Predictika · Patient monitoring quotes
An AI sales agent prepares a Nihon Kohden patient monitoring quote for an intensive care, neonatal, surgical or ward unit: Life Scope G9, TR and G7 core bedside monitors, Life Scope PT BSM-1733, 1753, 1763 and 1773 input and transport units, data acquisition units, CO2, IBP, cardiac output, BIS and NMT modules, the CNS-6201 central monitor, wireless licenses, batteries, installation and service. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of input-unit connectors, SpO2 sensor brands, core and central capacity, wireless, battery runtime, lead time and discount, and returns a verdict, every reason, a line-item quote and the figures it computed.
This validator models Nihon Kohden bedside monitoring quotes built from product names and facts in public FDA 510(k) summaries and trade pages, not just the scenarios shown below.
Any Nihon Kohden Life Scope quote that touches these products, limits and services is in scope — not only the scenarios pictured here. Not covered: other Nihon Kohden lines (defibrillators, ventilators, EEG), taxes, freight and regional price lists. The product names and the BSM-1700 facts above are public; the other limits and every price on this page are typical or invented for illustration.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| SpO2 sensor brand against the input unit | Only with care The BSM-1733, 1753 and 1763 each carry a different SpO2 technology, so the sensors on the order must match. A CPQ can pair them, but the sensor consumables are often a separate line or contract. | Input unit and sensor brand are inputs, and every pairing is compared on each call. |
| Modules against the multi-connector sockets | Only with workarounds Each input unit has three sockets, and the modules sit on separate lines. A rule has to add four kinds of module and compare them with three times the input units. | Module counts and input units are inputs, and the fit is computed and compared. |
| Which products suit which care unit | Only with care BIS, cardiac output and neonatal sensors belong to some units and not others. A rule per product is possible, but the care unit has to be a field on the quote and someone has to keep the list current. | The care unit is an input, and each product is compared with it. |
| Train-of-four and data acquisition units need a core monitor | Only with workarounds A transport-only order can still carry an NMT module or a data acquisition unit, because nothing on the quote says what they plug into. | Core monitors, input units, NMT modules and acquisition units are checked against each other. |
| Central monitor and wireless licenses against the beds | Only with workarounds The central monitor is licensed per bed and wireless per device. Both are separate lines from the monitors they cover, so a short license is found at installation. | Beds, monitors and licenses are inputs, and each is compared with the others. |
| Transport time against battery runtime | Only with workarounds A charge lasts about five hours. The hours of transport the hospital plans are not a product attribute, so spare batteries are decided by hand. | Planned transport hours and spare batteries are compared on every call. |
| A stated total that has to agree with the quote | Only with workarounds With dozens of monitors, modules and licenses, a missing central monitor or module in the typed total can pass unnoticed. | The total is computed from the choices and compared with the total the quote states. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote has 5 years of service, a long price commitment, so a person should confirm. |
| 2 | The quote has 2 years of service; service is quoted for 1, 3 or 5 years. |
| 3 | The quote has 24 core bedside monitors and does not say whether they are Life Scope G9, TR or G7. |
| 4 | The unit has 24 monitored beds and the quote has 23 core bedside monitors; every bed needs one. |
| 5 | The quote has 13 input units for 6 core monitors; a core monitor takes at most two input units. |
| 6 | The quote has 16 Life Scope PT input or transport units and does not say which BSM-1,700 model. |
| 7 | The SpO2 sensors on the quote are of a different make from the SpO2 technology built into the chosen input unit; the BSM-1,733 is Masimo, the BSM-1,753 is Nellcor, and the BSM-1,763 and BSM-1,773 are Nihon Kohden. |
| 8 | The quote has 49 parameter modules to plug in, and 16 input units provide 48 multi-connector sockets. |
| 9 | The quote has neuromuscular transmission modules and no core monitor; train-of-four monitoring works only with a core monitor, not on a standalone transport unit. |
| 10 | The quote is for an intensive care unit of 24 beds with no CNS-6,201 central monitor; units of 8 beds or more are quoted with one. |
| 11 | The quote has 13 data acquisition units and 12 input units; each unit connects one input unit to its core monitor. |
| 12 | The quote has data acquisition units and no core monitor for them to connect to. |
| 13 | The quote has BIS modules for a ward or neonatal unit; BIS monitoring is quoted for operating rooms and intensive care units. |
| 14 | The quote has cardiac output modules for a general ward; cardiac output monitoring is quoted for intensive care and operating rooms. |
| 15 | The quote is for a neonatal unit and includes no neonatal sensor sets. |
