Predictika · Distribution transformer orders
An AI sales agent prepares an order for Prolec GE distribution transformers: single-phase pole-mount, single-phase pad-mount or three-phase pad-mount, with rating, quantity, primary and secondary voltage, impulse level, options and site altitude, and the total kVA the order states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the brochure's published ranges and options and returns a verdict, every reason and the figures it computed.
This validator models the distribution transformer ranges in Prolec GE's public brochure, not just the scenarios shown below.
Any distribution transformer order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the brochure lists none, so this validator produces no price build-up or line-item quote), power, substation, wind and solar transformers, network transformers and voltage regulators, and custom designs.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A standard voltage table that sets the impulse level | Only with workarounds A lookup from primary voltage and connection to the standard impulse level has to be built as a table and a price-style rule, and re-checked whenever the brochure is reprinted. | The voltage, connection and impulse level arrive together and are checked on every call. |
| Different impulse-level ranges for dead-front, live-front and single-phase units | Only with care Three separate range rules, each conditional on type and front; easy to miss one when a type is added. | Each range is checked with every other rule in the same call. |
| A dual-voltage primary that cannot be combined with a tap changer on single-phase units | Only with care An exclusion rule between two options, restricted to certain types; it works, but each such exclusion is another rule to write and test. | The exclusion is checked against the unit type on every call, whatever order the choices were made in. |
| Options listed for one transformer type but not for another | Only with care A compatibility matrix of options against types; every new option or type extends the matrix. | Options are checked against the unit type together, and anything outside the brochure goes to a person for approval. |
| A stated total kVA that must equal quantity times rating | Only with workarounds A stated figure is a free-entry field; a rule can compare it with a computed total, but someone has to write and maintain that comparison. | The stated total travels with the order and is compared with the computed total on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote states a total of 500 kVA, but the transformers on it total 1,000 kVA. |
| 2 | The quote states a total of 550 kVA, but the transformers on it total 500 kVA. |
| 3 | A primary voltage of 46,000 V is above the 34,500 V that this range goes up to. |
| 4 | The secondary voltage on the quote does not match the number of phases of the transformer type; single-phase units have 120/240, 240/480 or 277 V secondaries and three-phase pad-mount units have 208Y/120 or 480Y/277 V. |
| 5 | A dual-voltage primary is not available with an external tap changer on single-phase units. |
| 6 | The self-protected (CSP) design is a pole-mount option; it is not offered on pad-mount transformers. |
| 7 | The primary impulse level of 45 kV is outside the 60 to 150 kV range offered on single-phase units. |
| 8 | The primary impulse level of 200 kV is outside the 60 to 150 kV range offered on single-phase units. |
| 9 | The primary impulse level of 200 kV is outside the 45 to 150 kV range offered with a dead-front primary. |
| 10 | The standard primary impulse level for this voltage is 150 kV; 200 kV is not in the standard table, so confirm it with a sales representative. |
| 11 | The primary impulse level of 250 kV is outside the 45 to 200 kV range offered with a live-front primary. |
| 12 | The standard primary impulse level for this voltage is 95 kV; 250 kV is not in the standard table, so confirm it with a sales representative. |
| 13 | The primary impulse level of 30 kV is outside the 45 to 150 kV range offered with a dead-front primary. |
| 14 | The standard primary impulse level for this voltage is 45 kV; 30 kV is not in the standard table, so confirm it with a sales representative. |
| 15 | An altitude of 3,500 m is above the 3,000 m up to which the three-phase pad-mount transformer is designed. |
| 16 | A rating of 5,000 kVA is not on the standard list for this transformer type; Prolec asks that such ratings go to a sales representative. |
| 17 | A rating of 6,000 kVA is above the 5,000 kVA (ONAN) that the three-phase pad-mount range goes up to. |
| 18 | A rating of 6,000 kVA is not on the standard list for this transformer type; Prolec asks that such ratings go to a sales representative. |
| 19 | A rating of 400 kVA is not on the standard list for this transformer type; Prolec asks that such ratings go to a sales representative. |
| 20 | A rating of 200 kVA is not on the standard list for this transformer type; Prolec asks that such ratings go to a sales representative. |
| 21 | A primary voltage of 14,000 V with this connection is not in the standard table for three-phase pad-mount units; confirm it with a sales representative. |
| 22 | The standard primary impulse level for this voltage is 95 kV; 110 kV is not in the standard table, so confirm it with a sales representative. |
| 23 | The 277 V secondary is listed for pole-mount units; the pad-mount single-phase units list 120/240 and 240/480 V. |
| 24 | A live-front primary is listed for three-phase pad-mount units; for this type confirm availability with a sales representative. |
| 25 | A low-voltage circuit breaker is not listed among the options of the single-phase pad-mount unit; confirm it with a sales representative. |
| 26 | A two-position or load-break switch is not listed among the options of the pole-mount unit; confirm it with a sales representative. |
| 27 | Seismic zone designs are listed for three-phase pad-mount units; for this type confirm availability with a sales representative. |
| 28 | The 55 C and 55/65 C temperature rises are listed for three-phase units; the single-phase brochure lists no temperature-rise option. |
| 29 | Copper windings are listed as an option for three-phase units; the single-phase brochure lists none, so confirm with a sales representative. |
| 30 | The quote states a total of 900 kVA, but the transformers on it total 800 kVA. |
| 31 | The primary impulse level of 250 kV is outside the 45 to 150 kV range offered with a dead-front primary. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 6 three-phase pad-mount distribution transformers of 1500 kVA each, primary 13,800 V with a 95 kV impulse level, secondary 240/480 V, VG-100 vegetable oil, copper windings, for a site at 2,400 m. Options: seismic zone design. The order states a total of 7,500 kVA. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 6 three-phase pad-mount distribution transformers of 1500 kVA each, primary 13,800 V with a 95 kV impulse level, secondary 480Y/277 V, VG-100 vegetable oil, copper windings, for a site at 2,400 m. Options: seismic zone design. The order states a total of 9,000 kVA. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 24 single-phase pole-mount distribution transformers of 100 kVA each, primary 7,200 V with a 75 kV impulse level, secondary 120/240 V, mineral oil, for a site at 500 m. Options: a dual-voltage primary, an external tap changer, a load-break switch. The order states a total of 2,400 kVA. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 24 single-phase pole-mount distribution transformers of 100 kVA each, primary 7,200 V with a 75 kV impulse level, secondary 120/240 V, mineral oil, for a site at 500 m. Options: a dual-voltage primary, a load-break switch. The order states a total of 2,400 kVA. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 24 single-phase pole-mount distribution transformers of 100 kVA each, primary 7,200 V with a 75 kV impulse level, secondary 120/240 V, mineral oil, for a site at 500 m. Options: a dual-voltage primary. The order states a total of 2,400 kVA. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 16 single-phase pad-mount distribution transformers of 75 kVA each, primary 12,470 V grounded wye with a 95 kV impulse level, secondary 240/480 V, mineral oil, for a site at 500 m. Options: the self-protected design, a low-voltage breaker. The order states a total of 1,200 kVA. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 16 single-phase pad-mount distribution transformers of 75 kVA each, primary 12,470 V grounded wye with a 95 kV impulse level, secondary 240/480 V, mineral oil, for a site at 500 m. The order states a total of 1,200 kVA. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.