Predictika · Dairy farm equipment
An AI sales agent prepares a quote for a farm's bulk milk cooler: the tank size, the refrigeration unit on each cooling circuit (OE or HiPerForm EVC, size and electrical supply), the refrigerant, the milk in the tank when cooling starts, the clearance under the cooler, and the refrigeration capacity and weight it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the tables in Paul Mueller's public Milk Cooler Dimensions and Capacities manual and returns a verdict, every reason and the figures it computed.
This validator models a bulk milk cooler with its refrigeration units, based on the tables in Paul Mueller's Milk Cooler Dimensions and Capacities manual (MC-275-9, revised July 7, 2015), not just the scenarios shown below.
Any milk cooler quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none are published, so this page shows no price build-up), the other cooler sizes and 2,000C-D and 4,000L models whose tables the manual does not complete, coolers built before 2009, R-22 and discontinued units, unit mixes with different types on different circuits, chillers, milk-load (Btu per milking) calculations, and installation, electrical and plumbing design.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| The largest refrigeration unit allowed on each evaporator, by cooler and unit type | Only with workarounds Each of 18 tank sizes has one to four circuits, each with its own limit, and the limit changes with the unit type (a 5 horsepower unit passes on some circuits only as a HiPerForm). A rules-based CPQ needs a lookup table or a rule per tank, circuit and type, and the manual's next revision means editing them. | All circuits are compared with the published limits, whichever unit type is chosen, on every call. |
| Refrigeration capacity that adds up unit ratings by type, size and power | Only with care Each unit's Btu per hour depends on its type, its size and the electrical supply, and the total must be compared with the capacity the quote states. | The ratings are looked up, summed over the circuits that exist and compared with the stated figure on every call. |
| Circuits that exist for this cooler, and units that match them | Only with care A single, dual, triple or quad cooler has a different set of circuits; a missing unit or a unit on a circuit that is not there is easy to miss. | The circuits of the chosen tank are derived, and a missing or extra unit is reported. |
| Weight and supply constraints stated in the quote | Only with care Stated figures are derived from the tank row, so a rule has to recompute them and compare. | The stated capacity and weight are fields in the request, compared with the computed ones. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The side unit (left side unit on a triple or quad) is 5 horsepower; the recommended maximum for that evaporator with this unit type is 3.5 horsepower. |
| 2 | The side unit (left side unit on a triple or quad) is 7.5 horsepower; the recommended maximum for that evaporator with this unit type is 5 horsepower. |
| 3 | The bottom unit (left bottom unit on a quad) is 7.5 horsepower; the recommended maximum for that evaporator with this unit type is 5 horsepower. |
| 4 | The bottom unit (left bottom unit on a quad) is 5 horsepower; the recommended maximum for that evaporator with this unit type is 3.5 horsepower. |
| 5 | The bottom unit (left bottom unit on a quad) is 9 horsepower; the recommended maximum for that evaporator with this unit type is 7.5 horsepower. |
| 6 | The right bottom unit is 9 horsepower; the recommended maximum for that evaporator with this unit type is 7.5 horsepower. |
| 7 | The side unit (left side unit on a triple or quad) is 9 horsepower; the recommended maximum for that evaporator with this unit type is 7.5 horsepower. |
| 8 | The right side unit is 9 horsepower; the recommended maximum for that evaporator with this unit type is 7.5 horsepower. |
| 9 | This cooler has 4 refrigeration circuits and every circuit needs its own refrigeration unit; at least one circuit has none. |
| 10 | A refrigeration unit is selected for a circuit this cooler does not have; it has 1 circuit. |
| 11 | This cooler has 3 refrigeration circuits and every circuit needs its own refrigeration unit; at least one circuit has none. |
| 12 | The current refrigeration unit charts list 3.5, 5, 7.5 and 9 horsepower units; a unit of another size is selected. |
| 13 | The bottom unit (left bottom unit on a quad) is 10 horsepower; the recommended maximum for that evaporator with this unit type is 7.5 horsepower. |