| 16 | The central monitor is licensed for 23 beds and the unit has 24. |
| 17 | The quote licenses 129 beds on one CNS-6,201 central monitor; one is quoted for at most 128. |
| 18 | The total is $2,360,570, above $1.5 million, so a person should confirm. |
| 19 | The quote has 41 wireless LAN licenses for 24 core monitors and 16 input or transport units. |
| 20 | The quote puts 40 monitors on the hospital wireless network with a central monitor, so hospital IT should review the network and security. |
| 21 | Transport runs for 6 hours, and one battery lasts about 5 hours; the quote has 3 spare batteries for 4 transport units. |
| 22 | The customer needs the monitors in 9 weeks, and the lead time for this order is 10 weeks. |
| 23 | The quote takes a discount of $48,547 against $485,460 of list price, above the 10 percent that needs a sales director. |
| 24 | The quote takes a discount of $87,383 against $485,460 of list price, above the 18 percent an agent may offer. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote Nihon Kohden patient monitoring for an intensive care unit of 60 beds. It includes 60 Life Scope G9 (CSM-1901) core bedside monitors, 38 Life Scope PT BSM-1733 units with Nellcor SpO2 sensors, 8 of them for transport, 14 JA-694PA data acquisition units, 26 CO2 modules, 40 invasive pressure modules, 15 cardiac output modules, 6 BIS modules and 6 AF-201P NMT modules, 40 wireless LAN licenses and 2 spare battery packs. Transport runs up to 7 hours. Service is for 3 years. The customer needs it in 8 weeks. The discount is $60,000. The quote states $1,167,300. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote Nihon Kohden patient monitoring for an intensive care unit of 60 beds. It includes 60 Life Scope G9 (CSM-1901) core bedside monitors, 38 Life Scope PT BSM-1733 units with Masimo SpO2 sensors, 8 of them for transport, 14 JA-694PA data acquisition units, 26 CO2 modules, 40 invasive pressure modules, 15 cardiac output modules, 6 BIS modules and 6 AF-201P NMT modules, a CNS-6201 central monitor licensed for 60 beds, 40 wireless LAN licenses and 8 spare battery packs. Transport runs up to 7 hours. Service is for 3 years. The customer needs it in 12 weeks. The discount is $60,000. The quote states $1,168,740. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote Nihon Kohden patient monitoring for an intensive care unit of 60 beds. It includes 60 Life Scope G9 (CSM-1901) core bedside monitors, 38 Life Scope PT BSM-1733 units with Masimo SpO2 sensors, 8 of them for transport, 14 JA-694PA data acquisition units, 26 CO2 modules, 40 invasive pressure modules, 15 cardiac output modules, 6 BIS modules and 6 AF-201P NMT modules, a CNS-6201 central monitor licensed for 60 beds and 8 spare battery packs. Transport runs up to 7 hours. Service is for 3 years. The customer needs it in 12 weeks. The discount is $60,000. The quote states $1,150,740. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote Nihon Kohden patient monitoring for a neonatal intensive care unit of 24 beds. It includes 24 Life Scope TR (BSM-6000 series) core bedside monitors, 16 Life Scope PT BSM-1763 units with Nihon Kohden SpO2 sensors, 4 of them for transport, 6 JA-694PA data acquisition units, 10 CO2 modules, 10 invasive pressure modules and 4 BIS modules, a CNS-6201 central monitor licensed for 20 beds and 4 spare battery packs. Transport runs up to 4 hours. Service is for 3 years. The customer needs it in 16 weeks. The discount is $30,000. The quote states $334,840. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote Nihon Kohden patient monitoring for a neonatal intensive care unit of 24 beds. It includes 24 Life Scope TR (BSM-6000 series) core bedside monitors, 16 Life Scope PT BSM-1763 units with Nihon Kohden SpO2 sensors, 4 of them for transport, 6 JA-694PA data acquisition units, 10 CO2 modules and 10 invasive pressure modules, a CNS-6201 central monitor licensed for 24 beds, 4 spare battery packs and neonatal sensor sets for every bed. Transport runs up to 4 hours. Service is for 3 years. The customer needs it in 16 weeks. The discount is $30,000. The quote states $334,840. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote Nihon Kohden patient monitoring for a surgical suite of 28 beds. It includes 28 Life Scope G7 (CSM-1701) core bedside monitors, 20 Life Scope PT BSM-1773 units with Nihon Kohden SpO2 sensors, 6 of them for transport, 8 JA-694PA data acquisition units, 20 CO2 modules, 20 invasive pressure modules, 6 cardiac output modules, 28 BIS modules and 28 AF-201P NMT modules and 6 spare battery packs. Transport runs up to 3 hours. Service is for 3 years. The customer needs it in 10 weeks. The discount is $40,000. The quote states $566,120. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote Nihon Kohden patient monitoring for a surgical suite of 28 beds. It includes 28 Life Scope G7 (CSM-1701) core bedside monitors, 26 Life Scope PT BSM-1773 units with Nihon Kohden SpO2 sensors, 6 of them for transport, 8 JA-694PA data acquisition units, 20 CO2 modules, 20 invasive pressure modules, 6 cardiac output modules, 28 BIS modules and 28 AF-201P NMT modules and 6 spare battery packs. Transport runs up to 3 hours. Service is for 3 years. The customer needs it in 10 weeks. The discount is $40,000. The quote states $617,060. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.