Predictika · Data center cooling equipment orders
An AI sales agent prepares an order for indirect evaporative cooling units for a data center, with the model, mounting, supplemental cooling and site limits. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published product sheet and returns a verdict, every reason and the figures it computed.
This validator models orders for the Munters Oasis Standard indirect air-side economizer with indirect evaporative cooling, not just the scenarios shown below.
Any Oasis Standard order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Munters does not publish prices, so this validator produces no price build-up or line-item quote), the capacity at a given delta T or altitude (the sheet gives only the maximum), other options on the sheet (controls, dampers, fans, coatings, mirror access, transfer switch), other Munters products, and installation or service.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A rating that depends on conditions and a load right at the limit | Only with care A hard limit is easy to enforce, but a load exactly at the limit needs its own rule that routes to a person, and that is easy to leave out. | The load is compared with the rating on every call, and a load at the rating is routed to an engineer. |
| Stated totals that must equal what the quoted units give | Only with care A stated figure is a free-entry field; a rule can compare it with a computed total, but each model needs its own lookup that has to be kept in step with the sheet. | The stated capacity and airflow travel with the quote and are compared with the computed totals. |
| Height and weight that change with the mounting | Only with workarounds The same model has different height and operating weight on a roof and on a perimeter mount, and each has to be compared with a different site limit; that is a calculation, not an option rule. | Height and weight are looked up from the model and the mounting and compared with the site limits together. |
| A footprint that must fit the pad in both directions | Only with workarounds A length and a width that depend on the model are compared with two site dimensions, which takes several linked rules. | The unit dimensions come from the model and both pad dimensions are checked in the same call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The design load is 191 kW per unit, but this model is rated for up to 190 kW. |
| 2 | The design load of 190 kW per unit equals the maximum rating, which depends on delta T and altitude, so an engineer must confirm it at the design conditions. |
| 3 | The design airflow is 60,001 CFM per unit, but this model is rated for up to 60,000 CFM. |
| 4 | The unit footprint is 300 x 98 inches, but the available pad is 299 x 110 inches. |
| 5 | The unit footprint is 300 x 140 inches, but the available pad is 320 x 139 inches. |
| 6 | The unit is 186.5 inches tall including the scavenger fan intake plenum, but the site allows 180 inches. |
| 7 | The unit is 225 inches tall including the scavenger fan intake plenum, but the site allows 200 inches. |
| 8 | The approximate operating weight is 19,300 lb per unit, but the support is limited to 19,000 lb. |
| 9 | The approximate operating weight is 35,000 lb per unit, but the support is limited to 34,000 lb. |
| 10 | The quote states 400 kW of cooling in total; the quoted units are rated for up to 500 kW in total. |
| 11 | The quote states 70,000 CFM of airflow in total; the quoted units are rated for up to 80,000 CFM in total. |
| 12 | The design load of 250 kW per unit equals the maximum rating, which depends on delta T and altitude, so an engineer must confirm it at the design conditions. |
| 13 | The design conditions are extreme and the quote has no trim DX or chilled water supplemental cooling, which the product sheet offers for extreme conditions; an engineer must confirm the unit can carry the load. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote two Munters Oasis 60 indirect evaporative cooling units on a perimeter mount, each for a design load of 360 kW and 55,000 CFM, on a pad of 310 by 130 inches, with a height limit of 200 inches and a support limit of 26,000 lb per unit. The quote states 750 kW and 120,000 CFM in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote two Munters Oasis 60 indirect evaporative cooling units on the roof, each for a design load of 360 kW and 55,000 CFM, on a pad of 310 by 140 inches, with a height limit of 180 inches and a support limit of 26,000 lb per unit. The quote states 750 kW and 120,000 CFM in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote two Munters Oasis 60 indirect evaporative cooling units on the roof, each for a design load of 360 kW and 55,000 CFM, on a pad of 310 by 140 inches, with a height limit of 190 inches and a support limit of 26,000 lb per unit. The quote states 750 kW and 120,000 CFM in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote three Munters Oasis 30 indirect evaporative cooling units on the roof, each for a design load of 210 kW and 28,000 CFM, on a pad of 320 by 100 inches. The quote states 600 kW and 90,000 CFM in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote three Munters Oasis 40 indirect evaporative cooling units on the roof, each for a design load of 210 kW and 28,000 CFM, on a pad of 320 by 100 inches. The quote states 750 kW and 120,000 CFM in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote two Munters Oasis 75 indirect evaporative cooling units on the roof, each for a design load of 500 kW and 70,000 CFM, on a pad of 350 by 170 inches, for extreme design conditions. The quote states 1,000 kW and 150,000 CFM in total. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote two Munters Oasis 75 indirect evaporative cooling units on the roof, each for a design load of 480 kW and 70,000 CFM, on a pad of 350 by 170 inches, for extreme design conditions, with trim DX supplemental cooling. The quote states 1,000 kW and 150,000 CFM in total. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.