Predictika · Radiation monitoring configurations
An AI sales agent prepares a configuration for a personnel contamination monitor with a detector type, a door or barrier, small item monitors, a frisker, calibration and gamma options and accessories. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published ordering notes and returns a verdict and every reason.
This validator models Argos-3 and Argos-5 configurations as described in the public Mirion Contamination Monitor Configuration Guide (read October 6, 2026), not just the scenarios shown below.
Any Argos-3 or Argos-5 configuration that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the guide gives none, so this validator produces no price build-up), the Sirius-5, GEM-5 and Cronos monitors, software and database options, shielding for other monitors, and the detector counts per model.
8 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Options built for specific detector types | Only with care A product rule per option and detector type; it works, but each new option adds rules that must be kept in step with the guide. | The detector type and every option are in one request and each compatibility is checked on every call. |
| Parts that must come together, such as a lead kit with a gamma option | Only with care A requires rule per pairing, and the exception when Zeus is ordered at the same time adds another condition. | The monitor, the gamma option, the door or barrier and both curtain kits are compared together on every call. |
| Options that exclude each other on the same side | Only with workarounds Exclusions that depend on which side of the monitor an item is on need extra attributes and rules that interact with each other. | All the entrance-side choices are in one request and the conflicts are returned together. |
| A customer ID card to confirm before a reader is ordered | Only with workarounds A recommendation that depends on a step outside the quote is usually left to a manual check. | A reader with no sample recorded comes back as an item for a person to confirm, in the same answer. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the configuration is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The chosen small item monitor is built for a different detector type than the one on this Argos monitor. |
| 2 | A side-mounted small item monitor is mutually exclusive with entrance doors. |
| 3 | The side-mount second display and keyboard kit is mutually exclusive on the same side with a sliding door, a frisker or a side-mounted small item monitor. |
| 4 | The chosen frisker is built for a different detector type than the one on this Argos monitor. |
| 5 | The gas regulators are for the gas-flow AB monitors only. |
| 6 | The chosen calibration fixture is for a different detector type; the LFP fixture is for AB monitors and the TPS fixture for the PB, PAB and PBG monitors. |
| 7 | The moveable head detector type does not match the monitor; the gas-flow one is for AB monitors and the gasless one for PB, PAB and PBG monitors. |
| 8 | An Argos-3 with a moveable head detector needs an additional head detector of the same type as the rest of the system. |
| 9 | The PBG monitors and the Zeus gamma option require the CURTAINPB front curtain lead kit. |
| 10 | A sliding door or an electric barrier needs the 816614 front curtain unless the Zeus gamma option is ordered at the same time. |
| 11 | The AccuRate-PBG options are for the PBG monitors only. |
| 12 | The AccuRate-ZEUS options need the Zeus gamma option and are for the AB, PB and PAB monitors, not the PBG. |
| 13 | The AccuRate moveable head versions need a moveable head detector ordered at the same time. |
| 14 | The floor mounting kit comes with the note to consult the factory for seismic analysis, so a person should confirm it before the quote goes out. |
| 15 | Mirion recommends sending a sample of the customer ID card to the factory to confirm reader compatibility, and no sample is recorded, so a person should confirm it. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please configure an Argos-5PBG personnel contamination monitor with an entrance sliding door (817007), a side-mounted beta/gamma small item monitor (Argos-SIMPBG) and the side-mount second display and keyboard kit (7063217). It is ready to send.
Verdict: Blocked.
The agent's request. Please configure an Argos-5PBG personnel contamination monitor with an exit sliding door (817008), a side-mounted beta/gamma small item monitor (Argos-SIMPBG), the CURTAINPB front curtain lead kit and the 816614 front curtain. It is ready to send.
Verdict: Allowed.
The agent's request. Please configure an Argos-5AB personnel contamination monitor with a beta smart-probe frisker (ARGOS5-FSKPB), the TPS calibration fixture (CAL-FIXTURE-TPS), the Zeus-5G gamma option and AccuRate-ZEUS anthropometric correction. It is ready to send.
Verdict: Blocked.
The agent's request. Please configure an Argos-5AB personnel contamination monitor with a gas-flow frisker (ARGOS-FSK5), the LFP calibration fixture (CAL-FIXTURE-LFP), the Zeus-5G gamma option and AccuRate-ZEUS anthropometric correction. It is ready to send.
Verdict: Blocked.
The agent's request. Please configure an Argos-5AB personnel contamination monitor with a gas-flow frisker (ARGOS-FSK5), the LFP calibration fixture (CAL-FIXTURE-LFP), the Zeus-5G gamma option, AccuRate-ZEUS anthropometric correction and the CURTAINPB front curtain lead kit. It is ready to send.
Verdict: Allowed.
The agent's request. Please configure an Argos-3PB personnel contamination monitor with an entrance electric barrier (816651), a gasless moveable head detector (Argos5-TPS-MHD-XTD), AccuRate-PBG-MHD anthropometric correction and a floor mounting kit. It is ready to send.
Verdict: Blocked.
The agent's request. Please configure an Argos-3PB personnel contamination monitor with an entrance electric barrier (816651), a gasless moveable head detector (Argos5-TPS-MHD-XTD), an additional head detector of the same type as the rest of the system, the 816614 front curtain and a floor mounting kit. It is ready to send.
Verdict: Needs approval.
The agent's request. Please configure an Argos-3PB personnel contamination monitor with an entrance electric barrier (816651), a gasless moveable head detector (Argos5-TPS-MHD-XTD), an additional head detector of the same type as the rest of the system and the 816614 front curtain. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.