Predictika · Water treatment
An AI sales agent prepares a quote for a ProMinent gamma/ X solenoid-driven metering pump: the pump type, dosing head material, seals and diaphragm, liquid end version, relay, control variant and accessories, and the duty the customer describes (flow, back pressure and suction lift) together with the capacity it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the figures ProMinent publishes and returns a verdict, every reason and the figures it computed.
This validator models one gamma/ X pump configuration at a time (with any number of identical pumps), based on the gamma/ X section of the public ProMinent Product Catalogue Volume 1 (edition 01.01.2026, read October 9, 2026), not just the scenarios shown below.
Any gamma/ X pump built from these options is in scope — not only the scenarios pictured here. Not covered: prices (the catalogue lists none, so this page shows no price build-up), other ProMinent pump ranges (beta, delta, Sigma, Concept, motor-driven and process pumps), spare parts, dosing systems, controllers and sensors, tube and hose sizing, and chemical compatibility.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Which seals fit which dosing head, and which liquid end version fits which head and pump type | Only with workarounds These are compatibility matrices in several directions at once, and a person has to keep them in step with the catalogue footnotes. | Head, seals, version and pump type are compared together, in any order. |
| Back pressure and suction lift against the pump, which change with the liquid end version | Only with care The rating depends on the version (the self-bleeding head has its own capacity and lift figures), so it takes a rule per pump type and version. | The rating for the chosen pump and version is looked up and compared on every call. |
| Options that exclude each other: a relay with a fieldbus control variant, an accessories kit with PVT4, a bleed valve on type 0245 | Only with workarounds Each exclusion is a rule of its own, and a rep can pick them in any order, so the error surfaces late. | They are checked with the other rules, whatever order the choices arrive in. |
| Flow the customer needs against the capacity of one or several pumps | Only with care It needs a quantity roll-up and a capacity figure per type and version, and a higher-viscosity head lowers the capacity again. | Pumps times the catalogue capacity is compared with the flow on every call. |
| A quote that states a capacity the catalogue does not give | Not caught A stated figure is free text to a CPQ, so nothing compares it with the product data. | The stated figure is compared with the computed one. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The process back pressure is 8 bar; the chosen pump and liquid end version is rated 7 bar at most. |
| 2 | The customer needs 7,601 ml/h; the catalogue gives 7,600 ml/h for the pumps at maximum back pressure, so a person should confirm the flow at the process pressure. |
| 3 | The customer needs 15,201 ml/h; the catalogue gives 15,200 ml/h for the pumps at maximum back pressure, so a person should confirm the flow at the process pressure. |
| 4 | The suction lift is 401 cm of water column; the chosen pump and liquid end version gives 400 cm. |
| 5 | The process back pressure is 17 bar; the chosen pump and liquid end version is rated 16 bar at most. |
| 6 | The 25 bar type 2504 is available only with a clear acrylic or stainless steel dosing head. |
| 7 | The FKM and EPDM seal versions (with their own ball seats) are offered only with polypropylene and clear acrylic dosing heads. |
| 8 | The FDA-compliant design is offered only with PVDF and stainless steel dosing heads. |
| 9 | The EC 1935/2004-compliant design is offered only with the stainless steel dosing head. |
| 10 | Pumps with the vPTFE diaphragm may deliver 10 to 20 percent less than the catalogue capacity; a person should confirm the capacity. |
| 11 | The vPTFE diaphragm with PTFE valve seats is offered only with the PVDF dosing head. |
| 12 | Liquid end versions 0 and 1 (non-bleed) are offered only with clear acrylic, PTFE and stainless steel dosing heads, and with type 0245. |
| 13 | Liquid end versions 2 and 3 (with bleed valve) are offered only with polypropylene, PVDF and clear acrylic dosing heads, and not with type 0245. |
