Predictika · Sequencing device, flow cell and kit orders
An AI sales agent prepares an order for a nanopore sequencing device with its flow cells, library prep kit and auxiliary reagents. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the compatibility and ordering rules and returns a verdict, every reason and the figures it computed.
This validator models orders for four Oxford Nanopore sequencing devices (MinION Mk1D, GridION, PromethION 2 Integrated, PromethION 24), not just the scenarios shown below.
Any order for these four devices that touches these rules is in scope — not only the scenarios pictured here. Not covered: how many flow cells a run needs (the store pages do not say, and flow cells can be washed and reused, so flow cell quantities are not checked), prices (devices are price on request and store prices vary by region, so this validator produces no price build-up or line-item quote), Flongle and other devices, XL and early-access kits, PCR barcoding and other expansions, support plans and regional terms.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Flow cells that fit only one device family | Only with care A product rule per device and flow cell. It works, but every new device or flow cell is another set of rules to maintain. | The device and flow cell are in one request and the pairing is checked with everything else. |
| DNA kits on DNA flow cells, RNA kits on RNA flow cells, and reagents for one chemistry | Only with workarounds Each depends on a choice on one line and another choice on a different line, so they need cross-line rules that interact with the rest. | Every choice is in one request, so the conflict is found whichever order the choices arrive in. |
| Libraries per kit that change with the number of samples | Only with workarounds A 96-barcode kit prepares 12, 6 or 3 libraries depending on samples per library; that needs a calculated field fed by another line, then a comparison with the plan. | The library count per kit is computed on every call from the samples per library and compared with the plan. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The flow cell on the order is not a flow cell for the selected device; MinION Mk1D and GridION take MinION flow cells, PromethION 2 Integrated and PromethION 24 take PromethION flow cells. |
| 2 | The library prep kit and the flow cell are for different molecules; RNA kits go with RNA flow cells (FLO-MIN004RA, FLO-PRO004RA) and DNA kits go with DNA flow cells (FLO-MIN114, FLO-PRO114M). |
| 3 | The auxiliary reagent on the order does not fit the kit; Sequencing Auxiliary Vials V14 (EXP-AUX003) are for Kit 14 DNA chemistry only and Direct RNA Auxiliary Vials (EXP-DRA004) are for the direct RNA kits only. |
| 4 | The run plan has 5 flow cells running at the same time, but the selected device can run no more than 1 at the same time. |
| 5 | The run plan has 3 flow cells running at the same time, but the selected device can run no more than 2 at the same time. |
| 6 | The run plan has 6 flow cells running at the same time, but the selected device can run no more than 5 at the same time. |
| 7 | 30 samples are planned per library, but the selected kit allows a maximum of 24 per library. |
| 8 | 2 samples are planned per library, but the selected kit allows a maximum of 1 per library. |
| 9 | 100 samples are planned per library, but the selected kit allows a maximum of 96 per library. |
| 10 | 12 libraries are planned, but the kits on the order prepare only 6. |
| 11 | 24 libraries are planned, but the kits on the order prepare only 18. |
| 12 | The order states that it covers 20 libraries, but the library prep kits on it prepare 12. |
| 13 | The order states that it covers 10 libraries, but the library prep kits on it prepare 12. |
| 14 | These Oxford Nanopore products are for research use only (RUO) and are not for use in diagnostic procedures. |
| 15 | The run plan has 30 flow cells running at the same time, but the selected device can run no more than 24 at the same time. |
| 16 | 24 libraries are planned, but the kits on the order prepare only 6. |
| 17 | The order states that it covers 24 libraries, but the library prep kits on it prepare 6. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a GridION order for 12 libraries of 24 samples each, with the PromethION flow cell pack of 4, DNA (FLO-PRO114M) and 1 x Native Barcoding Kit 24 V14 (SQK-NBD114.24), run with 5 flow cells at the same time, for research use. The order states that it covers 12 libraries. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a GridION order for 12 libraries of 24 samples each, with the MinION/GridION flow cell, DNA (FLO-MIN114) and 2 x Native Barcoding Kit 24 V14 (SQK-NBD114.24), run with 5 flow cells at the same time, for research use. The order states that it covers 12 libraries. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a PromethION 24 order for 24 libraries of 96 samples each, with the PromethION flow cell pack of 4, DNA (FLO-PRO114M) and 2 x Native Barcoding Kit 96 V14 (SQK-NBD114.96) and the Sequencing Auxiliary Vials V14 (EXP-AUX003), run with 24 flow cells at the same time, for research use. The order states that it covers 24 libraries. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a PromethION 24 order for 24 libraries of 96 samples each, with the PromethION flow cell pack of 4, DNA (FLO-PRO114M) and 3 x Native Barcoding Kit 96 V14 (SQK-NBD114.96) and the Sequencing Auxiliary Vials V14 (EXP-AUX003), run with 24 flow cells at the same time, for research use. The order states that it covers 9 libraries. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a PromethION 24 order for 24 libraries of 96 samples each, with the PromethION flow cell pack of 4, DNA (FLO-PRO114M) and 8 x Native Barcoding Kit 96 V14 (SQK-NBD114.96) and the Sequencing Auxiliary Vials V14 (EXP-AUX003), run with 24 flow cells at the same time, for research use. The order states that it covers 24 libraries. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a PromethION 2 Integrated order for 12 libraries of 1 sample each, with the PromethION flow cell pack of 4, DNA (FLO-PRO114M) and 2 x Direct RNA Sequencing Kit (SQK-RNA004) and the Sequencing Auxiliary Vials V14 (EXP-AUX003), run with 2 flow cells at the same time, for diagnostic use. The order states that it covers 12 libraries. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a PromethION 2 Integrated order for 12 libraries of 1 sample each, with the PromethION flow cell pack of 4, RNA (FLO-PRO004RA) and 2 x Direct RNA Sequencing Kit (SQK-RNA004) and the Direct RNA Auxiliary Vials (EXP-DRA004), run with 2 flow cells at the same time, for research use. The order states that it covers 12 libraries. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.