An AI sales agent prepares a quote for foil strain gages for a customer's test: the gage series and option, the temperature range, the expected strain, the adhesive, the protective coating, the S-T-C number for the test material, the data acquisition instrument and the temperature rating the quote states for the series. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the Micro-Measurements Strain Gage Sensor Reference Guide and returns a verdict, each finding and the reason.
This validator models a quote for one foil strain gage selection, based on the tables in the public Micro-Measurements Strain Gage Sensor Reference Guide (document 8690-EN, May 2020), not just the scenarios shown below.
Any foil strain gage quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the guide has none, so this page shows no price build-up), series the model leaves out (such as J2A, J5K, TA, TK, RK and ZC), gage patterns and resistances other than the 5000 ohm bridge rule, free-filament gages and cements, and installation procedures.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Strain limit that depends on gage length | Only with care The limit is 3 percent below 1/8 inch and 5 percent at 1/8 inch and over for the EA and CEA, but different for other series, so the quote has to be compared with the right figure. | The series and gage length are looked up together on every call and compared with the strain in the quote. |
| Temperature ranges with a special or short-term extension | Only with workarounds A series can be used in a wider range only for special or short-term use, and options narrow the range again, so one range is not enough. | Normal range, special range and option limits are checked together, and the answer says which one the quote breaks. |
| Adhesive advice by test type and temperature | Only with workarounds Recommendations depend on the series, the type of test and the temperature range, and some ranges overlap, so a simple product rule is either too strict or silent. | The rows that apply are found for the quote, and an adhesive outside them is flagged for a person. |
| Instrument limits on rate, channels and test type | Only with care Each instrument has its own highest data rate and channel count, and is listed for either constant-load or varying-load tests. | Rate, channels and test type are compared with the instrument together, in any order the choices arrive. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The guide gives no adhesive recommendation for the CEA series in static stress analysis use over 70 to 350 F; a person must choose the adhesive. |
| 2 | An operating range of 70 to 351 F is outside the widest range the guide gives for the CEA series, -100 to 350 F. |
| 3 | The guide gives no adhesive recommendation for the CEA series in static stress analysis use over 70 to 351 F; a person must choose the adhesive. |
| 4 | Stacked rosettes of the CEA series are limited to +150 F and the quote operates up to 151 F. |
| 5 | The guide gives no adhesive recommendation for the CEA series in static stress analysis use over 70 to 151 F; a person must choose the adhesive. |
| 6 | An operating range of 70 to 400 F is beyond the normal range of the EA series (-100 to 350 F); the guide allows that only for special or short-term use, so a person should confirm the duration. |
| 7 | The guide gives no adhesive recommendation for the EA series in static stress analysis use over 70 to 400 F; a person must choose the adhesive. |
| 8 | An operating range of 70 to 400 F is beyond the normal range of the EA series (-100 to 350 F); the guide allows that only for special or short-term use, and the quote does not say short-term. |
| 9 | An operating range of 70 to 401 F is outside the widest range the guide gives for the EA series, -320 to 400 F. |
| 10 | The guide gives no adhesive recommendation for the EA series in static stress analysis use over 70 to 401 F; a person must choose the adhesive. |
| 11 | An operating range of -320 to 150 F is beyond the normal range of the EA series (-100 to 350 F); the guide allows that only for special or short-term use, so a person should confirm the duration. |
| 12 | The guide gives no adhesive recommendation for the EA series in static stress analysis use over -320 to 150 F; a person must choose the adhesive. |
| 13 | An operating range of -101 to 150 F is outside the widest range the guide gives for the CEA series, -100 to 350 F. |
| 14 | The guide gives no adhesive recommendation for the CEA series in static stress analysis use over -101 to 150 F; a person must choose the adhesive. |
| 15 | The expected strain of 50,001 microstrain is above the 50,000 microstrain the guide gives for the CEA series at a gage length of 125 mils. |
| 16 | The expected strain of 30,001 microstrain is above the 30,000 microstrain the guide gives for the CEA series at a gage length of 62 mils. |
| 17 | The expected strain of 150,000 microstrain is above the 100,000 microstrain the guide gives for the EP series at a gage length of 62 mils. |
| 18 | Option W on an EP gage may reduce the large post-yield strain range the series is chosen for; a person should confirm. |
| 19 | The ED series is nonlinear above 5,000 microstrain and the quote expects 10,000 microstrain; a person should confirm it suits the measurement. |
| 20 | The expected strain of 21,000 microstrain is above the 20,000 microstrain the guide gives for the ED series at a gage length of 125 mils. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote WD strain gages with a gage length of 125 mils for dynamic (cyclic) stress analysis on carbon steel (S-T-C number 6), bonded with M-Bond AE-10 and protected with M-Coat A for use in a laboratory at 50 percent relative humidity or lower. The test runs from 70 to 100 F with an expected strain of 3,000 microstrain. Readings are taken with the instrument 8000 at 1,500 samples per second on 140 channels. The quote says the WD series is rated to 500 F in normal use. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote WD strain gages with a gage length of 125 mils for dynamic (cyclic) stress analysis on carbon steel (S-T-C number 6), bonded with M-Bond AE-10 and protected with M-Coat A for use in a laboratory at 50 percent relative humidity or lower. The test runs from 70 to 100 F with an expected strain of 3,000 microstrain. Readings are taken with the instrument 9000 at 1,500 samples per second on 40 channels. The quote says the WD series is rated to 500 F in normal use. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote CEA strain gages with a gage length of 62 mils for static stress analysis on carbon steel (S-T-C number 6), bonded with M-Bond 200 and protected with M-Coat A for use in a laboratory at 50 percent relative humidity or lower. The test runs from 70 to 150 F with an expected strain of 35,000 microstrain. The quote says the CEA series is rated to 400 F in normal use. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote CEA strain gages with a gage length of 125 mils for static stress analysis on carbon steel (S-T-C number 6), bonded with M-Bond 200 and protected with M-Coat A for use in a laboratory at 50 percent relative humidity or lower. The test runs from 70 to 150 F with an expected strain of 35,000 microstrain. The quote says the CEA series is rated to 350 F in normal use. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote EA strain gages with a gage length of 125 mils and Option P2 for static stress analysis on aluminum (S-T-C number 6), bonded with M-Bond 200 and protected with M-Coat W-1 Wax for use in long-term salt water immersion. The test runs from 70 to 150 F with an expected strain of 2,000 microstrain. The quote says the EA series is rated to 350 F in normal use. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote EA strain gages with a gage length of 125 mils for static stress analysis on aluminum (S-T-C number 6), bonded with M-Bond 200 and protected with M-Coat W-1 Wax for use in long-term salt water immersion. The test runs from 70 to 150 F with an expected strain of 2,000 microstrain. The quote says the EA series is rated to 350 F in normal use. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote EA strain gages with a gage length of 125 mils for static stress analysis on aluminum (S-T-C number 13), bonded with M-Bond 200 and protected with M-Coat W-1 Wax combined with M-Coat JA for use in long-term salt water immersion. The test runs from 70 to 150 F with an expected strain of 2,000 microstrain. The quote says the EA series is rated to 350 F in normal use. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.