| 14 | Liquid end version 4 for higher-viscosity media may deliver 10 to 20 percent less than the catalogue capacity and is not self-priming with all feed chemicals; a person should confirm the capacity and the medium. |
| 15 | Liquid end version 4 for higher-viscosity media is offered only with the PVDF dosing head. |
| 16 | Liquid end version 4 for higher-viscosity media is offered only with types 1604, 0708, 0414, 1009, 0715 and 0424. |
| 17 | The suction lift is 181 cm of water column; the chosen pump and liquid end version gives 180 cm. |
| 18 | Liquid end version 7 (self-bleeding without bypass) is offered only for the NPT and PVT combinations, clear acrylic or PVDF head with PTFE seals. |
| 19 | Liquid end version 7 is not offered for type 1602, and the catalogue lists no self-degassing data for type 2504. |
| 20 | The process back pressure is 12 bar; the chosen pump and liquid end version is rated 10 bar at most. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 1 ProMinent gamma/ X metering pump, type 0708, with a PVDF dosing head and FKM seals. The liquid end is version 2 (with bleed valve, without valve spring). The pump has no relay, control by manual and external pulse control, no accessories kit and no diaphragm rupture indicator. The customer needs 6,000 ml/h at 5 bar back pressure, with a suction lift of 200 cm of water column. The quote states a capacity of 8,000 ml/h per pump. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 ProMinent gamma/ X metering pump, type 0708, with a polypropylene dosing head and FKM seals. The liquid end is version 2 (with bleed valve, without valve spring). The pump has no relay, control by manual and external pulse control, no accessories kit and no diaphragm rupture indicator. The customer needs 6,000 ml/h at 5 bar back pressure, with a suction lift of 200 cm of water column. The quote states a capacity of 7,600 ml/h per pump. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 ProMinent gamma/ X metering pump, type 1009, with a polypropylene dosing head and EPDM seals. The liquid end is version 0 (non-bleed, without valve spring). The pump has no relay, control by manual and external pulse control, no accessories kit and a diaphragm rupture indicator. The customer needs 8,000 ml/h at 12 bar back pressure, with a suction lift of 300 cm of water column. The quote states a capacity of 9,500 ml/h per pump. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 ProMinent gamma/ X metering pump, type 1009, with a polypropylene dosing head and EPDM seals. The liquid end is version 2 (with bleed valve, without valve spring). The pump has no relay, control by manual and external pulse control, no accessories kit and a diaphragm rupture indicator. The customer needs 9,500 ml/h at 10 bar back pressure, with a suction lift of 300 cm of water column. The quote states a capacity of 9,000 ml/h per pump. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 2 ProMinent gamma/ X metering pumps, type 1009, with a polypropylene dosing head and EPDM seals. The liquid end is version 2 (with bleed valve, without valve spring). The pump has no relay, control by manual and external pulse control, no accessories kit and a diaphragm rupture indicator. The customer needs 9,500 ml/h at 10 bar back pressure, with a suction lift of 300 cm of water column. The quote states a capacity of 9,000 ml/h per pump. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 ProMinent gamma/ X metering pump, type 0414, with a clear acrylic dosing head and PTFE seals. The liquid end is version 7 (self-bleeding without bypass). The pump has the fault indicating relay (230 V), control by Modbus, the accessories kit (foot valve, metering valve and lines) and no diaphragm rupture indicator. The customer needs 11,000 ml/h at 3 bar back pressure, with a suction lift of 250 cm of water column. The quote states a capacity of 13,500 ml/h per pump. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 ProMinent gamma/ X metering pump, type 0414, with a clear acrylic dosing head and PTFE seals. The liquid end is version 1 (non-bleed, with valve spring). The pump has no relay, control by Modbus, the accessories kit (foot valve, metering valve and lines) and no diaphragm rupture indicator. The customer needs 11,000 ml/h at 3 bar back pressure, with a suction lift of 250 cm of water column. The quote states a capacity of 13,500 ml/h per pump. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.