Predictika · Nonwoven extrusion line quotes

An AI sales agent's nonwoven line quote, checked before it goes out

An AI sales agent prepares a quote for a nonwovens producer that wants a Reicofil spunbond, composite or meltblown line: the line family, the width, the beam configuration, the basis weight and speed, the output it needs and the options. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published line data and returns a verdict, every reason and the figures it computed.

Scope: Reicofil RF5 and RF Smart spunbond and composite lines and RF Meltblown lines: width, beam configuration, basis weight, conveyor speed, output, raw material and options. See everything this validator covers

This validator models nonwoven line quotes as published on the Reifenhaeuser Reicofil line pages (read October 5, 2026), not just the scenarios shown below.

  • Line families and widths — RF5 spunbond and composite lines in widths of 1000, 1600, 2400, 3200, 4200, 4400, 5200 and 5400 mm; RF Smart lines in 1600, 2400 and 3200 mm; RF Meltblown in 1000, 1600, 2400 and 3200 mm, with other widths on request.
  • Configurations — spunbond lines with one to three spunbond beams (S, SS, SSS); meltblown lines with one or two (M, MM); composite lines from SMS up to SSMMMMSS on RF5 and up to SS(MM)(MM)S on RF Smart. Configurations between the two published ends of a composite line go to a person.
  • Limits and figures — basis weight (7 to 70 g/m² for RF5 spunbond, 8 to 70 for the other spunbond and composite lines), conveyor speed (up to 1200 m/min for RF5, 800 for RF Smart), and the published maximum specific throughput (270 kg/h/m for RF5, 180 for RF Smart, 100 or 150 for meltblown singlerow and multirow) multiplied by the line width.
  • Options and materials — loft options, charging unit and raw materials are checked against the lists on each line page; an option or material that a page does not list goes to a person rather than being refused.

Any Reicofil nonwoven line quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none are published, so there is no price build-up or line-item quote), blown film and other Reifenhaeuser extrusion lines, titer ranges, annual capacity, winder speed, energy packages and digital options, and anything beyond the data on the line pages. The throughput figure is published per metre of width; how it applies across the beams of a multi-beam line is not stated, so a requested output above the computed maximum goes to a person.

The AI sales agentBuilds the nonwoven line quote from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
Widths that differ by line familyOnly with care
Each family has its own list of widths, so a rule per family works, but every list has to be kept in step with the published data.
The width is checked against the list for the chosen family on every call, whatever order the choices arrive in.
A beam configuration that depends on the lineOnly with workarounds
Spunbond, meltblown and composite lines allow different numbers of beams, and the composite limits differ between families; this usually becomes a long list of allowed combinations.
The numbers of spunbond and meltblown beams travel in one request and are checked together against the family, including configurations that need a person.
A maximum output that depends on width and familyOnly with workarounds
The maximum is a specific throughput times the width, which changes with the family and the meltblown type, and a figure typed by a rep has to be compared with it separately.
The maximum is computed from the family and width and compared with both the stated figure and the requested output.
Options that exist only on some linesOnly with care
Loft options, the charging unit and raw materials differ by line, so each is a product rule per line that has to be maintained.
Every option is checked against its line in the same pass as the rest, and an option the data does not list goes to a person.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1A line width of 3,000 mm is not one of the published widths for this line family.
2A line width of 4,200 mm is not one of the published widths for this line family.
34 spunbond beams and 0 meltblown beams is outside the published configurations for this line family.
42 spunbond beams and 1 meltblown beam is outside the published configurations for this line family.
51 spunbond beam and 1 meltblown beam is outside the published configurations for this line family.
60 spunbond beams and 3 meltblown beams is outside the published configurations for this line family.
72 spunbond beams and 0 meltblown beams is outside the published configurations for this line family.
83 spunbond beams and 1 meltblown beam lies between the two end configurations the data names for this composite line; a person should confirm it is offered.
95 spunbond beams and 4 meltblown beams is outside the published configurations for this line family.
104 spunbond beams and 4 meltblown beams is outside the published configurations for this line family.
11A basis weight of 6 g/m² is outside the published range of 7 to 70 g/m² for this line.
12A basis weight of 7 g/m² is outside the published range of 8 to 70 g/m² for this line.
13A basis weight of 71 g/m² is outside the published range of 8 to 70 g/m² for this line.
14A conveyor speed of 1,300 m/min is above the published maximum of 1,200 m/min for this line family.
15A conveyor speed of 900 m/min is above the published maximum of 800 m/min for this line family.
16The quote states a maximum output of 900 kg/h; the published specific throughput times the line width gives 864 kg/h.
17The requested output of 1,000 kg/h is above 864 kg/h, the published maximum specific throughput times the line width; a person should check it against the beam layout.
18A width of 2,000 mm is not in the published meltblown list of 1000, 1600, 2,400 and 3,200 mm; the page says other widths are on request, so a person should confirm it.
19The selected loft option is not listed in the published data for this line family; a person should confirm it is offered.
20The charging unit is listed in the published data only for the RF Meltblown line; a person should confirm it for this line.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Smart composite line: RF Smart Composite with an unlisted width, a speed above the maximum and a low basis weight

The agent's request. Please quote a Reicofil RF Smart Composite line 4,200 mm wide with 2 spunbond beams and 1 meltblown beam, a basis weight of 5 g/m² and a conveyor speed of 900 m/min, in PP. The customer needs 400 kg/h, and the quote states a maximum output of 756 kg/h for the line. It is ready to send.

Verdict: Blocked.

