Predictika · Two-component dispensing
An AI sales agent prepares an order for a two-component adhesive line: MIXPAC C-System cartridges (200 or 400 mL, in a given mixing ratio), the static mixers that go with them and a manual or battery dispenser, with the mixer elements and waste volume the customer asks for and the total mixer waste volume it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the compatibility tables in the public medmix MIXPAC brochure and returns a verdict, every reason and the figures it computed.
This validator models an order built from the MIXPAC C-System in the public medmix brochure “MIXPAC Systems for Adhesives”, not just the scenarios shown below.
Any order built from these C-System cartridges, mixers and dispensers is in scope — not only the scenarios pictured here. Not covered: the 200 mL 4:1 cartridge (AC 200-04-10-04), because the brochure's cartridge matrix and mixer table disagree about which mixers fit it, prices (medmix publishes no list prices, so this page shows no price build-up), the A, B, F, K and Blueline systems, the DP2X pneumatic dispenser (its row in the brochure table could not be read unambiguously), the MGH mixer series (listed against cartridges but without articles in the mixer table), outlet tips and accessories, machine mixers, and whether an adhesive suits a given mixer.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Only the cartridge, mixer series and ratio combinations the brochure lists | Only with workarounds Which mixer series fit depends on the cartridge volume, ratio and, for one 10:1 400 mL article, the article itself, so a rules-based CPQ needs a compatibility table or a rule per cartridge, and every brochure update means editing them. | Cartridge and mixer arrive in one request and are matched to the published rows on every call. |
| Dispenser that covers the ratio, and the battery dispenser only for 400 mL | Only with care A dispenser model is tied to the ratios it covers and to the cartridge volume; it is two more table lookups that depend on the cartridge chosen earlier. | The dispenser, the ratio and the volume are compared together, in any order. |
| Mixer elements and waste volume against what the customer asks for | Only with care The element count and waste volume belong to the mixer article, so a rule has to look them up before it can compare them with the customer's limits. | Both limits are compared with the chosen mixer's published values on every call. |
| Total waste volume the order states | Only with care The stated total is derived from the mixer article and the quantity, so a rule has to recompute it and compare. | The stated total is a field in the request, compared with the computed one on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The selected mixer series is not listed as a match for this cartridge; the brochure lists the matching mixer series for each cartridge by volume and mixing ratio. |
| 2 | The order needs at least 24 mixing elements; the selected mixer has 18. |
| 3 | The selected dispenser does not cover the 1:1 mixing ratio of this cartridge. |
| 4 | The selected dispenser does not cover the 2:1 mixing ratio of this cartridge. |
| 5 | The battery dispenser is listed only for 400 mL cartridges; this cartridge holds 200 mL. |
| 6 | The order allows 14,599 microliters of waste volume in each mixer; the selected mixer holds 14,600. |
| 7 | The order allows 20,000 microliters of waste volume in each mixer; the selected mixer holds 27,300. |
| 8 | The order has 0 cartridges; at least 1 is needed. |
| 9 | The order has 0 mixers; at least 1 is needed. |
| 10 | The order states 1,450,000 microliters of waste volume across all mixers; the brochure values give 1,460,000. |
| 11 | The order states 1,460,001 microliters of waste volume across all mixers; the brochure values give 1,460,000. |
| 12 | The selected dispenser does not cover the 10:1 mixing ratio of this cartridge. |
| 13 | The order states 5 microliters of waste volume across all mixers; the brochure values give 1,404,000. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 600 MIXPAC C-System cartridges, AC 400-10-10-01 (400 mL, 10:1), with 800 MGQ 10-24D static mixers and the DM2X 400-10-60 manual dispenser. The mixers need at least 18 mixing elements and may hold no more than 20,000 microliters of waste volume each. The order states 11,592,000 microliters of waste volume across all mixers in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 600 MIXPAC C-System cartridges, AC 400-10-10-01 (400 mL, 10:1), with 800 MCHX 10-24T static mixers and the DM2X 400-10-60 manual dispenser. The mixers need at least 18 mixing elements and may hold no more than 20,000 microliters of waste volume each. The order states 12,960,000 microliters of waste volume across all mixers in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1,500 MIXPAC C-System cartridges, AC 400-02-10-04 (400 mL, 2:1), with 1,800 MCQ 10-32T static mixers and the DB2K 400-01-500 battery dispenser. The mixers need at least 24 mixing elements and may hold no more than 20,000 microliters of waste volume each. The order states 36,000,000 microliters of waste volume across all mixers in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1,500 MIXPAC C-System cartridges, AC 400-02-10-04 (400 mL, 2:1), with 1,800 MCQ 10-32T static mixers and the DB2K 400-02-500 battery dispenser. The mixers need at least 24 mixing elements and may hold no more than 20,000 microliters of waste volume each. The order states 33,210,000 microliters of waste volume across all mixers in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 900 MIXPAC C-System cartridges, AC 200-10-10-02 (200 mL, 10:1), with 1,000 MCQ 10-24T-01 static mixers and the DM2X 400-10-60 manual dispenser. The mixers need at least 18 mixing elements and may hold no more than 20,000 microliters of waste volume each. The order states 14,040,000 microliters of waste volume across all mixers in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 900 MIXPAC C-System cartridges, AC 200-10-10-02 (200 mL, 10:1), with 1,000 MCHX 10-24T static mixers and the DM2X 400-10-60 manual dispenser. The mixers need at least 18 mixing elements and may hold no more than 20,000 microliters of waste volume each. The order states 16,200,000 microliters of waste volume across all mixers in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 900 MIXPAC C-System cartridges, AC 200-10-10-02 (200 mL, 10:1), with 1,000 MCHX 10-24T static mixers and the DB2K 400-10-500 battery dispenser. The mixers need at least 18 mixing elements and may hold no more than 20,000 microliters of waste volume each. The order states 16,200,000 microliters of waste volume across all mixers in total. It is ready to send.
Verdict: Blocked.
The text of the narrated walkthrough, step by step.