs 2,000 kW; this configuration gives 1,155 kW. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a Giant S Tower cooler with 6 fans of 960 mm, EC motors and a 4-row coil with copper fins, with the Whisperer option, the Adiabatic System and the Aluplus coating, a Ptec controller. The fluid is glycol at 6 bar and the duty is 500 kilowatts. The order states a capacity of 630 kilowatts. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Giant S cooler with 6 fans of 960 mm, EC motors and a 4-row coil with aluminium fins, with the Whisperer option, the Adiabatic System and the Aluplus coating, an ESB switchboard and a Ptec controller. The fluid is glycol at 6 bar and the duty is 500 kilowatts. The order states a capacity of 630 kilowatts. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote an Alfa V Mega Jumbo cooler with 3 fans of 910 mm, AC motors and a 4-row coil with aluminium fins, with radial motors, an ECCB switchboard. The fluid is glycol at 6 bar and the duty is 250 kilowatts. The order states a capacity of 285 kilowatts. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote an Alfa V Mega Jumbo cooler with 4 fans of 910 mm, EC motors and a 4-row coil with aluminium fins, an ECCB switchboard. The fluid is glycol at 6 bar and the duty is 250 kilowatts. The order states a capacity of 380 kilowatts. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Giant S Tower cooler with 4 fans of 910 mm, EC motors and a 4-row coil with aluminium fins. The fluid is a fluid that corrodes copper at 12 bar and the duty is 400 kilowatts. The order states a capacity of 400 kilowatts. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Giant S Tower cooler with 4 fans of 910 mm, EC motors and a 4-row coil with aluminium fins. The fluid is glycol at 6 bar and the duty is 300 kilowatts. The order states a capacity of 380 kilowatts. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.