| 14 | Single-phase units are listed only for 3.5 and 5 horsepower; a unit of 7.5 horsepower is three-phase only. |
| 15 | R-22 refrigeration units have not been available since January 1, 2010; current units use R-507. |
| 16 | The plan puts 2,001 gallons in a 2,000 gallon tank. |
| 17 | The requested clearance under the cooler of 10 inches is outside the standard leg range of 7 to 9 inches for this size. |
| 18 | The requested clearance under the cooler of 6 inches is outside the standard leg range of 7 to 9 inches for this size. |
| 19 | The requested clearance under the cooler of 6 inches is outside the standard leg range of 4 to 5 inches for this size. |
| 20 | The requested clearance under the cooler of 9 inches is outside the standard leg range of 4 to 8 inches for this size. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a Paul Mueller 2,000-gallon dual-circuit milk cooler with OE (mechanical expansion valve) refrigeration units: a 5 HP on the bottom circuit, a 5 HP on the side circuit. The supply is 208-230 volt three-phase and the refrigerant is R-507. The tank holds 1,800 gallons of milk when cooling starts, the legs should give 8 inches of clearance under the cooler, and the quote states 112,000 Btu per hour of refrigeration and a cooler weight of 2,432 pounds. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Paul Mueller 2,000-gallon dual-circuit milk cooler with OH HiPerForm (electronic valve control) refrigeration units: a 5 HP on the bottom circuit, a 5 HP on the side circuit. The supply is 208-230 volt three-phase and the refrigerant is R-507. The tank holds 1,800 gallons of milk when cooling starts, the legs should give 8 inches of clearance under the cooler, and the quote states 117,992 Btu per hour of refrigeration and a cooler weight of 2,432 pounds. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Paul Mueller 6,700-gallon quad-circuit milk cooler with OE (mechanical expansion valve) refrigeration units: a 9 HP on the left bottom circuit, a 9 HP on the right bottom circuit, a 7.5 HP on the left side circuit, a 7.5 HP on the right side circuit. The supply is 460 volt three-phase and the refrigerant is R-507. The tank holds 5,000 gallons of milk when cooling starts, the legs should give 8 inches of clearance under the cooler, and the quote states 370,600 Btu per hour of refrigeration and a cooler weight of 7,324 pounds. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Paul Mueller 6,700-gallon quad-circuit milk cooler with OH HiPerForm (electronic valve control) refrigeration units: a 9 HP on the left bottom circuit, a 9 HP on the right bottom circuit, a 7.5 HP on the left side circuit, a 7.5 HP on the right side circuit. The supply is 460 volt three-phase and the refrigerant is R-507. The tank holds 5,000 gallons of milk when cooling starts, the legs should give 8 inches of clearance under the cooler, and the quote states 390,426 Btu per hour of refrigeration and a cooler weight of 7,324 pounds. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Paul Mueller 2,000-gallon dual-circuit milk cooler with OH HiPerForm (electronic valve control) refrigeration units: a 5 HP on the bottom circuit, a 3.5 HP on the side circuit. The supply is 208-230 volt three-phase and the refrigerant is R-507. The tank holds 120 gallons of milk when cooling starts, the legs should give 10 inches of clearance under the cooler, and the quote states 100,188 Btu per hour of refrigeration and a cooler weight of 2,432 pounds. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Paul Mueller 2,000-gallon dual-circuit milk cooler with OH HiPerForm (electronic valve control) refrigeration units: a 5 HP on the bottom circuit, a 3.5 HP on the side circuit. The supply is 208-230 volt three-phase and the refrigerant is R-507. The tank holds 120 gallons of milk when cooling starts, the legs should give 9 inches of clearance under the cooler, and the quote states 100,188 Btu per hour of refrigeration and a cooler weight of 2,432 pounds. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a Paul Mueller 2,000-gallon dual-circuit milk cooler with OH HiPerForm (electronic valve control) refrigeration units: a 5 HP on the bottom circuit, a 3.5 HP on the side circuit. The supply is 208-230 volt three-phase and the refrigerant is R-507. The tank holds 150 gallons of milk when cooling starts, the legs should give 9 inches of clearance under the cooler, and the quote states 100,188 Btu per hour of refrigeration and a cooler weight of 2,432 pounds. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.