  • Width not offered for this line. A line width of 4,200 mm is not one of the published widths for this line family.
  • Basis weight outside the published range. A basis weight of 5 g/m² is outside the published range of 8 to 70 g/m² for this line.
  • Conveyor speed above the published maximum. A conveyor speed of 900 m/min is above the published maximum of 800 m/min for this line family.

2. Smart composite line: The agent resubmits after fixing the errors

The agent's request. Please quote a Reicofil RF Smart Composite line 3,200 mm wide with 2 spunbond beams and 1 meltblown beam, a basis weight of 20 g/m² and a conveyor speed of 800 m/min, in PP. The customer needs 400 kg/h, and the quote states a maximum output of 576 kg/h for the line. It is ready to send.

Verdict: Allowed.

  • Quote summary. 3,200 mm wide; published maximum specific throughput 180 kg/h/m gives 576 kg/h; requested output 400 kg/h; 2 spunbond beams and 1 meltblown beam.

3. RF5 spunbond line: RF5 Spunbond with four beams and a wrong output figure

The agent's request. Please quote a Reicofil RF5 Spunbond line 3,200 mm wide with 4 spunbond beams, a basis weight of 15 g/m² and a conveyor speed of 1,000 m/min, in PP, with High Loft. The customer needs 1,000 kg/h, and the quote states a maximum output of 1,200 kg/h for the line. It is ready to send.

Verdict: Blocked.

  • Beam configuration not offered. 4 spunbond beams and 0 meltblown beams is outside the published configurations for this line family.
  • Stated maximum output differs from the published figures. The quote states a maximum output of 1,200 kg/h; the published specific throughput times the line width gives 864 kg/h.
  • Requested output above the published maximum. The requested output of 1,000 kg/h is above 864 kg/h, the published maximum specific throughput times the line width; a person should check it against the beam layout.

4. RF5 spunbond line: The agent resubmits after fixing the errors

The agent's request. Please quote a Reicofil RF5 Spunbond line 3,200 mm wide with 3 spunbond beams, a basis weight of 15 g/m² and a conveyor speed of 1,000 m/min, in PP, with High Loft. The customer needs 1,000 kg/h. It is ready to send.

Verdict: Needs approval.

  • Requested output above the published maximum. The requested output of 1,000 kg/h is above 864 kg/h, the published maximum specific throughput times the line width; a person should check it against the beam layout.
  • Quote summary. 3,200 mm wide; published maximum specific throughput 270 kg/h/m gives 864 kg/h; requested output 1,000 kg/h; 3 spunbond beams and 0 meltblown beams.

5. RF5 spunbond line: The agent resubmits after fixing the errors

The agent's request. Please quote a Reicofil RF5 Spunbond line 3,200 mm wide with 3 spunbond beams, a basis weight of 15 g/m² and a conveyor speed of 1,000 m/min, in PP, with High Loft. The customer needs 800 kg/h. It is ready to send.

Verdict: Allowed.

  • Quote summary. 3,200 mm wide; published maximum specific throughput 270 kg/h/m gives 864 kg/h; requested output 800 kg/h; 3 spunbond beams and 0 meltblown beams.

6. Meltblown line: RF Meltblown with three beams and an unlisted width

The agent's request. Please quote a Reicofil RF Meltblown line 2,000 mm wide with 3 meltblown beams (multirow), in PP, with High Loft, with the charging unit. The customer needs 250 kg/h, and the quote states a maximum output of 300 kg/h for the line. It is ready to send.

Verdict: Blocked.

  • Beam configuration not offered. 0 spunbond beams and 3 meltblown beams is outside the published configurations for this line family.
  • Meltblown width on request. A width of 2,000 mm is not in the published meltblown list of 1000, 1600, 2,400 and 3,200 mm; the page says other widths are on request, so a person should confirm it.
  • Loft option not listed for this line. The selected loft option is not listed in the published data for this line family; a person should confirm it is offered.

7. Meltblown line: The agent resubmits after fixing the errors

The agent's request. Please quote a Reicofil RF Meltblown line 2,400 mm wide with 2 meltblown beams (multirow), in PP, with the charging unit. The customer needs 300 kg/h, and the quote states a maximum output of 360 kg/h for the line. It is ready to send.

Verdict: Allowed.

  • Quote summary. 2,400 mm wide; published maximum specific throughput 150 kg/h/m gives 360 kg/h; requested output 300 kg/h; 0 spunbond beams and 2 meltblown beams.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares a quote for a nonwovens producer that wants a Reicofil spunbond, composite or meltblown line: the line family, the width, the beam configuration, and more. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published line data and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote a Reicofil RF Smart Composite line 4,200 mm wide with 2 spunbond beams and 1 meltblown beam, a basis weight of 5 g/m² and a conveyor speed of 900 m/min. The customer needs 400 kg/h, and the quote states a maximum output of 756 kg/h for the line. The rest of the request is on screen.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with three findings, all in one answer. A line width of 4,200 mm is not one of the published widths for this line family. A basis weight of 5 g/m² is outside the published range of 8 to 70 g/m² for this line. A conveyor speed of 900 m/min is above the published maximum of 800 m/min for this line family.
  6. The validator returned three blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for widths that differ by line family, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the line width to 3,200 mm, the basis weight to 20, the conveyor speed to 800 m/min and the stated maximum output to 576 kg/h.
  10. It calls the validator again.
  11. This time the validator clears it.
  12. All three earlier findings are cleared, and the validator's figure matches the quote.
  13. Three problems caught in one call, fixed in one pass, and a clean quote. That is the value of Predictika's validator: catching mistakes before they reach the customer. Now you can try the other scenarios yourself.