Predictika · Compressed air filter/regulators
An AI sales agent prepares an order for an Excelon B73G filter/regulator for a compressed air line: port size and thread, adjustment, drain, bowl, element, outlet pressure range, service conditions and the accessories that go with it. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the public Norgren datasheets and returns a verdict, every reason and the temperature limit it computed.
This validator models the Excelon B73G filter/regulator as described in the public IMI Norgren datasheets en 8.180.300 (B73G, 3/19) and en 8.210.300 (B72G, B73G and B74G, 01/26), not just the scenarios shown below.
Any B73G order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Norgren publishes none for this line), flow capacity (the two datasheets state different flow figures), the B72G and B74G sizes, other Excelon products, and combinations built from several Excelon units.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A 17 bar outlet range that is available only with the T-bar and the metal bowl | Only with care Each dependency is a separate product rule; they can be written, but each one is easy to miss when the options are edited. | All the choices travel in one request, so every dependency is checked together. |
| A permitted temperature limit that depends on the bowl and on whether the gauge is fitted | Only with workarounds The limit is a calculation over two choices, which a rules-based CPQ usually handles with custom code before it can compare it with the service temperature. | The limit is computed from the choices and compared with the service temperature on every call. |
| Accessories that must match the regulator (pipe adaptor by size and thread, gauge by thread, service kit by drain and element) | Only with care Each accessory needs its own lookup over the regulator options; a wrong part number looks fine in the quote. | The accessory is checked against the regulator in the same call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The B73G is for compressed air (the 01/26 sheet adds neutral gases); other media are for Norgren technical support, not an order. |
| 2 | The international sheet says compressed air only and the 01/26 sheet says compressed air and neutral gases; a person should confirm the gas with Norgren. |
| 3 | The lowest temperature 40 C is not below the highest temperature 20 C. |
| 4 | The lowest ambient or media temperature -40 C is below the -34 C limit of the B73G. |
| 5 | Below +2 C the air supply must be dry enough to avoid ice formation; a person should confirm the air quality for a lowest temperature of -40 C. |
| 6 | The highest ambient or media temperature 55 C is above the 50 C limit for this bowl and gauge choice (transparent bowl 50 C, metal bowl 80 C, version with gauge 65 C). |
| 7 | The highest ambient or media temperature 75 C is above the 65 C limit for this bowl and gauge choice (transparent bowl 50 C, metal bowl 80 C, version with gauge 65 C). |
| 8 | The sheets give temperature and pressure limits for the transparent and metal bowls but not separately for the guarded bowl; a person should confirm this service with Norgren. |
| 9 | The highest ambient or media temperature 90 C is above the 80 C limit for this bowl and gauge choice (transparent bowl 50 C, metal bowl 80 C, version with gauge 65 C). |
| 10 | Below +2 C the air supply must be dry enough to avoid ice formation; a person should confirm the air quality for a lowest temperature of 0 C. |
| 11 | The inlet pressure 12 bar is above the 10 bar maximum for this bowl (transparent bowl 10 bar, metal bowl 17 bar). |
| 12 | The inlet pressure 18 bar is above the 17 bar maximum for this bowl (transparent bowl 10 bar, metal bowl 17 bar). |
| 13 | The 0.7 to 17 bar outlet range is available only with T-bar adjustment. |
| 14 | The 0.7 to 17 bar outlet range is available only with the metal bowl. |
| 15 | A set pressure of 12 bar is outside the selected outlet pressure range of 0.3 to 10 bar; the sheet says not to use the unit outside its range. |
| 16 | A set pressure of 0.2 bar is outside the selected outlet pressure range of 0.3 to 10 bar; the sheet says not to use the unit outside its range. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote an Excelon B73G filter/regulator, 3/8 inch, PTF thread, knob adjustment, manual drain, transparent bowl, 40 micron element, no fitted gauge, outlet range 0.3 to 10 bar, relieving diaphragm. The inlet pressure is 8 bar, the set pressure 6 bar, the minimum air flow 5 dm3/s, and the ambient temperature runs from 10 to 35 C on compressed air. With it: a Quikclamp at the port, Quikmount pipe adaptor 4315-10 (G3/8), R1/8 gauge 0 to 10 bar (18-015-013), service kit B73G-KITA40R (auto drain, 40 micron). It is ready to send.
Verdict: Blocked.
The agent's request. Please quote an Excelon B73G filter/regulator, 3/8 inch, PTF thread, knob adjustment, manual drain, transparent bowl, 40 micron element, no fitted gauge, outlet range 0.3 to 10 bar, relieving diaphragm. The inlet pressure is 8 bar, the set pressure 6 bar, the minimum air flow 5 dm3/s, and the ambient temperature runs from 10 to 35 C on compressed air. With it: a Quikclamp at the port, Quikmount pipe adaptor 4315-02 (3/8 PTF), 1/4 NPT gauge 0 to 160 psig (18-015-209), service kit B73G-KITA40R (auto drain, 40 micron). It is ready to send.
Verdict: Blocked.
The agent's request. Please quote an Excelon B73G filter/regulator, 3/8 inch, PTF thread, knob adjustment, manual drain, transparent bowl, 40 micron element, no fitted gauge, outlet range 0.3 to 10 bar, relieving diaphragm. The inlet pressure is 8 bar, the set pressure 6 bar, the minimum air flow 5 dm3/s, and the ambient temperature runs from 10 to 35 C on compressed air. With it: a Quikclamp at the port, Quikmount pipe adaptor 4315-02 (3/8 PTF), 1/4 NPT gauge 0 to 160 psig (18-015-209), service kit B73G-KITM40R (manual drain, 40 micron). It is ready to send.
Verdict: Allowed.
The agent's request. Please quote an Excelon B73G filter/regulator, 1/2 inch, ISO G thread, knob adjustment, automatic drain, transparent bowl, 40 micron element, no fitted gauge, outlet range 0.7 to 17 bar, relieving diaphragm. The inlet pressure is 15 bar, the set pressure 12 bar, the minimum air flow 8 dm3/s, and the ambient temperature runs from 5 to 40 C on compressed air. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote an Excelon B73G filter/regulator, 1/2 inch, ISO G thread, T-bar adjustment, automatic drain, metal bowl with liquid level indicator, 40 micron element, no fitted gauge, outlet range 0.7 to 17 bar, relieving diaphragm. The inlet pressure is 15 bar, the set pressure 12 bar, the minimum air flow 8 dm3/s, and the ambient temperature runs from 5 to 40 C on compressed air. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote an Excelon B73G filter/regulator, 3/8 inch, ISO G thread, knob adjustment, automatic drain, metal bowl with liquid level indicator, 40 micron element, a fitted gauge, outlet range 0.3 to 10 bar, relieving diaphragm. The inlet pressure is 9 bar, the set pressure 6 bar, the minimum air flow 6 dm3/s, and the ambient temperature runs from 10 to 75 C on compressed air. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote an Excelon B73G filter/regulator, 3/8 inch, ISO G thread, knob adjustment, automatic drain, metal bowl with liquid level indicator, 40 micron element, no fitted gauge, outlet range 0.3 to 10 bar, relieving diaphragm. The inlet pressure is 9 bar, the set pressure 6 bar, the minimum air flow 6 dm3/s, and the ambient temperature runs from 10 to 75 C on compressed air. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.